{"title":"Potential Overestimation of Uveoscleral Outflow from Goldmann Tonometry Bias.","authors":"Sean McCafferty","doi":"10.2147/OPTH.S638576","DOIUrl":null,"url":null,"abstract":"<p><p>In living humans, uveoscleral outflow (Fu) is calculated, not measured. Except in rare tracer studies it is the residual of the modified Goldmann equation, Fu = F - C(IOP - Pev), which treats Fu as pressure-independent and assigns all pressure-dependent outflow to facility (C). Goldmann applanation tonometry (GAT) underestimates manometric IOP by about 4-5 mmHg. Because F, C, and Pev are measured independently of GAT, that low IOP input understates C(IOP - Pev) and overstates the residual reported as pressure-independent uveoscleral outflow. With representative values, GAT 15.5 mmHg yields Fu of about 50% of flow; manometric 20 mmHg yields about 9%, in line with human tracer data. A pressure-dependent uveoscleral component, if present, already sits inside C and cannot be separated by this method. The same bias has likely overstated the pressure-independent effect of prostaglandin analogs.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":"20 ","pages":"638576"},"PeriodicalIF":0.0000,"publicationDate":"2026-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13620411/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S638576","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In living humans, uveoscleral outflow (Fu) is calculated, not measured. Except in rare tracer studies it is the residual of the modified Goldmann equation, Fu = F - C(IOP - Pev), which treats Fu as pressure-independent and assigns all pressure-dependent outflow to facility (C). Goldmann applanation tonometry (GAT) underestimates manometric IOP by about 4-5 mmHg. Because F, C, and Pev are measured independently of GAT, that low IOP input understates C(IOP - Pev) and overstates the residual reported as pressure-independent uveoscleral outflow. With representative values, GAT 15.5 mmHg yields Fu of about 50% of flow; manometric 20 mmHg yields about 9%, in line with human tracer data. A pressure-dependent uveoscleral component, if present, already sits inside C and cannot be separated by this method. The same bias has likely overstated the pressure-independent effect of prostaglandin analogs.