Transportability of an artificial intelligence electrocardiography model for structural heart disease: external validation and recalibration of EchoNext-Mini in MIMIC-IV.

IF 4.4 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
European heart journal. Digital health Pub Date : 2026-09-19 eCollection Date: 2026-10-01 DOI:10.1093/ehjdh/ztag147
Emmanuel Otabor, Abdulraheem Hassan, Ayoyimika Okunlola, Justin Lam, Laith Alomari, Michael Hamilton
{"title":"Transportability of an artificial intelligence electrocardiography model for structural heart disease: external validation and recalibration of EchoNext-Mini in MIMIC-IV.","authors":"Emmanuel Otabor, Abdulraheem Hassan, Ayoyimika Okunlola, Justin Lam, Laith Alomari, Michael Hamilton","doi":"10.1093/ehjdh/ztag147","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Structural heart disease is often underdiagnosed, and echocardiography is limited by access and referral thresholds. Artificial intelligence electrocardiography (AI-ECG) may identify echocardiographically defined structural heart disease. EchoNext-Mini is a released AI-ECG model, accompanied by a benchmark dataset, that detects a composite structural heart disease outcome and component conditions from 12-lead electrocardiogram waveforms together with age, sex, and electrocardiographic measurements. We assessed its transportability and recalibration.</p><p><strong>Methods and results: </strong>We linked electrocardiograms from MIMIC-IV to subsequent transthoracic echocardiograms, including adults whose electrocardiogram preceded an eligible echocardiogram within one year, one per patient. Labels were mapped to structured echocardiographic fields using original thresholds where available, harmonized definitions otherwise. The released model was applied without retraining to this cohort and its benchmark test set, then assessed for discrimination, calibration, recalibration, subgroups, and label sensitivity. Among 45 878 patients, structural heart disease prevalence was 47.2%. Composite area under the receiver operating characteristic curve was 0.790 (95% confidence interval, 0.786 to 0.794), against 0.820 on the benchmark test set. Component values ranged from 0.679 for left ventricular wall thickness to 0.837 for right ventricular dysfunction. The composite was near-calibrated (slope, 0.93), whereas all component probabilities overestimated risk in both settings. A shift derived from the released training prevalences, requiring no local outcome data, largely corrected it.</p><p><strong>Conclusion: </strong>EchoNext-Mini transported to MIMIC-IV with composite discrimination within the published external-validation range. Component probabilities behaved as ranking scores rather than absolute risks, a property of the released model rather than the validation setting, and require adjustment before use as risk estimates.</p>","PeriodicalId":72965,"journal":{"name":"European heart journal. Digital health","volume":"7 8","pages":"ztag147"},"PeriodicalIF":4.4000,"publicationDate":"2026-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13617667/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European heart journal. Digital health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjdh/ztag147","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/10/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: Structural heart disease is often underdiagnosed, and echocardiography is limited by access and referral thresholds. Artificial intelligence electrocardiography (AI-ECG) may identify echocardiographically defined structural heart disease. EchoNext-Mini is a released AI-ECG model, accompanied by a benchmark dataset, that detects a composite structural heart disease outcome and component conditions from 12-lead electrocardiogram waveforms together with age, sex, and electrocardiographic measurements. We assessed its transportability and recalibration.

Methods and results: We linked electrocardiograms from MIMIC-IV to subsequent transthoracic echocardiograms, including adults whose electrocardiogram preceded an eligible echocardiogram within one year, one per patient. Labels were mapped to structured echocardiographic fields using original thresholds where available, harmonized definitions otherwise. The released model was applied without retraining to this cohort and its benchmark test set, then assessed for discrimination, calibration, recalibration, subgroups, and label sensitivity. Among 45 878 patients, structural heart disease prevalence was 47.2%. Composite area under the receiver operating characteristic curve was 0.790 (95% confidence interval, 0.786 to 0.794), against 0.820 on the benchmark test set. Component values ranged from 0.679 for left ventricular wall thickness to 0.837 for right ventricular dysfunction. The composite was near-calibrated (slope, 0.93), whereas all component probabilities overestimated risk in both settings. A shift derived from the released training prevalences, requiring no local outcome data, largely corrected it.

Conclusion: EchoNext-Mini transported to MIMIC-IV with composite discrimination within the published external-validation range. Component probabilities behaved as ranking scores rather than absolute risks, a property of the released model rather than the validation setting, and require adjustment before use as risk estimates.

结构性心脏病人工智能心电图模型的可移植性:MIMIC-IV中EchoNext-Mini的外部验证和重新校准
目的:结构性心脏病常被误诊,超声心动图受通道和转诊阈值的限制。人工智能心电图(AI-ECG)可以识别超声心动图定义的结构性心脏病。EchoNext-Mini是一款已发布的AI-ECG模型,配有基准数据集,可从12导联心电图波形中检测复合结构性心脏病结果和成分状况,以及年龄、性别和心电图测量值。我们评估了它的可运输性和重新校准。方法和结果:我们将MIMIC-IV的心电图与随后的经胸超声心动图联系起来,包括在一年内进行合格超声心动图之前进行心电图检查的成年人,每位患者一次。标签被映射到结构化超声心动图场使用原始阈值,否则协调定义。发布的模型未经再训练应用于该队列及其基准测试集,然后评估区分、校准、再校准、亚组和标签敏感性。45 878例患者中,结构性心脏病患病率为47.2%。受试者工作特征曲线下的复合面积为0.790(95%可信区间为0.786 ~ 0.794),而基准测试集的复合面积为0.820。分量值从左室壁厚0.679到右室功能障碍0.837不等。该组合是近校准的(斜率,0.93),而在两种情况下,所有成分概率都高估了风险。从公布的培训流行率得出的转变,不需要当地结果数据,在很大程度上纠正了它。结论:EchoNext-Mini转运到MIMIC-IV的复合鉴别在公布的外部验证范围内。组件概率表现为排名分数而不是绝对风险,是发布模型的属性而不是验证设置,并且需要在用作风险估计之前进行调整。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.00
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书