[Establishment and preliminary clinical validation of an artificial intelligence-assisted perforator identification model for anterolateral thigh perforator flaps based on ICGA videos].

X W Hou, S Dong, B Zhu, C L Wu, Y S Tian, S Wang, Z Y Liu, J H Ju, K Wang
{"title":"[Establishment and preliminary clinical validation of an artificial intelligence-assisted perforator identification model for anterolateral thigh perforator flaps based on ICGA videos].","authors":"X W Hou, S Dong, B Zhu, C L Wu, Y S Tian, S Wang, Z Y Liu, J H Ju, K Wang","doi":"10.3760/cma.j.cn501225-20260531-00222","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To establish and preliminarily clinical validate an artificial intelligence-assisted perforator identification model for anterolateral thigh perforator flaps based on indocyanine green angiography (ICGA) videos. <b>Methods:</b> This study was a cross-sectional study. From January to July 2024, 70 patients who met the inclusion criteria and underwent anterolateral thigh perforator flap repair surgery were admitted to Suzhou Ruihua Orthopedic Hospital of Soochow University. There were 54 males and 16 females, aged 10 to 70 years. Fifty patients were selected as the training set for model parameter training using the random function in Python 3.13, and the remaining 20 patients were assigned as the validation set for independent validation. All patients received preoperative color Doppler ultrasound (CDU) and ICGA examinations. Postoperatively, artificial intelligence-assisted identification based on ICGA videos was adopted for perforator localization. Four perforator sites were designated in the anterolateral thigh perforator flap area of each patient. In the training set and the validation set of patients, the positive in perforator localization of CDU, ICGA-manual interpretation, and artificial intelligence-assisted ICGA (ICGA-AI) was collected, and the positive rate was calculated. The sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and balanced accuracy of the three methods for perforator localization were calculated; the consistency of the perforator localization results between the three methods and the intraoperative exploration was recorded. The distance between the perforator localization points determined by the three methods and the corresponding actual intraoperative cutaneous perforator entry point (error distance of perforator localization) was measured. The consistency between the dominant perforator localized by ICGA-AI and that determined intraoperatively was recorded, and the localization accuracy of the dominant perforator was calculated. <b>Results:</b> There were no statistically significant differences in the positive rates of perforator localization among the three methods in both the training set and the validation set of patients (<i>P</i>>0.05). In the training set of patients, the sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and balanced accuracy for perforator localization were 88.70%, 85.88%, 89.47%, 84.88%, 87.50%, and 87.29% for CDU, 93.91%, 89.41%, 92.31%, 91.57%, 92.00%, and 91.66% for ICGA-manual interpretation, and 82.61%, 83.53%, 87.16%, 78.02%, 83.00%, and 83.07% for ICGA-AI, respectively; the consistency between the perforator localization results by CDU, ICGA-manual interpretation, and ICGA-AI and the findings from intraoperative exploration was strong or almost perfect (with <i>κ</i> of 0.74, 0.84, and 0.66, respectively, <i>P</i><0.05). In the validation set of patients, the sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and balanced accuracy for perforator localization were 95.24%, 78.95%, 83.33%, 93.75%, 87.50%, and 87.09% for CDU, 95.24%, 92.11%, 93.02%, 94.59%, 93.75%, and 93.67% for ICGA-manual interpretation, and 95.24%, 94.74%, 95.24%, 94.74%, 95.00%, and 94.99% for ICGA-AI, respectively; the consistency between the perforator localization results by CDU, ICGA-manual interpretation, and ICGA-AI and the findings from intraoperative exploration was strong or almost perfect (with <i>κ</i> of 0.75, 0.88, and 0.90, respectively, <i>P</i><0.05). In the training set of patients, the error distance of perforator localization of ICGA-AI was 0.84 (0.70, 0.98) cm, which was significantly shorter than 1.41 (0.80, 2.00) cm of CDU (<i>Z</i>=-2.56, <i>P</i><0.05) and 1.50 (1.03, 1.80) cm of ICGA-manual interpretation (<i>Z</i>=-5.88, <i>P</i><0.05). In the validation set of patients, the error distance of perforator localization of ICGA-AI was 0.52 (0.35, 0.71) cm, which was significantly shorter than 1.50 (1.00, 2.25) cm of CDU (<i>Z</i>=-3.23, <i>P</i><0.05) and 1.56 (1.41, 2.00) cm of ICGA-manual interpretation (<i>Z</i>=-3.52, <i>P</i><0.05). In the training set and the validation set of patients, the localization accuracy of ICGA-AI for the dominant perforator was 82.00% (41/50) and 90.00% (18/20), respectively. <b>Conclusions:</b> An artificial intelligence-assisted perforator identification model for anterolateral thigh perforator flaps based on ICGA videos is established. In patients of the validation set, this model shows smaller localization errors and higher accuracy in locating dominant perforators, which can assist with preoperative perforator localization.</p>","PeriodicalId":516861,"journal":{"name":"Zhonghua shao shang yu chuang mian xiu fu za zhi","volume":"42 9","pages":"837-846"},"PeriodicalIF":0.0000,"publicationDate":"2026-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13654638/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua shao shang yu chuang mian xiu fu za zhi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3760/cma.j.cn501225-20260531-00222","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To establish and preliminarily clinical validate an artificial intelligence-assisted perforator identification model for anterolateral thigh perforator flaps based on indocyanine green angiography (ICGA) videos. Methods: This study was a cross-sectional study. From January to July 2024, 70 patients who met the inclusion criteria and underwent anterolateral thigh perforator flap repair surgery were admitted to Suzhou Ruihua Orthopedic Hospital of Soochow University. There were 54 males and 16 females, aged 10 to 70 years. Fifty patients were selected as the training set for model parameter training using the random function in Python 3.13, and the remaining 20 patients were assigned as the validation set for independent validation. All patients received preoperative color Doppler ultrasound (CDU) and ICGA examinations. Postoperatively, artificial intelligence-assisted identification based on ICGA videos was adopted for perforator localization. Four perforator sites were designated in the anterolateral thigh perforator flap area of each patient. In the training set and the validation set of patients, the positive in perforator localization of CDU, ICGA-manual interpretation, and artificial intelligence-assisted ICGA (ICGA-AI) was collected, and the positive rate was calculated. The sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and balanced accuracy of the three methods for perforator localization were calculated; the consistency of the perforator localization results between the three methods and the intraoperative exploration was recorded. The distance between the perforator localization points determined by the three methods and the corresponding actual intraoperative cutaneous perforator entry point (error distance of perforator localization) was measured. The consistency between the dominant perforator localized by ICGA-AI and that determined intraoperatively was recorded, and the localization accuracy of the dominant perforator was calculated. Results: There were no statistically significant differences in the positive rates of perforator localization among the three methods in both the training set and the validation set of patients (P>0.05). In the training set of patients, the sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and balanced accuracy for perforator localization were 88.70%, 85.88%, 89.47%, 84.88%, 87.50%, and 87.29% for CDU, 93.91%, 89.41%, 92.31%, 91.57%, 92.00%, and 91.66% for ICGA-manual interpretation, and 82.61%, 83.53%, 87.16%, 78.02%, 83.00%, and 83.07% for ICGA-AI, respectively; the consistency between the perforator localization results by CDU, ICGA-manual interpretation, and ICGA-AI and the findings from intraoperative exploration was strong or almost perfect (with κ of 0.74, 0.84, and 0.66, respectively, P<0.05). In the validation set of patients, the sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and balanced accuracy for perforator localization were 95.24%, 78.95%, 83.33%, 93.75%, 87.50%, and 87.09% for CDU, 95.24%, 92.11%, 93.02%, 94.59%, 93.75%, and 93.67% for ICGA-manual interpretation, and 95.24%, 94.74%, 95.24%, 94.74%, 95.00%, and 94.99% for ICGA-AI, respectively; the consistency between the perforator localization results by CDU, ICGA-manual interpretation, and ICGA-AI and the findings from intraoperative exploration was strong or almost perfect (with κ of 0.75, 0.88, and 0.90, respectively, P<0.05). In the training set of patients, the error distance of perforator localization of ICGA-AI was 0.84 (0.70, 0.98) cm, which was significantly shorter than 1.41 (0.80, 2.00) cm of CDU (Z=-2.56, P<0.05) and 1.50 (1.03, 1.80) cm of ICGA-manual interpretation (Z=-5.88, P<0.05). In the validation set of patients, the error distance of perforator localization of ICGA-AI was 0.52 (0.35, 0.71) cm, which was significantly shorter than 1.50 (1.00, 2.25) cm of CDU (Z=-3.23, P<0.05) and 1.56 (1.41, 2.00) cm of ICGA-manual interpretation (Z=-3.52, P<0.05). In the training set and the validation set of patients, the localization accuracy of ICGA-AI for the dominant perforator was 82.00% (41/50) and 90.00% (18/20), respectively. Conclusions: An artificial intelligence-assisted perforator identification model for anterolateral thigh perforator flaps based on ICGA videos is established. In patients of the validation set, this model shows smaller localization errors and higher accuracy in locating dominant perforators, which can assist with preoperative perforator localization.

[基于ICGA视频的股前外侧穿支皮瓣人工智能辅助穿支识别模型的建立及初步临床验证]
目的:建立基于吲哚菁绿血管造影(ICGA)视频的人工智能辅助股前外侧穿支皮瓣识别模型并进行初步临床验证。方法:本研究为横断面研究。2024年1月至7月,苏州大学苏州瑞华骨科医院收治了70例符合纳入标准并行股前外侧穿支皮瓣修复术的患者。男性54例,女性16例,年龄10 ~ 70岁。选择50例患者作为训练集,使用Python 3.13中的随机函数进行模型参数训练,其余20例患者作为验证集进行独立验证。所有患者术前均行彩色多普勒超声(CDU)和ICGA检查。术后采用基于ICGA视频的人工智能辅助识别进行穿支定位。在每位患者的大腿前外侧穿支皮瓣区指定4个穿支点。在患者的训练集和验证集中,收集CDU穿支定位、ICGA-人工解释和人工智能辅助ICGA (ICGA- ai)的阳性结果,并计算阳性率。计算三种方法对射孔器定位的敏感性、特异性、阳性预测值、阴性预测值、准确度和平衡准确度;记录三种方法的穿支定位结果与术中探查的一致性。测量三种方法确定的穿支定位点与术中相应皮肤穿支实际进入点(穿支定位误差距离)之间的距离。记录ICGA-AI定位的优势穿支与术中确定的优势穿支的一致性,计算优势穿支的定位精度。结果:三种方法在患者训练集和验证集的穿支定位阳性率比较,差异均无统计学意义(P < 0.05)。在患者训练集中,CDU对穿支定位的敏感性、特异性、阳性预测值、阴性预测值、准确率和平衡准确率分别为88.70%、85.88%、89.47%、84.88%、87.50%、87.29%,icga -人工解释的敏感性、特异性、阳性预测值、阴性预测值、准确率分别为93.91%、89.41%、92.31%、91.57%、92.00%、91.66%,ICGA-AI的敏感性、83.53%、87.16%、78.02%、83.00%、83.07%;CDU、ICGA-人工解译、ICGA- ai对穿支定位结果与术中探查结果的一致性较强或接近完美(κ分别为0.74、0.84、0.66,Pκ分别为0.75、0.88、0.90,PZ=-2.56、PZ=-5.88、PZ=-3.23、PZ=-3.52、PZ)。结论:建立了基于ICGA视频的人工智能辅助大腿前外侧穿支皮瓣穿支识别模型。在验证集的患者中,该模型定位误差较小,定位优势穿支精度较高,有助于术前穿支定位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书