Efficacy of Noninvasive Ventilatory Therapies Through Different Interfaces in the Postoperative Care of Cardiac Surgery Patients: A Randomized Controlled Trial.

IF 2.6 4区 医学 Q2 ANESTHESIOLOGY
Bruno Memória Rodrigues Okubo, José Glauco Lobo Filho, Heraldo Guedis Lobo Filho, Antônio Brazil Viana Júnior, Andréa da Nóbrega Cirino Nogueira
{"title":"Efficacy of Noninvasive Ventilatory Therapies Through Different Interfaces in the Postoperative Care of Cardiac Surgery Patients: A Randomized Controlled Trial.","authors":"Bruno Memória Rodrigues Okubo, José Glauco Lobo Filho, Heraldo Guedis Lobo Filho, Antônio Brazil Viana Júnior, Andréa da Nóbrega Cirino Nogueira","doi":"10.1053/j.jvca.2026.09.001","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To compare the clinical efficacy of 5 noninvasive ventilatory strategies-delivered via a conventional oronasal mask, a conventional full-face mask, the Wolf Mask full-face interface, the ELMO helmet (continuous positive airway pressure), and high-flow nasal cannula-against conventional physiotherapy without active ventilatory support in patients following elective cardiac surgery.</p><p><strong>Design: </strong>Prospective, randomized, controlled trial.</p><p><strong>Setting: </strong>High-complexity intensive care unit (ICU) of a tertiary care hospital from July 2023 to May 2026.</p><p><strong>Participants: </strong>In total, 172 patients undergoing elective coronary artery bypass grafting or valve surgery, randomized into 6 groups (G-FA, G-FULL, G-WOLF, G-ELMO, G-TAF, and G-CONTR).</p><p><strong>Interventions: </strong>Three daily 60-minute sessions of the assigned ventilatory modality integrated into standard physiotherapy care, from ICU admission to discharge.</p><p><strong>Measurements and main results: </strong>The primary outcomes were interface comfort and mobilization progression, with postoperative pulmonary complications as a secondary outcome. The Wolf Mask achieved the highest comfort score (9.41 ± 0.68 on a 0-10 visual analog scale) and required the lowest inspiratory pressure support (5.62 ± 2.08 cmH₂O) to reach the target tidal volume (6 mL/kg ideal body weight), suggesting superior mechanical efficiency. It was the only interface with no recorded cases of bibasal atelectasis and showed the lowest overall pulmonary complication rate. The conventional full-face mask yielded the second-best performance in comfort, arterial oxygenation, and pulmonary protection. High-flow nasal cannula proved safe but offered no advantage over full-face interfaces in pulmonary or functional outcomes. The ELMO helmet was hemodynamically safe and produced no hypercapnia but registered comfort scores among the lowest, statistically comparable to those of the conventional oronasal mask, along with the poorest oxygenation values. The control group had the highest complication rate, the lowest mobilization levels, and the smallest proportion of patients reaching mobilization level 3 at ICU discharge (18% v 73%-74% in the full-face groups). Interface comfort was identified as an independent positive predictor of mobilization progression by linear mixed-effects modeling (p = 0.004).</p><p><strong>Conclusions: </strong>In this trial, full-face interfaces, and the Wolf Mask in particular, were associated with the highest comfort and the lowest inspiratory pressure support, and interface comfort was an independent predictor of mobilization progression. The pulmonary and oxygenation findings were exploratory and hypothesis-generating. These results support the deliberate selection of well-tolerated full-face interfaces in postoperative cardiac surgery care and warrant confirmation in multicenter trials with longer follow-up.</p>","PeriodicalId":15176,"journal":{"name":"Journal of cardiothoracic and vascular anesthesia","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2026-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cardiothoracic and vascular anesthesia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1053/j.jvca.2026.09.001","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To compare the clinical efficacy of 5 noninvasive ventilatory strategies-delivered via a conventional oronasal mask, a conventional full-face mask, the Wolf Mask full-face interface, the ELMO helmet (continuous positive airway pressure), and high-flow nasal cannula-against conventional physiotherapy without active ventilatory support in patients following elective cardiac surgery.

Design: Prospective, randomized, controlled trial.

Setting: High-complexity intensive care unit (ICU) of a tertiary care hospital from July 2023 to May 2026.

Participants: In total, 172 patients undergoing elective coronary artery bypass grafting or valve surgery, randomized into 6 groups (G-FA, G-FULL, G-WOLF, G-ELMO, G-TAF, and G-CONTR).

Interventions: Three daily 60-minute sessions of the assigned ventilatory modality integrated into standard physiotherapy care, from ICU admission to discharge.

Measurements and main results: The primary outcomes were interface comfort and mobilization progression, with postoperative pulmonary complications as a secondary outcome. The Wolf Mask achieved the highest comfort score (9.41 ± 0.68 on a 0-10 visual analog scale) and required the lowest inspiratory pressure support (5.62 ± 2.08 cmH₂O) to reach the target tidal volume (6 mL/kg ideal body weight), suggesting superior mechanical efficiency. It was the only interface with no recorded cases of bibasal atelectasis and showed the lowest overall pulmonary complication rate. The conventional full-face mask yielded the second-best performance in comfort, arterial oxygenation, and pulmonary protection. High-flow nasal cannula proved safe but offered no advantage over full-face interfaces in pulmonary or functional outcomes. The ELMO helmet was hemodynamically safe and produced no hypercapnia but registered comfort scores among the lowest, statistically comparable to those of the conventional oronasal mask, along with the poorest oxygenation values. The control group had the highest complication rate, the lowest mobilization levels, and the smallest proportion of patients reaching mobilization level 3 at ICU discharge (18% v 73%-74% in the full-face groups). Interface comfort was identified as an independent positive predictor of mobilization progression by linear mixed-effects modeling (p = 0.004).

Conclusions: In this trial, full-face interfaces, and the Wolf Mask in particular, were associated with the highest comfort and the lowest inspiratory pressure support, and interface comfort was an independent predictor of mobilization progression. The pulmonary and oxygenation findings were exploratory and hypothesis-generating. These results support the deliberate selection of well-tolerated full-face interfaces in postoperative cardiac surgery care and warrant confirmation in multicenter trials with longer follow-up.

通过不同接口的无创通气治疗在心脏手术患者术后护理中的疗效:一项随机对照试验。
目的:比较5种无创通气策略(常规口鼻面罩、常规全面面罩、Wolf面罩全面接口、ELMO头盔(持续气道正压通气)和高流量鼻插管)对择期心脏手术后无主动通气支持的常规物理治疗的临床疗效。设计:前瞻性、随机、对照试验。环境:2023年7月至2026年5月在一家三级医院的高复杂性重症监护病房(ICU)。参与者:共172例接受择期冠状动脉旁路移植术或瓣膜手术的患者,随机分为6组(G-FA、G-FULL、G-WOLF、G-ELMO、G-TAF和G-CONTR)。干预措施:每日三次60分钟的指定通气方式,纳入标准物理治疗护理,从ICU入院到出院。测量和主要结果:主要结果是界面舒适和活动进展,术后肺部并发症为次要结果。在0-10级视觉模拟评分中,狼面具获得了最高的舒适度评分(9.41±0.68),并且需要最低的吸气压力支持(5.62±2.08 cmH₂O)才能达到目标潮气量(6 mL/kg理想体重),表明其具有优越的机械效率。这是唯一没有记录双基底不张病例的界面,显示了最低的总体肺部并发症发生率。传统的全脸面罩在舒适性、动脉氧合和肺保护方面的表现次之。高流量鼻插管被证明是安全的,但在肺或功能方面没有比全面插管更有利的结果。ELMO头盔是血流动力学安全的,不会产生高碳酸血症,但舒适性评分最低,与传统的口鼻面罩相当,氧合值也最差。对照组并发症发生率最高,活动水平最低,出院时达到3级活动水平的患者比例最小(18% vs正面组73%-74%)。通过线性混合效应模型,界面舒适度被确定为活动进展的独立阳性预测因子(p = 0.004)。结论:在本试验中,全面界面,特别是狼面具,与最高的舒适性和最低的吸气压力支持相关,界面舒适性是活动进展的独立预测因子。肺部和氧合的发现是探索性的,并产生了假设。这些结果支持在心脏手术术后护理中慎重选择耐受性良好的全面接口,并值得在多中心试验中进行更长的随访。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.80
自引率
17.90%
发文量
606
审稿时长
37 days
期刊介绍: The Journal of Cardiothoracic and Vascular Anesthesia is primarily aimed at anesthesiologists who deal with patients undergoing cardiac, thoracic or vascular surgical procedures. JCVA features a multidisciplinary approach, with contributions from cardiac, vascular and thoracic surgeons, cardiologists, and other related specialists. Emphasis is placed on rapid publication of clinically relevant material.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书