{"title":"Emulating the influence of exoskeleton stiffness on primary afferent feedback in rat isolated muscle-tendon unit.","authors":"Amro A Alshareef, Paul Nardelli, Surabhi N Simha, Timothy C Cope, Lena H Ting, Gregory S Sawicki","doi":"10.1242/jeb.252345","DOIUrl":null,"url":null,"abstract":"<p><p>Exoskeletons assist and augment movement, but their effects on proprioceptive feedback remain poorly understood due to challenges in making direct measures of sensory signals in humans. Here, we leveraged a benchtop animal model to explore how mechanical context akin to an elastic exoskeleton operating on a human lower limb joint influences primary muscle spindle firing. In an anesthetized rat preparation, we applied controlled stretches to the medial gastrocnemius with engineered springs (0-0.5 N/mm) in parallel to the muscle-tendon unit (MTU) while modulating muscle activation to maintain overall system stiffness. Fascicle length was measured with sonomicrometry, force and MTU length with a servo motor, and spindle instantaneous firing rate (IFR) using dorsal root recordings. Trading off increases in exoskeleton stiffness with reductions in muscle activation decreased biological muscle force (3.1±0.6 N to 1.6±0.6 N, p<0.001) and stiffness (4.4±1.5 N/mm to 2.3±1.3 N/mm, p<0.01), and increased fascicle length (7.9±1.3 mm to 8.3±1.5 mm, p<0.005). We found significant correlations between spindle firing and each independent fascicle dynamics factor we investigated (p<0.005). Thus, parallel stiffness modified muscle fascicle dynamics but did not alter spindle firing, possibly due to internal trade-offs in the salient fascicle dynamics that drive spindle behavior. Leveraging in-situ experiments that enable monitoring of afferent feedback in complex mechanical contexts such as added parallel stiffness can provide a window into the effects of wearable devices on underlying sensory systems.</p>","PeriodicalId":15786,"journal":{"name":"Journal of Experimental Biology","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2026-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Experimental Biology","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1242/jeb.252345","RegionNum":2,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Exoskeletons assist and augment movement, but their effects on proprioceptive feedback remain poorly understood due to challenges in making direct measures of sensory signals in humans. Here, we leveraged a benchtop animal model to explore how mechanical context akin to an elastic exoskeleton operating on a human lower limb joint influences primary muscle spindle firing. In an anesthetized rat preparation, we applied controlled stretches to the medial gastrocnemius with engineered springs (0-0.5 N/mm) in parallel to the muscle-tendon unit (MTU) while modulating muscle activation to maintain overall system stiffness. Fascicle length was measured with sonomicrometry, force and MTU length with a servo motor, and spindle instantaneous firing rate (IFR) using dorsal root recordings. Trading off increases in exoskeleton stiffness with reductions in muscle activation decreased biological muscle force (3.1±0.6 N to 1.6±0.6 N, p<0.001) and stiffness (4.4±1.5 N/mm to 2.3±1.3 N/mm, p<0.01), and increased fascicle length (7.9±1.3 mm to 8.3±1.5 mm, p<0.005). We found significant correlations between spindle firing and each independent fascicle dynamics factor we investigated (p<0.005). Thus, parallel stiffness modified muscle fascicle dynamics but did not alter spindle firing, possibly due to internal trade-offs in the salient fascicle dynamics that drive spindle behavior. Leveraging in-situ experiments that enable monitoring of afferent feedback in complex mechanical contexts such as added parallel stiffness can provide a window into the effects of wearable devices on underlying sensory systems.
外骨骼辅助和增强运动,但它们对本体感觉反馈的影响仍然知之甚少,因为在直接测量人类的感觉信号方面存在挑战。在这里,我们利用台式动物模型来探索类似于弹性外骨骼在人类下肢关节上操作的机械环境如何影响初级肌肉纺锤放电。在麻醉大鼠的准备过程中,我们使用工程弹簧(0-0.5 N/mm)平行于肌肉-肌腱单元(MTU)对腓肠肌内侧进行控制拉伸,同时调节肌肉激活以保持整体系统刚度。用声测法测量束束长度,用伺服电机测量力和MTU长度,用背根记录纺锤体瞬时射速(IFR)。外骨骼硬度的增加与肌肉激活的减少之间的权衡降低了生物肌肉力(3.1±0.6 N至1.6±0.6 N, p
期刊介绍:
Journal of Experimental Biology is the leading primary research journal in comparative physiology and publishes papers on the form and function of living organisms at all levels of biological organisation, from the molecular and subcellular to the integrated whole animal.