High-sensitivity NIR Blood Analyte Sensing Using a Double-sefect 1D Photonic Crystal: A Comparative TMM and FEM Investigation

IF 5.6 4区 物理与天体物理 Q2 CHEMISTRY, PHYSICAL
Vipin Kumar, Neeraj Kumar,  Himanshu, Rishabh Tyagi, Chhavi Tomar
{"title":"High-sensitivity NIR Blood Analyte Sensing Using a Double-sefect 1D Photonic Crystal: A Comparative TMM and FEM Investigation","authors":"Vipin Kumar,&nbsp;Neeraj Kumar,&nbsp; Himanshu,&nbsp;Rishabh Tyagi,&nbsp;Chhavi Tomar","doi":"10.1007/s11468-026-03444-7","DOIUrl":null,"url":null,"abstract":"<div><p>In the present work, a symmetric one-dimensional (1D) Silicon/Silicon Dioxide double-defect photonic crystal biosensor for high-resolution blood component screening in the near-infrared (NIR) regime has been proposed. The proposed structure, optimized for a central design wavelength of 1550 nm, is represented as <span>\\(\\mathrm{Air}/\\left(\\mathrm{BA}\\right)^N-\\mathrm B-\\mathrm D-\\mathrm B-\\mathrm D\\left(\\mathrm{BA}\\right)^N-\\mathrm B/\\mathrm{Air}\\)</span>, where A and B represent Silicon Dioxide and Silicon layers, respectively, and D denotes identical microfluidic defect cavities containing blood analytes. The transmission spectra and localized electric field confinement profiles are rigorously modelled and validated using the Transfer Matrix Method (TMM) and a 1D Finite Element Method (FEM) Helmholtz solver. Due to electromagnetic state hybridization in the coupled defect cavities, the transmission spectrum exhibits split resonance modes (Peak 1 and Peak 2) inside the photonic bandgap. Under normal incidence θ = 0<sup>0</sup> with a period <i>N</i> = 7, the sensor achieves a high refractive index sensitivity of up to 544.14 nm/RIU for Hemoglobin, extremely narrow linewidths (FWHM down to 5.08 pm), and Quality Factors (Q) up to 2.76 × 10<sup>5</sup> for Plasma, resulting in a Limit of Detection (LoD) in the order of 10<sup>− 6</sup> RIU. The transition to extreme oblique angles of incidence (up to 80<sup>0</sup>) significantly elongates the optical path length through the cavity defects, enhancing the peak sensitivity to 784.18 nm/RIU and narrowing the resonance FWHM to sub-picometer levels 0.25 pm, which yields an ultra-high-Quality Factor of 5.32 × 10<sup>6</sup> and a Figure of Merit (<span>\\(\\:\\text{FoM}\\)</span>) of 3.12 × 10<sup>6</sup> RIU<sup>− 1</sup> for the Plasma component. The comparative analysis shows perfect agreement between TMM and FEM calculations, with minor resonance peak shifts (+ 50 to + 90 pm) arising from finite-element discretization grid rounding, and peak shift discrepancies of less than 5 pm, validating the numerical consistency of the model. These results demonstrate that the proposed symmetric double-defect configuration represents a highly sensitive, and stable optical platform for rapid NIR blood diagnostics.</p></div>","PeriodicalId":736,"journal":{"name":"Plasmonics","volume":"21 9","pages":"3729 - 3747"},"PeriodicalIF":5.6000,"publicationDate":"2026-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plasmonics","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s11468-026-03444-7","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In the present work, a symmetric one-dimensional (1D) Silicon/Silicon Dioxide double-defect photonic crystal biosensor for high-resolution blood component screening in the near-infrared (NIR) regime has been proposed. The proposed structure, optimized for a central design wavelength of 1550 nm, is represented as \(\mathrm{Air}/\left(\mathrm{BA}\right)^N-\mathrm B-\mathrm D-\mathrm B-\mathrm D\left(\mathrm{BA}\right)^N-\mathrm B/\mathrm{Air}\), where A and B represent Silicon Dioxide and Silicon layers, respectively, and D denotes identical microfluidic defect cavities containing blood analytes. The transmission spectra and localized electric field confinement profiles are rigorously modelled and validated using the Transfer Matrix Method (TMM) and a 1D Finite Element Method (FEM) Helmholtz solver. Due to electromagnetic state hybridization in the coupled defect cavities, the transmission spectrum exhibits split resonance modes (Peak 1 and Peak 2) inside the photonic bandgap. Under normal incidence θ = 00 with a period N = 7, the sensor achieves a high refractive index sensitivity of up to 544.14 nm/RIU for Hemoglobin, extremely narrow linewidths (FWHM down to 5.08 pm), and Quality Factors (Q) up to 2.76 × 105 for Plasma, resulting in a Limit of Detection (LoD) in the order of 10− 6 RIU. The transition to extreme oblique angles of incidence (up to 800) significantly elongates the optical path length through the cavity defects, enhancing the peak sensitivity to 784.18 nm/RIU and narrowing the resonance FWHM to sub-picometer levels 0.25 pm, which yields an ultra-high-Quality Factor of 5.32 × 106 and a Figure of Merit (\(\:\text{FoM}\)) of 3.12 × 106 RIU− 1 for the Plasma component. The comparative analysis shows perfect agreement between TMM and FEM calculations, with minor resonance peak shifts (+ 50 to + 90 pm) arising from finite-element discretization grid rounding, and peak shift discrepancies of less than 5 pm, validating the numerical consistency of the model. These results demonstrate that the proposed symmetric double-defect configuration represents a highly sensitive, and stable optical platform for rapid NIR blood diagnostics.

双选一维光子晶体高灵敏度近红外血液分析物传感:TMM和FEM的比较研究
在目前的工作中,提出了一种对称的一维(1D)硅/二氧化硅双缺陷光子晶体生物传感器,用于近红外(NIR)区域的高分辨率血液成分筛选。所提出的结构以1550 nm为中心设计波长进行优化,用\(\mathrm{Air}/\left(\mathrm{BA}\right)^N-\mathrm B-\mathrm D-\mathrm B-\mathrm D\left(\mathrm{BA}\right)^N-\mathrm B/\mathrm{Air}\)表示,其中a和B分别代表二氧化硅和硅层,D表示含有血液分析物的相同微流控缺陷腔。利用传递矩阵法(TMM)和一维有限元(FEM)亥姆霍兹求解器对透射光谱和局域电场约束剖面进行了严格的建模和验证。由于耦合缺陷腔中的电磁态杂化,透射谱在光子带隙内呈现出分裂共振模式(峰1和峰2)。在正常入射θ = 00,周期N = 7的情况下,该传感器对血红蛋白的折射率灵敏度高达544.14 nm/RIU,线宽极窄(FWHM低至5.08 pm),对血浆的质量因子(Q)高达2.76 × 105,检测限(LoD)约为10−6 RIU。过渡到极端斜入射角(高达800)显着延长了通过腔缺陷的光路长度,将峰值灵敏度提高到784.18 nm/RIU,并将共振FWHM缩小到亚皮米水平0.25 pm,从而产生了5.32 × 106的超高质量因子和3.12 × 106 RIU−1的品质系数(\(\:\text{FoM}\))。对比分析表明,TMM和FEM计算结果吻合较好,有限元离散网格舍入引起的共振峰移较小(+ 50 ~ + 90pm),峰移差异小于5pm,验证了模型的数值一致性。这些结果表明,所提出的对称双缺陷结构为快速近红外血液诊断提供了一个高灵敏度、稳定的光学平台。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Plasmonics
Plasmonics 工程技术-材料科学:综合
CiteScore
5.90
自引率
6.70%
发文量
164
审稿时长
2.1 months
期刊介绍: Plasmonics is an international forum for the publication of peer-reviewed leading-edge original articles that both advance and report our knowledge base and practice of the interactions of free-metal electrons, Plasmons. Topics covered include notable advances in the theory, Physics, and applications of surface plasmons in metals, to the rapidly emerging areas of nanotechnology, biophotonics, sensing, biochemistry and medicine. Topics, including the theory, synthesis and optical properties of noble metal nanostructures, patterned surfaces or materials, continuous or grated surfaces, devices, or wires for their multifarious applications are particularly welcome. Typical applications might include but are not limited to, surface enhanced spectroscopic properties, such as Raman scattering or fluorescence, as well developments in techniques such as surface plasmon resonance and near-field scanning optical microscopy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书