{"title":"AI-enabled left atrial volume quantification from CAC CT: comparison with echocardiography.","authors":"Eshan Momin, Jaret Barr, Gabrielle Gershon, Brian Zhou, Anurag Mehta, Saikiran Rapaka, Athira Jacob, Carlo N De Cecco, Marly van Assen","doi":"10.1007/s10554-026-03832-4","DOIUrl":null,"url":null,"abstract":"<p><p>Left atrial (LA) volume is a powerful prognostic factor in cardiovascular disease with emerging AI-driven quantification from non-contrast coronary artery calcium (CAC) CT. The accuracy and agreement of such volume quantification with echocardiography, however, is not well studied. This study compares LA volumes captured from CAC CT and transthoracic two-dimensional echocardiography (2DE). This retrospective cohort included 220 patients undergoing both echocardiography and CAC CT within a 1-year period. CAC CT images were analyzed using a deep learning-based autoencoder model to derive chamber volumes. LA volume measurements were compared using Pearson correlation and Bland-Altman plots. Sub analysis was performed based on CT cardiac phase, body mass index, and sex with LA volume indexed to body-surface area (BSA). Mean LA volume differed significantly between 2DE and CAC CT with volumes of 32.2 ± 13.7 mL/m2 and 45.7 ± 15.9 mL/m2 (P < 0.001), respectively. CAC CT-derived LA volume correlated strongly with 2DE-measured LA volume (r = 0.82, ICC = 0.57, P < 0.001) and substantially with clinical severity (Cohen's κ = 0.70, P < 0.001). 2D-echo systematically underestimated LA volume with CAC-CT, with bias of 13.5 mL/m2 [95% CI, 12.3-14.7]. Agreement remained consistent for patients with (r = 0.83, ICC = 0.66, P < 0.001) and without (r = 0.77, ICC = 0.62, P < 0.001) heart failure. Inter-modality agreement for chamber volumes remained robust across sex, BMI, cardiac phase, and vendor sub-analyses. AI-derived LA volume from CAC CT demonstrated strong correlations with 2DE measurements and severity regardless of cardiac phase, BMI, and sex. Despite systematic differences in absolute volume compared to 2DE, CAC CT revealed relative LA remodeling, supporting the use of CAC CT as a modality for chamber quantification.</p>","PeriodicalId":94227,"journal":{"name":"The international journal of cardiovascular imaging","volume":" ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2026-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The international journal of cardiovascular imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10554-026-03832-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Left atrial (LA) volume is a powerful prognostic factor in cardiovascular disease with emerging AI-driven quantification from non-contrast coronary artery calcium (CAC) CT. The accuracy and agreement of such volume quantification with echocardiography, however, is not well studied. This study compares LA volumes captured from CAC CT and transthoracic two-dimensional echocardiography (2DE). This retrospective cohort included 220 patients undergoing both echocardiography and CAC CT within a 1-year period. CAC CT images were analyzed using a deep learning-based autoencoder model to derive chamber volumes. LA volume measurements were compared using Pearson correlation and Bland-Altman plots. Sub analysis was performed based on CT cardiac phase, body mass index, and sex with LA volume indexed to body-surface area (BSA). Mean LA volume differed significantly between 2DE and CAC CT with volumes of 32.2 ± 13.7 mL/m2 and 45.7 ± 15.9 mL/m2 (P < 0.001), respectively. CAC CT-derived LA volume correlated strongly with 2DE-measured LA volume (r = 0.82, ICC = 0.57, P < 0.001) and substantially with clinical severity (Cohen's κ = 0.70, P < 0.001). 2D-echo systematically underestimated LA volume with CAC-CT, with bias of 13.5 mL/m2 [95% CI, 12.3-14.7]. Agreement remained consistent for patients with (r = 0.83, ICC = 0.66, P < 0.001) and without (r = 0.77, ICC = 0.62, P < 0.001) heart failure. Inter-modality agreement for chamber volumes remained robust across sex, BMI, cardiac phase, and vendor sub-analyses. AI-derived LA volume from CAC CT demonstrated strong correlations with 2DE measurements and severity regardless of cardiac phase, BMI, and sex. Despite systematic differences in absolute volume compared to 2DE, CAC CT revealed relative LA remodeling, supporting the use of CAC CT as a modality for chamber quantification.

人工智能辅助下CAC CT左房容积量化:与超声心动图的比较。
左心房(LA)容积是心血管疾病的一个强有力的预后因素,新兴的人工智能驱动的冠状动脉钙化(CAC) CT量化。然而,这种超声心动图定量的准确性和一致性还没有得到很好的研究。本研究比较了CAC CT和经胸二维超声心动图(2DE)捕获的LA体积。该回顾性队列包括220例在1年内接受超声心动图和CAC CT检查的患者。使用基于深度学习的自动编码器模型分析CAC CT图像以获得腔室体积。使用Pearson相关性和Bland-Altman图比较LA容积测量值。亚组分析基于CT心脏期、体重指数和性别,LA体积与体表面积(BSA)相关。2DE和CAC CT的LA平均体积分别为32.2±13.7 mL/m2和45.7±15.9 mL/m2 (P
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书