Battery length as a moderator of classification accuracy for cognitive impairment: a Monte Carlo simulation using actuarial and Bayesian methods.

IF 2.1
Alexandra Davis
{"title":"Battery length as a moderator of classification accuracy for cognitive impairment: a Monte Carlo simulation using actuarial and Bayesian methods.","authors":"Alexandra Davis","doi":"10.1093/arclin/acag078","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This Monte Carlo simulation study examined whether neuropsychological test battery length impacts cognitive impairment classification accuracy using actuarial and Bayesian interpretive frameworks. Three hypotheses were tested: (a) longer batteries yield higher false-positive rates due to cumulative probability effects; (b) longer batteries show superior classification accuracy; and (c) abbreviated batteries have higher false-negative rates.</p><p><strong>Method: </strong>Four simulated batteries of varying length, domain coverage, and redundancy were applied to 10,000 virtual patient profiles. Sensitivity, specificity, predictive values, classification accuracy, and Bayesian post-test probabilities were evaluated across multiple prevalence conditions alongside base rates of low scores and resource demands.</p><p><strong>Results: </strong>Hypothesis 1 was supported: longer batteries produced higher base rates of low scores in healthy controls. However, applying actuarial and Bayesian frameworks prevented this from translating into inflated false-positive rates. Hypotheses 2 and 3 were not supported: abbreviated batteries maintained classification accuracy, discrimination (AUC), false-negative rates, and predictive values comparable to longer batteries. Adding tests yielded diminishing returns, reaching a psychometric plateau at approximately eight tests.</p><p><strong>Conclusions: </strong>Battery length does not meaningfully alter binary impairment classification when actuarial and Bayesian rules are applied. Brief core batteries maximize efficiency for global detection, while comprehensive batteries remain best suited for detailed cognitive profiling and differential diagnosis.</p>","PeriodicalId":520564,"journal":{"name":"Archives of clinical neuropsychology : the official journal of the National Academy of Neuropsychologists","volume":"41 7","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2026-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of clinical neuropsychology : the official journal of the National Academy of Neuropsychologists","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/arclin/acag078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This Monte Carlo simulation study examined whether neuropsychological test battery length impacts cognitive impairment classification accuracy using actuarial and Bayesian interpretive frameworks. Three hypotheses were tested: (a) longer batteries yield higher false-positive rates due to cumulative probability effects; (b) longer batteries show superior classification accuracy; and (c) abbreviated batteries have higher false-negative rates.

Method: Four simulated batteries of varying length, domain coverage, and redundancy were applied to 10,000 virtual patient profiles. Sensitivity, specificity, predictive values, classification accuracy, and Bayesian post-test probabilities were evaluated across multiple prevalence conditions alongside base rates of low scores and resource demands.

Results: Hypothesis 1 was supported: longer batteries produced higher base rates of low scores in healthy controls. However, applying actuarial and Bayesian frameworks prevented this from translating into inflated false-positive rates. Hypotheses 2 and 3 were not supported: abbreviated batteries maintained classification accuracy, discrimination (AUC), false-negative rates, and predictive values comparable to longer batteries. Adding tests yielded diminishing returns, reaching a psychometric plateau at approximately eight tests.

Conclusions: Battery length does not meaningfully alter binary impairment classification when actuarial and Bayesian rules are applied. Brief core batteries maximize efficiency for global detection, while comprehensive batteries remain best suited for detailed cognitive profiling and differential diagnosis.

电池长度作为认知障碍分类准确性的调节因素:使用精算和贝叶斯方法的蒙特卡洛模拟。
目的:本蒙特卡洛模拟研究利用精算和贝叶斯解释框架考察神经心理测试电池长度对认知障碍分类准确性的影响。测试了三个假设:(a)由于累积概率效应,更长的电池产生更高的假阳性率;(b)更长的电池显示更高的分类精度;(c)缩短电池有更高的假阴性率。方法:四个不同长度,域覆盖和冗余的模拟电池应用于10,000个虚拟患者档案。敏感性、特异性、预测值、分类准确性和贝叶斯检验后概率在多种流行情况下以及低评分和资源需求的基础率进行评估。结果:假设1得到支持:在健康对照中,较长的电池时间产生较高的低得分基础率。然而,应用精算和贝叶斯框架可以防止这种情况转化为虚高的假阳性率。假设2和3不被支持:短电池保持分类准确性、鉴别(AUC)、假阴性率和预测值与长电池相当。增加测试产生递减的回报,在大约8次测试时达到心理测量平台。结论:当应用精算和贝叶斯规则时,电池长度对二元损伤分类没有意义。简短的核心电池最大限度地提高了全球检测的效率,而全面的电池仍然最适合于详细的认知分析和鉴别诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书