Selina Hanselmann, Kirsten Grossmann, Ornella Céline Weideli, Vincent Sebastian Braunack-Mayer, Kenneth Vogt, Laura Velez Colorado, Martina Rothenbühler, Oliver Ullrich, Harald Renz, David Conen, Lorenz Risch, Martin Risch
{"title":"Association of Foehn winds with physiological parameters in a cohort of middle-aged adults","authors":"Selina Hanselmann, Kirsten Grossmann, Ornella Céline Weideli, Vincent Sebastian Braunack-Mayer, Kenneth Vogt, Laura Velez Colorado, Martina Rothenbühler, Oliver Ullrich, Harald Renz, David Conen, Lorenz Risch, Martin Risch","doi":"10.1007/s00484-026-03327-w","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Foehn winds, warm and dry downslope winds common in alpine regions, have long been suspected to affect human health, but objective evidence remains limited. Wearable devices now allow physiological responses to such conditions to be captured. This study investigates the association between Foehn winds and changes in physiological parameters.</p><h3>Methods</h3><p>Healthy adults in Liechtenstein wore a medical sensory wearable device during sleep over an 11-month period. Nightly physiological parameters were related to Foehn exposure in linear mixed-effects models.</p><h3>Results</h3><p>714 participants (59.7% women; mean age 44.0 years) were included. Foehn was associated with changes in heart rate (HR) (+ 0.25 bpm; 95% CI: 0.17, 0.33), perfusion index (PI) (+ 0.78%; 95% CI: 0.22, 1.33), and heart rate variability (HRV) (–0.29%; 95% CI: –0.55, –0.04), while respiratory rate, wrist skin temperature, and sleep duration remained unchanged. Restricting exposure to nocturnal Foehn strengthened the associations with HR (+ 0.41 bpm; 95% CI: 0.31, 0.50) and HRV (–0.35%; 95% CI: –0.66, –0.05), whereas both were attenuated after additional adjustment for air temperature, humidity and barometric pressure. Overall, 40.8% of participants reported impaired well-being during Foehn episodes. These individuals showed a 9.92% lower PI irrespective of Foehn and less pronounced Foehn-related changes in HR (+ 0.15 vs. + 0.32 bpm) and HRV (+ 0.04% vs. –0.53%).</p><h3>Conclusions</h3><p>Our findings provide evidence that Foehn winds are linked to objectively measurable changes in physiological parameters, which appear attributable to the accompanying meteorological conditions. Individuals reporting impaired well-being during Foehn showed a lower baseline perfusion index but weaker physiological responses.</p></div>","PeriodicalId":588,"journal":{"name":"International Journal of Biometeorology","volume":"70 10","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2026-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Biometeorology","FirstCategoryId":"89","ListUrlMain":"https://link.springer.com/article/10.1007/s00484-026-03327-w","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Foehn winds, warm and dry downslope winds common in alpine regions, have long been suspected to affect human health, but objective evidence remains limited. Wearable devices now allow physiological responses to such conditions to be captured. This study investigates the association between Foehn winds and changes in physiological parameters.
Methods
Healthy adults in Liechtenstein wore a medical sensory wearable device during sleep over an 11-month period. Nightly physiological parameters were related to Foehn exposure in linear mixed-effects models.
Results
714 participants (59.7% women; mean age 44.0 years) were included. Foehn was associated with changes in heart rate (HR) (+ 0.25 bpm; 95% CI: 0.17, 0.33), perfusion index (PI) (+ 0.78%; 95% CI: 0.22, 1.33), and heart rate variability (HRV) (–0.29%; 95% CI: –0.55, –0.04), while respiratory rate, wrist skin temperature, and sleep duration remained unchanged. Restricting exposure to nocturnal Foehn strengthened the associations with HR (+ 0.41 bpm; 95% CI: 0.31, 0.50) and HRV (–0.35%; 95% CI: –0.66, –0.05), whereas both were attenuated after additional adjustment for air temperature, humidity and barometric pressure. Overall, 40.8% of participants reported impaired well-being during Foehn episodes. These individuals showed a 9.92% lower PI irrespective of Foehn and less pronounced Foehn-related changes in HR (+ 0.15 vs. + 0.32 bpm) and HRV (+ 0.04% vs. –0.53%).
Conclusions
Our findings provide evidence that Foehn winds are linked to objectively measurable changes in physiological parameters, which appear attributable to the accompanying meteorological conditions. Individuals reporting impaired well-being during Foehn showed a lower baseline perfusion index but weaker physiological responses.
期刊介绍:
The Journal publishes original research papers, review articles and short communications on studies examining the interactions between living organisms and factors of the natural and artificial atmospheric environment.
Living organisms extend from single cell organisms, to plants and animals, including humans. The atmospheric environment includes climate and weather, electromagnetic radiation, and chemical and biological pollutants. The journal embraces basic and applied research and practical aspects such as living conditions, agriculture, forestry, and health.
The journal is published for the International Society of Biometeorology, and most membership categories include a subscription to the Journal.