Aseptic loosening of small hydroxyapatite-coated quadrangular tapered femoral stems: camouflage in the Canadian Joint Replacement Registry.

IF 1.3 4区 医学 Q3 ORTHOPEDICS
Christiaan H Righolt, Colton Poitras, Rohit Bansal, Colin D Burnell, Thomas R Turgeon, Eric R Bohm
{"title":"Aseptic loosening of small hydroxyapatite-coated quadrangular tapered femoral stems: camouflage in the Canadian Joint Replacement Registry.","authors":"Christiaan H Righolt, Colton Poitras, Rohit Bansal, Colin D Burnell, Thomas R Turgeon, Eric R Bohm","doi":"10.1177/11207000261475482","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Small cementless hydroxyapatite-coated quadrangular tapered femoral stems are at increased risk of revision, but it is unclear whether this holds for appropriately-sized and undersized stems alike. This study aimed to assess the association between stem size and revisions for aseptic loosening.</p><p><strong>Methods: </strong>Primary total hip arthroplasties with an Avenir (1547; Zimmer-Biomet), Corail (16,893; DePuy Synthes), or Polarstem (3403; Smith+Nephew) stem during 2012-2023 were identified from the Canadian Joint Replacement Registry. Cox proportional hazards models were used to estimate the association between stem/cup size and revision for aseptic loosening while adjusting for age, sex, and implant characteristics. Standardised stem sizing from A-K (smallest-largest) was utilised.</p><p><strong>Results: </strong>Between different stems, the proportion of size A was 1.2-5.0% and of size B 3.6-12.2%. ⅓ (21/63) of aseptic loosening revisions occurred for size A/B. Increased risk of revision for aseptic loosening for size A stems was found with a hazard ratio (HR) of 46 (95% CI, 9-226) when paired with ⩾56-mm cups, 47 (14-157) when paired with 52-54-mm cups, and 17 (4-78) when paired with ⩽50-mm cups (reference size C+ with ⩾56-mm cups). Size B stems were also at increased risk of aseptic loosening, with an HR of 15 (95% CI, 4-52) and 9 (95% CI, 3-32) for ⩾56 and 52-54-mm cups respectively.</p><p><strong>Conclusions: </strong>The increased risk of revision of these small stems camouflages a highly increased risk of revision for aseptic loosening in undersized stems (small stem/big cup). This study was unable to ascertain whether this applies to other quadrangular tapered stems. Due to the small number of affected patients, it is important to repeat this study in other jurisdictions. Surgeons should be skeptical if a smaller size stem seems appropriate during broaching than preoperative templating or cup size suggests, as this may increase the risk of aseptic loosening.</p>","PeriodicalId":12911,"journal":{"name":"HIP International","volume":" ","pages":"11207000261475482"},"PeriodicalIF":1.3000,"publicationDate":"2026-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"HIP International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11207000261475482","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Small cementless hydroxyapatite-coated quadrangular tapered femoral stems are at increased risk of revision, but it is unclear whether this holds for appropriately-sized and undersized stems alike. This study aimed to assess the association between stem size and revisions for aseptic loosening.

Methods: Primary total hip arthroplasties with an Avenir (1547; Zimmer-Biomet), Corail (16,893; DePuy Synthes), or Polarstem (3403; Smith+Nephew) stem during 2012-2023 were identified from the Canadian Joint Replacement Registry. Cox proportional hazards models were used to estimate the association between stem/cup size and revision for aseptic loosening while adjusting for age, sex, and implant characteristics. Standardised stem sizing from A-K (smallest-largest) was utilised.

Results: Between different stems, the proportion of size A was 1.2-5.0% and of size B 3.6-12.2%. ⅓ (21/63) of aseptic loosening revisions occurred for size A/B. Increased risk of revision for aseptic loosening for size A stems was found with a hazard ratio (HR) of 46 (95% CI, 9-226) when paired with ⩾56-mm cups, 47 (14-157) when paired with 52-54-mm cups, and 17 (4-78) when paired with ⩽50-mm cups (reference size C+ with ⩾56-mm cups). Size B stems were also at increased risk of aseptic loosening, with an HR of 15 (95% CI, 4-52) and 9 (95% CI, 3-32) for ⩾56 and 52-54-mm cups respectively.

Conclusions: The increased risk of revision of these small stems camouflages a highly increased risk of revision for aseptic loosening in undersized stems (small stem/big cup). This study was unable to ascertain whether this applies to other quadrangular tapered stems. Due to the small number of affected patients, it is important to repeat this study in other jurisdictions. Surgeons should be skeptical if a smaller size stem seems appropriate during broaching than preoperative templating or cup size suggests, as this may increase the risk of aseptic loosening.

小羟基磷灰石包覆的四边形锥形股骨干的无菌松动:伪装在加拿大关节置换术登记。
背景:小的无水泥羟基磷灰石包覆的四边形锥形股骨干翻修的风险增加,但尚不清楚这是否适用于适当大小和不足大小的股骨干。本研究旨在评估茎杆尺寸与无菌松动修复之间的关系。方法:2012-2023年间,从加拿大关节置换登记中心(Canadian Joint Replacement Registry)中确定了使用Avenir(1547例;zimmero - biomet)、Corail(16893例;DePuy Synthes)或Polarstem(3403例;Smith+Nephew)假体进行的原发性全髋关节置换术。在调整年龄、性别和植入物特征的同时,使用Cox比例风险模型来估计柄/杯大小与无菌松动翻修之间的关系。采用A-K(最小-最大)标准阀杆通径。结果:不同茎段间,A粒所占比例为1.2 ~ 5.0%,B粒所占比例为3.6 ~ 12.2%。1/ 3(21/63)的无菌松动修复发生在尺寸A/B。当与大于或等于56毫米的杯子配对时,发现A尺寸的干的无菌松动翻修的风险增加,风险比(HR)为46 (95% CI, 9-226),与52-54毫米的杯子配对时为47(14-157),与≥50毫米的杯子配对时为17(4-78)(参考尺寸C+与大于或等于56毫米的杯子)。对于大于或等于56和大于或等于52-54毫米的罩杯,B号罩杯无菌性松动的风险也增加,HR分别为15 (95% CI, 4-52)和9 (95% CI, 3-32)。结论:这些小柄的翻修风险增加掩盖了小柄(小柄/大杯)无菌性松动翻修风险的高度增加。这项研究无法确定这是否适用于其他四边形锥形茎。由于受影响的患者数量较少,在其他司法管辖区重复这项研究很重要。外科医生应该怀疑在拉拔过程中使用比术前模板或罩杯尺寸更小的柄是否合适,因为这可能会增加无菌性松动的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
HIP International
HIP International 医学-整形外科
CiteScore
4.20
自引率
0.00%
发文量
70
审稿时长
2 months
期刊介绍: HIP International is the official journal of the European Hip Society. It is the only international, peer-reviewed, bi-monthly journal dedicated to diseases of the hip. HIP International considers contributions relating to hip surgery, traumatology of the hip, prosthetic surgery, biomechanics, and basic sciences relating to the hip. HIP International invites reviews from leading specialists with the aim of informing its readers of current evidence-based best practice. The journal also publishes supplements containing proceedings of symposia, special meetings or articles of special educational merit. HIP International is divided into six independent sections led by editors of the highest scientific merit. These sections are: • Biomaterials • Biomechanics • Conservative Hip Surgery • Paediatrics • Primary and Revision Hip Arthroplasty • Traumatology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书