{"title":"High-sensitivity NIR Blood Analyte Sensing Using a Double-sefect 1D Photonic Crystal: A Comparative TMM and FEM Investigation","authors":"Vipin Kumar, Neeraj Kumar, Himanshu, Rishabh Tyagi, Chhavi Tomar","doi":"10.1007/s11468-026-03444-7","DOIUrl":null,"url":null,"abstract":"<div><p>In the present work, a symmetric one-dimensional (1D) Silicon/Silicon Dioxide double-defect photonic crystal biosensor for high-resolution blood component screening in the near-infrared (NIR) regime has been proposed. The proposed structure, optimized for a central design wavelength of 1550 nm, is represented as <span>\\(\\mathrm{Air}/\\left(\\mathrm{BA}\\right)^N-\\mathrm B-\\mathrm D-\\mathrm B-\\mathrm D\\left(\\mathrm{BA}\\right)^N-\\mathrm B/\\mathrm{Air}\\)</span>, where A and B represent Silicon Dioxide and Silicon layers, respectively, and D denotes identical microfluidic defect cavities containing blood analytes. The transmission spectra and localized electric field confinement profiles are rigorously modelled and validated using the Transfer Matrix Method (TMM) and a 1D Finite Element Method (FEM) Helmholtz solver. Due to electromagnetic state hybridization in the coupled defect cavities, the transmission spectrum exhibits split resonance modes (Peak 1 and Peak 2) inside the photonic bandgap. Under normal incidence θ = 0<sup>0</sup> with a period <i>N</i> = 7, the sensor achieves a high refractive index sensitivity of up to 544.14 nm/RIU for Hemoglobin, extremely narrow linewidths (FWHM down to 5.08 pm), and Quality Factors (Q) up to 2.76 × 10<sup>5</sup> for Plasma, resulting in a Limit of Detection (LoD) in the order of 10<sup>− 6</sup> RIU. The transition to extreme oblique angles of incidence (up to 80<sup>0</sup>) significantly elongates the optical path length through the cavity defects, enhancing the peak sensitivity to 784.18 nm/RIU and narrowing the resonance FWHM to sub-picometer levels 0.25 pm, which yields an ultra-high-Quality Factor of 5.32 × 10<sup>6</sup> and a Figure of Merit (<span>\\(\\:\\text{FoM}\\)</span>) of 3.12 × 10<sup>6</sup> RIU<sup>− 1</sup> for the Plasma component. The comparative analysis shows perfect agreement between TMM and FEM calculations, with minor resonance peak shifts (+ 50 to + 90 pm) arising from finite-element discretization grid rounding, and peak shift discrepancies of less than 5 pm, validating the numerical consistency of the model. These results demonstrate that the proposed symmetric double-defect configuration represents a highly sensitive, and stable optical platform for rapid NIR blood diagnostics.</p></div>","PeriodicalId":736,"journal":{"name":"Plasmonics","volume":"21 9","pages":"3729 - 3747"},"PeriodicalIF":5.6000,"publicationDate":"2026-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plasmonics","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s11468-026-03444-7","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0
Abstract
In the present work, a symmetric one-dimensional (1D) Silicon/Silicon Dioxide double-defect photonic crystal biosensor for high-resolution blood component screening in the near-infrared (NIR) regime has been proposed. The proposed structure, optimized for a central design wavelength of 1550 nm, is represented as \(\mathrm{Air}/\left(\mathrm{BA}\right)^N-\mathrm B-\mathrm D-\mathrm B-\mathrm D\left(\mathrm{BA}\right)^N-\mathrm B/\mathrm{Air}\), where A and B represent Silicon Dioxide and Silicon layers, respectively, and D denotes identical microfluidic defect cavities containing blood analytes. The transmission spectra and localized electric field confinement profiles are rigorously modelled and validated using the Transfer Matrix Method (TMM) and a 1D Finite Element Method (FEM) Helmholtz solver. Due to electromagnetic state hybridization in the coupled defect cavities, the transmission spectrum exhibits split resonance modes (Peak 1 and Peak 2) inside the photonic bandgap. Under normal incidence θ = 00 with a period N = 7, the sensor achieves a high refractive index sensitivity of up to 544.14 nm/RIU for Hemoglobin, extremely narrow linewidths (FWHM down to 5.08 pm), and Quality Factors (Q) up to 2.76 × 105 for Plasma, resulting in a Limit of Detection (LoD) in the order of 10− 6 RIU. The transition to extreme oblique angles of incidence (up to 800) significantly elongates the optical path length through the cavity defects, enhancing the peak sensitivity to 784.18 nm/RIU and narrowing the resonance FWHM to sub-picometer levels 0.25 pm, which yields an ultra-high-Quality Factor of 5.32 × 106 and a Figure of Merit (\(\:\text{FoM}\)) of 3.12 × 106 RIU− 1 for the Plasma component. The comparative analysis shows perfect agreement between TMM and FEM calculations, with minor resonance peak shifts (+ 50 to + 90 pm) arising from finite-element discretization grid rounding, and peak shift discrepancies of less than 5 pm, validating the numerical consistency of the model. These results demonstrate that the proposed symmetric double-defect configuration represents a highly sensitive, and stable optical platform for rapid NIR blood diagnostics.
期刊介绍:
Plasmonics is an international forum for the publication of peer-reviewed leading-edge original articles that both advance and report our knowledge base and practice of the interactions of free-metal electrons, Plasmons.
Topics covered include notable advances in the theory, Physics, and applications of surface plasmons in metals, to the rapidly emerging areas of nanotechnology, biophotonics, sensing, biochemistry and medicine. Topics, including the theory, synthesis and optical properties of noble metal nanostructures, patterned surfaces or materials, continuous or grated surfaces, devices, or wires for their multifarious applications are particularly welcome. Typical applications might include but are not limited to, surface enhanced spectroscopic properties, such as Raman scattering or fluorescence, as well developments in techniques such as surface plasmon resonance and near-field scanning optical microscopy.