Intraoperative monitoring of malignant liver tumor microwave ablation using contrast-enhanced ultrasound: A preliminary study.

Ivor Dropco, Nina Käser, Ulrich Kaiser, Paul Kupke, Hans Jürgen Schlitt, Stefan M Brunner, Christina Hackl, Christian Stroszczynski, Ernst Michael Jung
{"title":"Intraoperative monitoring of malignant liver tumor microwave ablation using contrast-enhanced ultrasound: A preliminary study.","authors":"Ivor Dropco, Nina Käser, Ulrich Kaiser, Paul Kupke, Hans Jürgen Schlitt, Stefan M Brunner, Christina Hackl, Christian Stroszczynski, Ernst Michael Jung","doi":"10.1177/13860291261491824","DOIUrl":null,"url":null,"abstract":"<p><p>ObjectiveThis study aimed to evaluate intraoperative assessment and monitoring of liver tumor ablations using contrast-enhanced ultrasound (CEUS).MethodsTwenty patients (11 males [65%] and 9 females [45%]) with malignant lesions (cholangiocellular carcinoma (CCC), 1; hepatocellular carcinoma (HCC), 5; colorectal liver metastases (CRLM), 13; and one patient with alveolar echinococcosis) were examined intraoperatively with CEUS. Images were acquired in cine loops, covering the early arterial phase (0-15 s) up to the portal venous phase (1 min). Ablation was performed under real-time ultrasound guidance using microwave ablation (MWA). The generator output was adjusted up to 80 watts, up to 10 min. Post-ablation CEUS was conducted for immediate control.ResultsTwenty patients underwent ablation procedures. Ablation was carried out under ultrasound guidance with adjusted output settings between 40 and 80 watts and durations ranging from 2 to 5 min. Post-interventional CEUS confirmed complete devascularization in all planes. All patients underwent track ablation using 70 watts. At 6-month follow-up, no local recurrence was observed.ConclusionThe preliminary findings demonstrate the feasibility of intraoperative CEUS during microwave ablation of liver lesions. The technique proves to be a safe and effective intraoperative tool, owing to its ability to provide verification of complete tumor devascularization.</p>","PeriodicalId":93943,"journal":{"name":"Clinical hemorheology and microcirculation","volume":" ","pages":"13860291261491824"},"PeriodicalIF":0.0000,"publicationDate":"2026-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical hemorheology and microcirculation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/13860291261491824","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

ObjectiveThis study aimed to evaluate intraoperative assessment and monitoring of liver tumor ablations using contrast-enhanced ultrasound (CEUS).MethodsTwenty patients (11 males [65%] and 9 females [45%]) with malignant lesions (cholangiocellular carcinoma (CCC), 1; hepatocellular carcinoma (HCC), 5; colorectal liver metastases (CRLM), 13; and one patient with alveolar echinococcosis) were examined intraoperatively with CEUS. Images were acquired in cine loops, covering the early arterial phase (0-15 s) up to the portal venous phase (1 min). Ablation was performed under real-time ultrasound guidance using microwave ablation (MWA). The generator output was adjusted up to 80 watts, up to 10 min. Post-ablation CEUS was conducted for immediate control.ResultsTwenty patients underwent ablation procedures. Ablation was carried out under ultrasound guidance with adjusted output settings between 40 and 80 watts and durations ranging from 2 to 5 min. Post-interventional CEUS confirmed complete devascularization in all planes. All patients underwent track ablation using 70 watts. At 6-month follow-up, no local recurrence was observed.ConclusionThe preliminary findings demonstrate the feasibility of intraoperative CEUS during microwave ablation of liver lesions. The technique proves to be a safe and effective intraoperative tool, owing to its ability to provide verification of complete tumor devascularization.

肝恶性肿瘤微波消融术中超声造影监测的初步研究。
目的探讨超声造影(CEUS)在肝肿瘤消融术中评估和监测的价值。方法20例恶性病变(胆管细胞癌1例,男性11例(65%),女性9例(45%);肝细胞癌,5例;结直肠肝转移(CRLM), 13例;术中超声造影检查1例肺泡包虫病患者。图像在电影循环中获得,覆盖早期动脉期(0-15秒)到门静脉期(1分钟)。在实时超声引导下使用微波消融(MWA)进行消融。发电机输出调节到80瓦,持续10分钟。消融后进行超声造影以立即控制。结果20例患者行消融术。消融在超声引导下进行,调节输出设置在40至80瓦之间,持续时间为2至5分钟。介入后超声造影证实各平面血管完全断流。所有患者均行70瓦径道消融。随访6个月,未见局部复发。结论术中超声造影应用于肝脏微波消融术是可行的。该技术被证明是一种安全有效的术中工具,因为它能够提供肿瘤完全断流的验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书