A structured pre-procedural risk mitigation strategy for ultra-high-risk TAVR in a nonagenarian with extreme aortic valve calcification: a case report using a balloon-expandable valve and proactive ECMO backup.
Lang Hong, Zhaohui Liu, Xuehong Zhang, Chang Yao, Siping Peng
{"title":"A structured pre-procedural risk mitigation strategy for ultra-high-risk TAVR in a nonagenarian with extreme aortic valve calcification: a case report using a balloon-expandable valve and proactive ECMO backup.","authors":"Lang Hong, Zhaohui Liu, Xuehong Zhang, Chang Yao, Siping Peng","doi":"10.1186/s13019-026-04615-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Transcatheter aortic valve replacement (TAVR) in nonagenarians with extensive aortic valve calcification is associated with a substantial risk of intraprocedural circulatory collapse.</p><p><strong>Case presentation: </strong>This case report describes a structured pre-procedural risk mitigation strategy integrating a balloon-expandable valve system and a pre-emptive, \"wet-prepared\" extracorporeal membrane oxygenation (ECMO) backup. A 97-year-old man with severe symptomatic aortic stenosis (peak velocity = 4.76 m/s; aortic valve calcium volume = 1178 mm³) underwent transfemoral TAVR using a structured approach incorporating precision imaging, careful device selection using a domestic Chinese balloon-expandable valve system (Prizvalve<sup>®</sup> TAV23), proactive ECMO preparedness, and multidisciplinary team coordination. Immediately after valve deployment, the patient developed circulatory collapse (blood pressure = 40/20 mmHg). A predefined emergency protocol was promptly activated. Following chest compressions, vasopressor administration, and pacing optimization, spontaneous circulation was restored within minutes. Angiography confirmed stable valve positioning with satisfactory expansion. At 3-month follow-up, echocardiography demonstrated absence of paravalvular leakage and preserved left ventricular systolic function.</p><p><strong>Conclusions: </strong>This case demonstrates the feasibility of a structured, pre-procedural risk mitigation strategy for TAVR in an exceptionally high-risk patient. The approach enabled the management of intraprocedural circulatory collapse. In this setting, the balloon-expandable valve platform demonstrated procedural characteristics that were well suited for this complex anatomy.</p>","PeriodicalId":15201,"journal":{"name":"Journal of Cardiothoracic Surgery","volume":"21 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13617893/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiothoracic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13019-026-04615-7","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Transcatheter aortic valve replacement (TAVR) in nonagenarians with extensive aortic valve calcification is associated with a substantial risk of intraprocedural circulatory collapse.
Case presentation: This case report describes a structured pre-procedural risk mitigation strategy integrating a balloon-expandable valve system and a pre-emptive, "wet-prepared" extracorporeal membrane oxygenation (ECMO) backup. A 97-year-old man with severe symptomatic aortic stenosis (peak velocity = 4.76 m/s; aortic valve calcium volume = 1178 mm³) underwent transfemoral TAVR using a structured approach incorporating precision imaging, careful device selection using a domestic Chinese balloon-expandable valve system (Prizvalve® TAV23), proactive ECMO preparedness, and multidisciplinary team coordination. Immediately after valve deployment, the patient developed circulatory collapse (blood pressure = 40/20 mmHg). A predefined emergency protocol was promptly activated. Following chest compressions, vasopressor administration, and pacing optimization, spontaneous circulation was restored within minutes. Angiography confirmed stable valve positioning with satisfactory expansion. At 3-month follow-up, echocardiography demonstrated absence of paravalvular leakage and preserved left ventricular systolic function.
Conclusions: This case demonstrates the feasibility of a structured, pre-procedural risk mitigation strategy for TAVR in an exceptionally high-risk patient. The approach enabled the management of intraprocedural circulatory collapse. In this setting, the balloon-expandable valve platform demonstrated procedural characteristics that were well suited for this complex anatomy.
期刊介绍:
Journal of Cardiothoracic Surgery is an open access journal that encompasses all aspects of research in the field of Cardiology, and Cardiothoracic and Vascular Surgery. The journal publishes original scientific research documenting clinical and experimental advances in cardiac, vascular and thoracic surgery, and related fields.
Topics of interest include surgical techniques, survival rates, surgical complications and their outcomes; along with basic sciences, pediatric conditions, transplantations and clinical trials.
Journal of Cardiothoracic Surgery is of interest to cardiothoracic and vascular surgeons, cardiothoracic anaesthesiologists, cardiologists, chest physicians, and allied health professionals.