Rui Zhao, Ying Liu, Shen Han, Xiaochen Qin, Sawab Deen Osseni, Ruixuan An, Zhiyi Yao
{"title":"Ratiometric Fluorescence Sensing of Aflatoxin B1 Using a Cationic Perylene Probe and Rhodamine B.","authors":"Rui Zhao, Ying Liu, Shen Han, Xiaochen Qin, Sawab Deen Osseni, Ruixuan An, Zhiyi Yao","doi":"10.1007/s10895-026-04938-7","DOIUrl":null,"url":null,"abstract":"<p><p>As one of the most toxic and prevalent mycotoxins, aflatoxin B<sub>1</sub> (AFB<sub>1</sub>) poses a persistent threat to food safety and public health due to its widespread contamination of cereal commodities and its well-documented carcinogenic, genotoxic, and hepatotoxic effects. Although fluorescence sensing provides a rapid approach to AFB<sub>1</sub> screening, most existing fluorescence strategies rely on antibodies or aptamers, which are costly, laborious, and susceptible to environmental degradation; moreover, single-emission readouts remain vulnerable to variations in probe concentration, excitation conditions, and sample background. Herein, we developed a simple two-fluorophore, antibody- and aptamer-free ratiometric fluorescence system that pairs the AFB<sub>1</sub>-responsive perylene derivative PTHA with Rhodamine B (RhB) as a reference fluorophore to afford a single-excitation, dual-emission readout. The system produced a concentration-dependent ratiometric signal over the linear range of 1-20 µg mL<sup>-1</sup>, with an estimated statistical detection limit of 0.0165 µg mL<sup>-1</sup>. It produced a substantially greater response to AFB<sub>1</sub> than to the tested mycotoxins and other potential interferents, indicating preliminary discrimination among the substances examined. The absorption changes and nearly unchanged fluorescence lifetime were consistent with predominantly static or static-like fluorescence attenuation involving ground-state association and possible redistribution of PTHA toward weakly emissive aggregated states. The performance of the method was evaluated in AFB<sub>1</sub>-spiked rice, maize, and millet extracts, yielding recoveries of 91.5-109.0% and relative standard deviations of 1.2-3.6%. These results support the proof-of-concept use of the PTHA/RhB system for ratiometric determination of relatively high AFB<sub>1</sub> levels in pretreated cereal extracts.</p>","PeriodicalId":15800,"journal":{"name":"Journal of Fluorescence","volume":" ","pages":"6055-6065"},"PeriodicalIF":3.4000,"publicationDate":"2026-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Fluorescence","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s10895-026-04938-7","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/29 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
As one of the most toxic and prevalent mycotoxins, aflatoxin B1 (AFB1) poses a persistent threat to food safety and public health due to its widespread contamination of cereal commodities and its well-documented carcinogenic, genotoxic, and hepatotoxic effects. Although fluorescence sensing provides a rapid approach to AFB1 screening, most existing fluorescence strategies rely on antibodies or aptamers, which are costly, laborious, and susceptible to environmental degradation; moreover, single-emission readouts remain vulnerable to variations in probe concentration, excitation conditions, and sample background. Herein, we developed a simple two-fluorophore, antibody- and aptamer-free ratiometric fluorescence system that pairs the AFB1-responsive perylene derivative PTHA with Rhodamine B (RhB) as a reference fluorophore to afford a single-excitation, dual-emission readout. The system produced a concentration-dependent ratiometric signal over the linear range of 1-20 µg mL-1, with an estimated statistical detection limit of 0.0165 µg mL-1. It produced a substantially greater response to AFB1 than to the tested mycotoxins and other potential interferents, indicating preliminary discrimination among the substances examined. The absorption changes and nearly unchanged fluorescence lifetime were consistent with predominantly static or static-like fluorescence attenuation involving ground-state association and possible redistribution of PTHA toward weakly emissive aggregated states. The performance of the method was evaluated in AFB1-spiked rice, maize, and millet extracts, yielding recoveries of 91.5-109.0% and relative standard deviations of 1.2-3.6%. These results support the proof-of-concept use of the PTHA/RhB system for ratiometric determination of relatively high AFB1 levels in pretreated cereal extracts.
期刊介绍:
Journal of Fluorescence is an international forum for the publication of peer-reviewed original articles that advance the practice of this established spectroscopic technique. Topics covered include advances in theory/and or data analysis, studies of the photophysics of aromatic molecules, solvent, and environmental effects, development of stationary or time-resolved measurements, advances in fluorescence microscopy, imaging, photobleaching/recovery measurements, and/or phosphorescence for studies of cell biology, chemical biology and the advanced uses of fluorescence in flow cytometry/analysis, immunology, high throughput screening/drug discovery, DNA sequencing/arrays, genomics and proteomics. Typical applications might include studies of macromolecular dynamics and conformation, intracellular chemistry, and gene expression. The journal also publishes papers that describe the synthesis and characterization of new fluorophores, particularly those displaying unique sensitivities and/or optical properties. In addition to original articles, the Journal also publishes reviews, rapid communications, short communications, letters to the editor, topical news articles, and technical and design notes.