Deep Learning-Based Assessment of Sleepiness from Fingertip Pulse Wave Analysis During Objective Daytime Testing.

IF 5.2 2区 医学 Q3 ENGINEERING, BIOMEDICAL
Matias Rusanen, Samu Kainulainen, Sami Myllymaa, Timo Leppänen, Renaud Tamisier, Sébastien Baillieul, Sébastien Bailly, Jean-Louis Pepin
{"title":"Deep Learning-Based Assessment of Sleepiness from Fingertip Pulse Wave Analysis During Objective Daytime Testing.","authors":"Matias Rusanen, Samu Kainulainen, Sami Myllymaa, Timo Leppänen, Renaud Tamisier, Sébastien Baillieul, Sébastien Bailly, Jean-Louis Pepin","doi":"10.1007/s10439-026-04393-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Objective evaluation of daytime sleepiness is a key factor in the management of sleep disorders. However, objective testing is limited due to the labor-intensive nature of standard methods; the Multiple Sleep Latency Test (MSLT) and the Maintenance of Wakefulness Test (MWT). Deep learning analysis of a simple fingertip pulse wave (photoplethysmography, PPG) recording could be a viable option for the routine assessment of sleepiness in patients with suspected sleep disorders.</p><p><strong>Methods: </strong>A deep learning-based sleep staging model was tested in MSLT (n = 143) and MWT (n = 127) datasets. The primary aim was to analyze the classification of subjects as sleepy versus non-sleepy using PPG-based sleep analysis. As an intermediate technical evaluation, we assessed PPG-based sleep-wake classification and mean sleep latency (MSL).</p><p><strong>Results: </strong>Classification of sleepiness status based on automatic MSL detection from PPG showed promising results in both MSLT (accuracy: 80%, sensitivity: 65%, specificity: 84%) and MWT (accuracy: 83%, sensitivity: 62%, specificity: 86%). Sleep probability curves estimated from the fingertip pulse wave differed significantly between sleepy and non-sleepy groups, both in MSLT (p = 0.0002) and in MWT (p = 0.0012) datasets. In MSLT, the model detected sleep with moderate agreement and balanced performance (accuracy 81%, precision 0.71, recall 0.80). In MWT, overall accuracy (88%) was strongly influenced by class imbalance (98% wakefulness), and direct second-by-second sleep detection showed limited precision (precision 0.10, recall 0.72). Automated MSL estimates showed correlation with manual scoring in both MSLT and MWT; however, larger errors and outliers were observed in MWT.</p><p><strong>Conclusion: </strong>Fingertip pulse wave analysis combined with deep learning shows feasibility for automated assessment of daytime sleepiness, particularly in MSLT. However, direct zero-shot application of a model trained on overnight PSG to MWT is limited by low sleep precision requiring methodological adaptation and daytime-specific optimization.</p>","PeriodicalId":7986,"journal":{"name":"Annals of Biomedical Engineering","volume":" ","pages":""},"PeriodicalIF":5.2000,"publicationDate":"2026-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10439-026-04393-2","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Objective evaluation of daytime sleepiness is a key factor in the management of sleep disorders. However, objective testing is limited due to the labor-intensive nature of standard methods; the Multiple Sleep Latency Test (MSLT) and the Maintenance of Wakefulness Test (MWT). Deep learning analysis of a simple fingertip pulse wave (photoplethysmography, PPG) recording could be a viable option for the routine assessment of sleepiness in patients with suspected sleep disorders.

Methods: A deep learning-based sleep staging model was tested in MSLT (n = 143) and MWT (n = 127) datasets. The primary aim was to analyze the classification of subjects as sleepy versus non-sleepy using PPG-based sleep analysis. As an intermediate technical evaluation, we assessed PPG-based sleep-wake classification and mean sleep latency (MSL).

Results: Classification of sleepiness status based on automatic MSL detection from PPG showed promising results in both MSLT (accuracy: 80%, sensitivity: 65%, specificity: 84%) and MWT (accuracy: 83%, sensitivity: 62%, specificity: 86%). Sleep probability curves estimated from the fingertip pulse wave differed significantly between sleepy and non-sleepy groups, both in MSLT (p = 0.0002) and in MWT (p = 0.0012) datasets. In MSLT, the model detected sleep with moderate agreement and balanced performance (accuracy 81%, precision 0.71, recall 0.80). In MWT, overall accuracy (88%) was strongly influenced by class imbalance (98% wakefulness), and direct second-by-second sleep detection showed limited precision (precision 0.10, recall 0.72). Automated MSL estimates showed correlation with manual scoring in both MSLT and MWT; however, larger errors and outliers were observed in MWT.

Conclusion: Fingertip pulse wave analysis combined with deep learning shows feasibility for automated assessment of daytime sleepiness, particularly in MSLT. However, direct zero-shot application of a model trained on overnight PSG to MWT is limited by low sleep precision requiring methodological adaptation and daytime-specific optimization.

基于深度学习的日间客观测试中指尖脉搏波分析的困倦评估。
目的:客观评价日间嗜睡是治疗睡眠障碍的关键因素。然而,由于标准方法的劳动强度,客观检测受到限制;多重睡眠潜伏期试验(MSLT)和清醒维持试验(MWT)。对简单的指尖脉搏波(photoplethysmography, PPG)记录进行深度学习分析,可能是对疑似睡眠障碍患者的嗜睡进行常规评估的可行选择。方法:在MSLT (n = 143)和MWT (n = 127)数据集上测试基于深度学习的睡眠分期模型。主要目的是使用基于ppg的睡眠分析来分析受试者的困倦和不困倦分类。作为中间技术评价,我们评估了基于ppg的睡眠-觉醒分类和平均睡眠潜伏期(MSL)。结果:基于PPG自动MSL检测的嗜睡状态分类在MSLT(准确性:80%,灵敏度:65%,特异性:84%)和MWT(准确性:83%,灵敏度:62%,特异性:86%)中都显示出良好的结果。在MSLT (p = 0.0002)和MWT (p = 0.0012)数据集中,从指尖脉搏波估计的睡眠概率曲线在困倦组和非困倦组之间存在显著差异。在MSLT中,模型检测睡眠具有中等一致性和平衡性能(准确率81%,精度0.71,召回率0.80)。在MWT中,总体准确率(88%)受到类别不平衡(98%清醒)的强烈影响,直接逐秒睡眠检测的精度有限(精度0.10,召回率0.72)。在MSLT和MWT中,自动MSL估计与人工评分均有相关性;然而,在MWT中观察到较大的误差和异常值。结论:指尖脉搏波分析结合深度学习显示了日间嗜睡自动评估的可行性,特别是在MSLT中。然而,将夜间PSG训练的模型直接零射击应用到MWT受到睡眠精度低的限制,需要方法上的适应和白天特定的优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of Biomedical Engineering
Annals of Biomedical Engineering 工程技术-工程:生物医学
CiteScore
7.50
自引率
15.80%
发文量
212
审稿时长
3 months
期刊介绍: Annals of Biomedical Engineering is an official journal of the Biomedical Engineering Society, publishing original articles in the major fields of bioengineering and biomedical engineering. The Annals is an interdisciplinary and international journal with the aim to highlight integrated approaches to the solutions of biological and biomedical problems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书