Exercise modality influences oxygen pulse flattening during incremental cardiopulmonary exercise testing in healthy adults.

IF 2.9 3区 医学 Q2 PHYSIOLOGY
Gur Mainzer, Faris Khourey, Merav Zucker-Toledano, Ronen Bar-Yoseph, Einat Kodesh
{"title":"Exercise modality influences oxygen pulse flattening during incremental cardiopulmonary exercise testing in healthy adults.","authors":"Gur Mainzer, Faris Khourey, Merav Zucker-Toledano, Ronen Bar-Yoseph, Einat Kodesh","doi":"10.1007/s00421-026-06437-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare oxygen pulse (O₂P) responses during cardiopulmonary exercise testing (CPET) in healthy adults using two ergometers, Treadmill and Cycle ergometer, and to determine the prevalence of O₂P flattening and the modality-specific characteristics of O₂P curve dynamics.</p><p><strong>Methods: </strong>Thirty-four healthy adults (29.4 ± 6.9 years; 35% female) completed two maximal CPETs on both Cycle and Treadmill, in a random order within three weeks. O₂P flattening, defined as the absence of a further increase in O₂P despite increasing workload, was assessed visually and confirmed quantitatively.</p><p><strong>Results: </strong>Twelve participants (35%) demonstrated O₂P flattening or decline, nine (27%) exclusively during Treadmill testing. A significant group × modality interaction was observed for peak O₂P (p < 0.05), with lower values in participants with flattening than in those showing a continuous rise. (Cycle: 9.9 ± 3.2 vs. 13.6 ± 2.7 ml/min/beat; Treadmill: 11.8 ± 3.7 vs. 16.6 ± 3.7 ml/min/beat). In addition, an O<sub>2</sub>P of ≤ 12.8 ml/beat on the Cycle increased the likelihood of flattening during maximal Treadmill exercise by 7.5 times (OR 7.5, p = 0.03).</p><p><strong>Conclusion: </strong>O₂P flattening was more frequently observed during treadmill exercise, indicating that O₂P trajectories are exercise modality dependent. In individuals with low peak O₂P during cycle ergometry, additional assessment using treadmill CPET may offer complementary information.</p>","PeriodicalId":12005,"journal":{"name":"European Journal of Applied Physiology","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2026-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Applied Physiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00421-026-06437-w","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare oxygen pulse (O₂P) responses during cardiopulmonary exercise testing (CPET) in healthy adults using two ergometers, Treadmill and Cycle ergometer, and to determine the prevalence of O₂P flattening and the modality-specific characteristics of O₂P curve dynamics.

Methods: Thirty-four healthy adults (29.4 ± 6.9 years; 35% female) completed two maximal CPETs on both Cycle and Treadmill, in a random order within three weeks. O₂P flattening, defined as the absence of a further increase in O₂P despite increasing workload, was assessed visually and confirmed quantitatively.

Results: Twelve participants (35%) demonstrated O₂P flattening or decline, nine (27%) exclusively during Treadmill testing. A significant group × modality interaction was observed for peak O₂P (p < 0.05), with lower values in participants with flattening than in those showing a continuous rise. (Cycle: 9.9 ± 3.2 vs. 13.6 ± 2.7 ml/min/beat; Treadmill: 11.8 ± 3.7 vs. 16.6 ± 3.7 ml/min/beat). In addition, an O2P of ≤ 12.8 ml/beat on the Cycle increased the likelihood of flattening during maximal Treadmill exercise by 7.5 times (OR 7.5, p = 0.03).

Conclusion: O₂P flattening was more frequently observed during treadmill exercise, indicating that O₂P trajectories are exercise modality dependent. In individuals with low peak O₂P during cycle ergometry, additional assessment using treadmill CPET may offer complementary information.

运动方式影响健康成人增量心肺运动试验期间氧脉冲变平。
目的:比较健康成人使用两种测力仪(跑步机和循环测力仪)进行心肺运动试验(CPET)时的氧脉冲(O₂P)反应,并确定O₂P变平的患病率和O₂P曲线动力学的模式特异性特征。方法:34名健康成人(29.4±6.9岁,女性35%)在三周内随机完成两次最大cpet,分别在自行车和跑步机上进行。O₂P扁平化,定义为尽管工作量增加,但O₂P没有进一步增加,通过视觉评估和定量确认。结果:12名参与者(35%)表现出O₂P平坦或下降,9名参与者(27%)完全在跑步机测试中表现出来。观察到显著的组与模态相互作用,峰值O₂P (P 2P≤12.8 ml/次)使最大跑步机运动期间扁平化的可能性增加7.5倍(OR 7.5, P = 0.03)。结论:在跑步机上运动时更容易观察到O₂P变平,这表明O₂P轨迹与运动方式有关。对于在周期测量中O₂P峰值较低的个体,使用跑步机CPET进行额外评估可以提供补充信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.00
自引率
6.70%
发文量
227
审稿时长
3 months
期刊介绍: The European Journal of Applied Physiology (EJAP) aims to promote mechanistic advances in human integrative and translational physiology. Physiology is viewed broadly, having overlapping context with related disciplines such as biomechanics, biochemistry, endocrinology, ergonomics, immunology, motor control, and nutrition. EJAP welcomes studies dealing with physical exercise, training and performance. Studies addressing physiological mechanisms are preferred over descriptive studies. Papers dealing with animal models or pathophysiological conditions are not excluded from consideration, but must be clearly relevant to human physiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书