U. Konopada, V. Egger, L. Dankl, M. Nogler, R. Arora, E. Zanetti, C. Bignardi, D. Putzer
{"title":"An analysis of different reconstruction techniques for the radius: a finite element analysis","authors":"U. Konopada, V. Egger, L. Dankl, M. Nogler, R. Arora, E. Zanetti, C. Bignardi, D. Putzer","doi":"10.1007/s10237-026-02116-z","DOIUrl":null,"url":null,"abstract":"<div><p>Pathological fractures due to metastatic bone disease frequently require palliative stabilization. While polymethylmethacrylate (PMMA) provides immediate mechanical stabilization, its limited bending and multiaxial properties raise concerns. Reinforcement strategies such as plate fixation, intramedullary nails, and metallic augmentation have been proposed, yet their mechanical behavior under physiological loading remains insufficiently characterized. This study aims to evaluate the mechanical performance of three reconstruction strategies for a proximal radial defect: PMMA alone, PMMA combined with titanium plate-and-screw construct, and PMMA reinforced with a steel K-wire. A patient-specific workflow integrated musculoskeletal multibody model and finite element analysis. Muscle forces and elbow joint reaction forces were calculated for a static 90° shoulder flexion under two loading conditions: no external load and 2 kg mass applied at the center of mass of the hand. These forces were applied in finite element analysis in reconstructed forearm, and peak von Mises stress and displacements were evaluated. In loading scenario, elbow joint reaction force reached 314.4 N, and maximum muscle force was 120.8 N. In the PMMA-only construct, peak stress increased from 4.0 MPa (no load) to 12.0 MPa (with load). Plate fixation increased peak stress to 14.9 MPa in the loading case. K-wire reinforcement resulted in lowest PMMA peak stress (23% less with respect to PMMA-only and 38% less compared to titanium plate) but produced more pronounced displacement (29%) compared to plate fixation strategy. These findings suggest complementary mechanical benefits: K-wire reinforcement most effectively reduced peak cement stress, whereas plate fixation provided superior global stiffness.</p></div>","PeriodicalId":489,"journal":{"name":"Biomechanics and Modeling in Mechanobiology","volume":"25 5","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2026-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13619793/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomechanics and Modeling in Mechanobiology","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10237-026-02116-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
Pathological fractures due to metastatic bone disease frequently require palliative stabilization. While polymethylmethacrylate (PMMA) provides immediate mechanical stabilization, its limited bending and multiaxial properties raise concerns. Reinforcement strategies such as plate fixation, intramedullary nails, and metallic augmentation have been proposed, yet their mechanical behavior under physiological loading remains insufficiently characterized. This study aims to evaluate the mechanical performance of three reconstruction strategies for a proximal radial defect: PMMA alone, PMMA combined with titanium plate-and-screw construct, and PMMA reinforced with a steel K-wire. A patient-specific workflow integrated musculoskeletal multibody model and finite element analysis. Muscle forces and elbow joint reaction forces were calculated for a static 90° shoulder flexion under two loading conditions: no external load and 2 kg mass applied at the center of mass of the hand. These forces were applied in finite element analysis in reconstructed forearm, and peak von Mises stress and displacements were evaluated. In loading scenario, elbow joint reaction force reached 314.4 N, and maximum muscle force was 120.8 N. In the PMMA-only construct, peak stress increased from 4.0 MPa (no load) to 12.0 MPa (with load). Plate fixation increased peak stress to 14.9 MPa in the loading case. K-wire reinforcement resulted in lowest PMMA peak stress (23% less with respect to PMMA-only and 38% less compared to titanium plate) but produced more pronounced displacement (29%) compared to plate fixation strategy. These findings suggest complementary mechanical benefits: K-wire reinforcement most effectively reduced peak cement stress, whereas plate fixation provided superior global stiffness.
期刊介绍:
Mechanics regulates biological processes at the molecular, cellular, tissue, organ, and organism levels. A goal of this journal is to promote basic and applied research that integrates the expanding knowledge-bases in the allied fields of biomechanics and mechanobiology. Approaches may be experimental, theoretical, or computational; they may address phenomena at the nano, micro, or macrolevels. Of particular interest are investigations that
(1) quantify the mechanical environment in which cells and matrix function in health, disease, or injury,
(2) identify and quantify mechanosensitive responses and their mechanisms,
(3) detail inter-relations between mechanics and biological processes such as growth, remodeling, adaptation, and repair, and
(4) report discoveries that advance therapeutic and diagnostic procedures.
Especially encouraged are analytical and computational models based on solid mechanics, fluid mechanics, or thermomechanics, and their interactions; also encouraged are reports of new experimental methods that expand measurement capabilities and new mathematical methods that facilitate analysis.