High- versus low-volume static stretching and eccentric exercise: a randomized controlled trial in older adults with hamstring tightness and possible sarcopenia.

IF 2.9 3区 医学 Q2 PHYSIOLOGY
Nongnuch Luangpon, Wirasinee Srijunto, Juntip Namsawang, Sirawee Chaovalit, Audrius Snieckus, Sarawut Lapmanee, Pornpimol Muanjai
{"title":"High- versus low-volume static stretching and eccentric exercise: a randomized controlled trial in older adults with hamstring tightness and possible sarcopenia.","authors":"Nongnuch Luangpon, Wirasinee Srijunto, Juntip Namsawang, Sirawee Chaovalit, Audrius Snieckus, Sarawut Lapmanee, Pornpimol Muanjai","doi":"10.1007/s00421-026-06446-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study examined the effects of home-based high-volume static stretching on range of motion (ROM), musculotendinous unit (MTU) stiffness, muscle morphology, strength, balance, and physical function in older adults with hamstring tightness and possible sarcopenia.</p><p><strong>Methods: </strong>Sixty-eight community-dwelling older adults (67.2 ± 4.5 years) were randomly assigned to high-volume static stretching (30 min/day), low-volume static stretching (3 min/day, 3 days/week), eccentric exercise (ECC), or non-intervention control (CON) for 6 weeks. Assessments conducted at baseline, post-intervention, and 3-month follow-up included muscle thickness (MT), ROM, MTU stiffness, isometric knee flexor strength, cross-education effects on contralateral strength, Y-Balance performance, and function outcomes.</p><p><strong>Results: </strong>Significant group × time interaction effects were observed for ROM and isometric strength (p < 0.05). ROM increased after both stretching interventions (12.4° high-volume; 10.3° low-volume; d = 1.27-1.48), with no statistically detectable between-group difference. Isometric knee flexor strength improved after ECC (≈ 7.0 Nm; d = 1.53), with no contralateral strength transfer. No consistent intervention-related improvements were observed in MTU stiffness, muscle thickness, Y-Balance, or physical function. At the 3-month follow-up, knee flexor strength differed from baseline in the ECC group, although this was an uncontrolled follow-up observation.</p><p><strong>Conclusions: </strong>No statistically detectable difference in ROM was identified between high- and low-volume stretching. Exploratory analyses indicated that ECC improved strength more than control, whereas stretching-related changes remained below the minimal detectable change. . Low-volume stretching required substantially less weekly exercise time than high-volume stretching; however, equivalence was not established. Stretching and eccentric exercise may therefore produce distinct flexibility and strength adaptations in older adults.</p><p><strong>Clinical registration: </strong>The study protocol has been registered with the Thai Clinical Trials Registry (TCTR20251222012).</p>","PeriodicalId":12005,"journal":{"name":"European Journal of Applied Physiology","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2026-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Applied Physiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00421-026-06446-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study examined the effects of home-based high-volume static stretching on range of motion (ROM), musculotendinous unit (MTU) stiffness, muscle morphology, strength, balance, and physical function in older adults with hamstring tightness and possible sarcopenia.

Methods: Sixty-eight community-dwelling older adults (67.2 ± 4.5 years) were randomly assigned to high-volume static stretching (30 min/day), low-volume static stretching (3 min/day, 3 days/week), eccentric exercise (ECC), or non-intervention control (CON) for 6 weeks. Assessments conducted at baseline, post-intervention, and 3-month follow-up included muscle thickness (MT), ROM, MTU stiffness, isometric knee flexor strength, cross-education effects on contralateral strength, Y-Balance performance, and function outcomes.

Results: Significant group × time interaction effects were observed for ROM and isometric strength (p < 0.05). ROM increased after both stretching interventions (12.4° high-volume; 10.3° low-volume; d = 1.27-1.48), with no statistically detectable between-group difference. Isometric knee flexor strength improved after ECC (≈ 7.0 Nm; d = 1.53), with no contralateral strength transfer. No consistent intervention-related improvements were observed in MTU stiffness, muscle thickness, Y-Balance, or physical function. At the 3-month follow-up, knee flexor strength differed from baseline in the ECC group, although this was an uncontrolled follow-up observation.

Conclusions: No statistically detectable difference in ROM was identified between high- and low-volume stretching. Exploratory analyses indicated that ECC improved strength more than control, whereas stretching-related changes remained below the minimal detectable change. . Low-volume stretching required substantially less weekly exercise time than high-volume stretching; however, equivalence was not established. Stretching and eccentric exercise may therefore produce distinct flexibility and strength adaptations in older adults.

Clinical registration: The study protocol has been registered with the Thai Clinical Trials Registry (TCTR20251222012).

高容量与低容量的静态拉伸和偏心运动:一项针对腘绳肌紧绷和可能的肌肉减少症的老年人的随机对照试验。
目的:本研究探讨了家庭大容量静态拉伸对老年腘绳肌紧绷和可能的肌少症患者的活动范围(ROM)、肌腱单位(MTU)僵硬度、肌肉形态、力量、平衡和身体功能的影响。方法:68名居住在社区的老年人(67.2±4.5岁)随机分为大容量静态拉伸(30分钟/天)、小容量静态拉伸(3分钟/天,3天/周)、离心运动(ECC)和非干预对照组(CON),为期6周。在基线、干预后和3个月随访时进行的评估包括肌肉厚度(MT)、ROM、MTU刚度、膝关节屈肌等距强度、交叉教育对对侧力量的影响、Y-Balance性能和功能结果。结果:ROM与等长强度组×时间交互作用显著(p < 0.05)。两种拉伸干预后ROM均增加(12.4°高容积;10.3°低容积;d = 1.27-1.48),组间差异无统计学意义。ECC后等距膝关节屈肌强度提高(≈7.0 Nm; d = 1.53),无对侧力量转移。在MTU僵硬度、肌肉厚度、Y-Balance或身体功能方面没有观察到持续的干预相关改善。在3个月的随访中,尽管这是一个不受控制的随访观察,但ECC组的膝关节屈肌力量与基线不同。结论:在高容量和低容量拉伸之间,ROM没有统计学上可检测的差异。探索性分析表明,ECC比对照组更能提高强度,而与拉伸相关的变化仍低于最小可检测变化。与大容量拉伸相比,小容量拉伸每周所需的锻炼时间要少得多;然而,等效性并没有确立。因此,拉伸和偏心运动可能会对老年人产生明显的柔韧性和力量适应性。临床注册:该研究方案已在泰国临床试验注册中心注册(TCTR20251222012)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.00
自引率
6.70%
发文量
227
审稿时长
3 months
期刊介绍: The European Journal of Applied Physiology (EJAP) aims to promote mechanistic advances in human integrative and translational physiology. Physiology is viewed broadly, having overlapping context with related disciplines such as biomechanics, biochemistry, endocrinology, ergonomics, immunology, motor control, and nutrition. EJAP welcomes studies dealing with physical exercise, training and performance. Studies addressing physiological mechanisms are preferred over descriptive studies. Papers dealing with animal models or pathophysiological conditions are not excluded from consideration, but must be clearly relevant to human physiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书