Maryam Afzali, Irvin Teh, Sam Coveney, Lars Mueller, Isaac Watson, May Lwin, Sarah Jones, Fabrizio Fasano, C John Evans, Filip Szczepankiewicz, Derek K Jones, Erica Dall'Armellina, Jürgen E Schneider
{"title":"Dual-phase systolic and diastolic cardiac diffusion tensor imaging using higher order motion compensation spin echo sequences at 300 mT/m gradient strength.","authors":"Maryam Afzali, Irvin Teh, Sam Coveney, Lars Mueller, Isaac Watson, May Lwin, Sarah Jones, Fabrizio Fasano, C John Evans, Filip Szczepankiewicz, Derek K Jones, Erica Dall'Armellina, Jürgen E Schneider","doi":"10.1016/j.jocmr.2026.102805","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cardiac diffusion tensor imaging (cDTI) provides unique insights into myocardial microstructure and its dynamic changes during the cardiac cycle. However, motion sensitivity remains a major obstacle for spin echo (SE)-based approaches, restricting most implementations to a relatively narrow low-motion window near peak systole.</p><p><strong>Purpose: </strong>To establish whether higher-order motion-compensated (up to 6th order) diffusion gradients beyond standard second order motion compensation (M<sub>2</sub>) on a magnetic resonance imaging (MRI) system with a maximum gradient strength of 300 mT/m improve SE-based cDTI techniques for both systolic and diastolic acquisitions.</p><p><strong>Methods: </strong>Ten healthy volunteers underwent free-breathing, cardiac-gated SE-cDTI acquisitions in systole and in diastole using diffusion gradients with up to second- (M<sub>2</sub>), fourth- (M<sub>4</sub>), and sixth-order (M<sub>6</sub>) motion compensation. Success rate (percentage of left ventricular voxels with (1.1 < MD < 1.9) × 10<sup>-3</sup>mm<sup>2</sup>∕s) and diffusion measures including mean diffusivity, fractional anisotropy, helix angle, and secondary eigenvector angle were quantified and compared between both cardiac phases.</p><p><strong>Results: </strong>Second-order motion compensation was sufficient for systolic cDTI, whereas fourth-order motion compensation was required for successful diastolic acquisitions in all participants. Mean diffusivity values in systole were (1.53 ± 0.06), (1.60 ± 0.07), and (1.62 ± 0.06) × 10<sup>-3</sup>mm<sup>2</sup>∕s for M<sub>2</sub>, M<sub>4</sub>, and M<sub>6</sub> respectively, and in diastole were (2.26 ± 0.67), (1.73 ± 0.19), and (1.71 ± 0.12) × 10<sup>-3</sup>mm<sup>2</sup>∕s. No significant differences in cDTI-derived parameters were observed between M<sub>4</sub> and M<sub>6</sub> for systolic and diastolic acquisitions.</p><p><strong>Conclusion: </strong>This study demonstrates the feasibility of dual-phase SE-based cDTI techniques enabled by 300 mT/m gradients. This method will allow reliable quantification of myocardial microstructural changes between systole and diastole and represents a step towards clinical translation of dynamic cDTI.</p>","PeriodicalId":15221,"journal":{"name":"Journal of Cardiovascular Magnetic Resonance","volume":" ","pages":"102805"},"PeriodicalIF":5.0000,"publicationDate":"2026-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Magnetic Resonance","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jocmr.2026.102805","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Cardiac diffusion tensor imaging (cDTI) provides unique insights into myocardial microstructure and its dynamic changes during the cardiac cycle. However, motion sensitivity remains a major obstacle for spin echo (SE)-based approaches, restricting most implementations to a relatively narrow low-motion window near peak systole.
Purpose: To establish whether higher-order motion-compensated (up to 6th order) diffusion gradients beyond standard second order motion compensation (M2) on a magnetic resonance imaging (MRI) system with a maximum gradient strength of 300 mT/m improve SE-based cDTI techniques for both systolic and diastolic acquisitions.
Methods: Ten healthy volunteers underwent free-breathing, cardiac-gated SE-cDTI acquisitions in systole and in diastole using diffusion gradients with up to second- (M2), fourth- (M4), and sixth-order (M6) motion compensation. Success rate (percentage of left ventricular voxels with (1.1 < MD < 1.9) × 10-3mm2∕s) and diffusion measures including mean diffusivity, fractional anisotropy, helix angle, and secondary eigenvector angle were quantified and compared between both cardiac phases.
Results: Second-order motion compensation was sufficient for systolic cDTI, whereas fourth-order motion compensation was required for successful diastolic acquisitions in all participants. Mean diffusivity values in systole were (1.53 ± 0.06), (1.60 ± 0.07), and (1.62 ± 0.06) × 10-3mm2∕s for M2, M4, and M6 respectively, and in diastole were (2.26 ± 0.67), (1.73 ± 0.19), and (1.71 ± 0.12) × 10-3mm2∕s. No significant differences in cDTI-derived parameters were observed between M4 and M6 for systolic and diastolic acquisitions.
Conclusion: This study demonstrates the feasibility of dual-phase SE-based cDTI techniques enabled by 300 mT/m gradients. This method will allow reliable quantification of myocardial microstructural changes between systole and diastole and represents a step towards clinical translation of dynamic cDTI.
期刊介绍:
Journal of Cardiovascular Magnetic Resonance (JCMR) publishes high-quality articles on all aspects of basic, translational and clinical research on the design, development, manufacture, and evaluation of cardiovascular magnetic resonance (CMR) methods applied to the cardiovascular system. Topical areas include, but are not limited to:
New applications of magnetic resonance to improve the diagnostic strategies, risk stratification, characterization and management of diseases affecting the cardiovascular system.
New methods to enhance or accelerate image acquisition and data analysis.
Results of multicenter, or larger single-center studies that provide insight into the utility of CMR.
Basic biological perceptions derived by CMR methods.