[Application of 3D printing technology in minimally invasive treatment of Sanders typeⅡ-Ⅲ calcaneal fractures].

Q4 Medicine
Yimeng Wu, Dawei Zhao, Guangrong Yu, Xiaoyan Mao, Haiting Li, Yingjie Zhu
{"title":"[Application of 3D printing technology in minimally invasive treatment of Sanders typeⅡ-Ⅲ calcaneal fractures].","authors":"Yimeng Wu, Dawei Zhao, Guangrong Yu, Xiaoyan Mao, Haiting Li, Yingjie Zhu","doi":"10.12200/j.issn.1003-0034.20250498","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To explore clinical efficacy of 3D-printed guide plates combined with expansion screw internal fixation in treating Sanders typeⅡand Ⅲ calcaneal fractures.</p><p><strong>Methods: </strong>From March 2021 to October 2024, 60 patients with Sanders typeⅡand Ⅲ calcaneal fractures were admitted and divided into 3D printing group and closed reduction group based on different surgical methods. There were 32 patients in 3D printing group, including 28 males and 4 females;aged from 31 to 43 years old with an average of (37.2±4.1) years old;the course of disease ranged from 1.2 to 5.0 days with an average of (3.8±1.8) days;17 patients with typeⅡand 15 patients with type Ⅲ according to Sanders classification;treated with closed reduction with screws using custom-made guides printed by 3D technology in combination with expanders. There were 28 patients in closed reduction group, including 25 males and 3 females;aged from 29 to 41 years old with an average of (36.0±5.3) years old;the course of disease ranged from 2.8 to 4.8 days with an average of (4.1±1.2) days;16 patients with typeⅡand 12 patients with type Ⅲ according to Sanders classification;treated with simple distraction device for closed reduction and screw fixation. Operation time, fluoroscopy frequency, blood loss, the changes in Böhler angle, Gissane angle were compared;preoperative and postoperative calcaneal width of talus, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score at 6 months were compared.</p><p><strong>Results: </strong>Both groups of patients were followed up for 6 to 10 months with an average of (8.4±0.9) months. There were no complications such as infection, skin necrosis, or non-healing of fractures in either group after operation. Operation time, intraoperative blood loss and fluoroscopy frequency of 3D printing group were (51.2±6.8) min, (22.4±5.3) mL and(18.3±4.2) respectively, which were all better than those of closed reduction group(63.5±8.2) min, (39.6±7.1) mL, (34.5±5.8), and the differences were statistically significant (<i>P</i><0.05). Preoperative Böhler angle, Gissane angle and calcaneal width of 3D printing group and closed reduction group were[(13.9±6.2)° <i>vs.</i> (12.6±5.8)°], [(150.2±3.8)° <i>vs.</i> (149.3±4.5)°], and [(44.2±1.8) mm <i>vs.</i> (42.8±1.6) mm] respectively;and [(27.5±7.1)° <i>vs.</i> (26.8±6.9)°], [(125.7±2.1)° <i>vs.</i> (123.4±1.5)°], and [(38.2±1.2) mm <i>vs.</i> (37.5±0.9) mm] respectively at 6 months after operation;Böhler angle, Gissane angle and calcaneal width of both groups at 6 months after operation were significantly improved compared with those of before operation (<i>P</i><0.05). Postoperative AOFAS ankle-hindfoot scores of both groups at 6 months showed significant improvement compared to those of before operation (<i>P</i><0.05), and there was no statistically significant difference between two groups (<i>P</i>>0.05). According to postoperative AOFAS ankle-hindfoot scores at 6 months, in 3D printing group, outcomes were rated as excellent in 12 patients, good in 20 patients;in closed reduction group, outcomes were rated as excellent in 7 patients, good in 21 patients.</p><p><strong>Conclusion: </strong>3D-printed guide plate combined with expansion screw internal fixation for treating Sanders typeⅡand Ⅲ calcaneal fractures has advantages of short operation time, less bleeding, and fewer fluoroscopic examinations. It is conducive to the rapid operation of physicians and reduces trauma and radiation to the patients.</p>","PeriodicalId":23964,"journal":{"name":"Zhongguo gu shang = China journal of orthopaedics and traumatology","volume":"39 9","pages":"888-94"},"PeriodicalIF":0.0000,"publicationDate":"2026-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhongguo gu shang = China journal of orthopaedics and traumatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12200/j.issn.1003-0034.20250498","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To explore clinical efficacy of 3D-printed guide plates combined with expansion screw internal fixation in treating Sanders typeⅡand Ⅲ calcaneal fractures.

Methods: From March 2021 to October 2024, 60 patients with Sanders typeⅡand Ⅲ calcaneal fractures were admitted and divided into 3D printing group and closed reduction group based on different surgical methods. There were 32 patients in 3D printing group, including 28 males and 4 females;aged from 31 to 43 years old with an average of (37.2±4.1) years old;the course of disease ranged from 1.2 to 5.0 days with an average of (3.8±1.8) days;17 patients with typeⅡand 15 patients with type Ⅲ according to Sanders classification;treated with closed reduction with screws using custom-made guides printed by 3D technology in combination with expanders. There were 28 patients in closed reduction group, including 25 males and 3 females;aged from 29 to 41 years old with an average of (36.0±5.3) years old;the course of disease ranged from 2.8 to 4.8 days with an average of (4.1±1.2) days;16 patients with typeⅡand 12 patients with type Ⅲ according to Sanders classification;treated with simple distraction device for closed reduction and screw fixation. Operation time, fluoroscopy frequency, blood loss, the changes in Böhler angle, Gissane angle were compared;preoperative and postoperative calcaneal width of talus, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score at 6 months were compared.

Results: Both groups of patients were followed up for 6 to 10 months with an average of (8.4±0.9) months. There were no complications such as infection, skin necrosis, or non-healing of fractures in either group after operation. Operation time, intraoperative blood loss and fluoroscopy frequency of 3D printing group were (51.2±6.8) min, (22.4±5.3) mL and(18.3±4.2) respectively, which were all better than those of closed reduction group(63.5±8.2) min, (39.6±7.1) mL, (34.5±5.8), and the differences were statistically significant (P<0.05). Preoperative Böhler angle, Gissane angle and calcaneal width of 3D printing group and closed reduction group were[(13.9±6.2)° vs. (12.6±5.8)°], [(150.2±3.8)° vs. (149.3±4.5)°], and [(44.2±1.8) mm vs. (42.8±1.6) mm] respectively;and [(27.5±7.1)° vs. (26.8±6.9)°], [(125.7±2.1)° vs. (123.4±1.5)°], and [(38.2±1.2) mm vs. (37.5±0.9) mm] respectively at 6 months after operation;Böhler angle, Gissane angle and calcaneal width of both groups at 6 months after operation were significantly improved compared with those of before operation (P<0.05). Postoperative AOFAS ankle-hindfoot scores of both groups at 6 months showed significant improvement compared to those of before operation (P<0.05), and there was no statistically significant difference between two groups (P>0.05). According to postoperative AOFAS ankle-hindfoot scores at 6 months, in 3D printing group, outcomes were rated as excellent in 12 patients, good in 20 patients;in closed reduction group, outcomes were rated as excellent in 7 patients, good in 21 patients.

Conclusion: 3D-printed guide plate combined with expansion screw internal fixation for treating Sanders typeⅡand Ⅲ calcaneal fractures has advantages of short operation time, less bleeding, and fewer fluoroscopic examinations. It is conducive to the rapid operation of physicians and reduces trauma and radiation to the patients.

[3D打印技术在Sanders型Ⅱ-Ⅲ跟骨骨折微创治疗中的应用]。
目的:探讨3d打印导板联合膨胀螺钉内固定治疗Sanders型Ⅱ、Ⅲ跟骨骨折的临床疗效。方法:选取2021年3月至2024年10月收治的60例Sanders型Ⅱ、Ⅲ跟骨骨折患者,根据手术方式的不同分为3D打印组和闭合复位组。3D打印组32例,其中男性28例,女性4例;年龄31 ~ 43岁,平均(37.2±4.1)岁;病程1.2 ~ 5.0 d,平均(3.8±1.8)d;Sanders分型:Ⅱ型17例,Ⅲ型15例;使用由3D技术结合膨胀器打印的定制导轨进行螺钉闭合复位处理。闭合复位组28例,其中男25例,女3例;年龄29 ~ 41岁,平均(36.0±5.3)岁;病程2.8 ~ 4.8天,平均(4.1±1.2)天;Sanders分型:Ⅱ型16例,Ⅲ型12例;采用简易牵张器闭合复位螺钉固定。比较手术时间、透视次数、出血量、Böhler角、Gissane角的变化情况;比较术前、术后距骨跟宽度、美国矫形足踝学会(AOFAS) 6个月踝关节-后足评分。结果:两组患者随访6 ~ 10个月,平均(8.4±0.9)个月。两组患者术后均无感染、皮肤坏死、骨折不愈合等并发症。3D打印组手术时间、术中出血量、透视次数分别为(51.2±6.8)min、(22.4±5.3)mL、(18.3±4.2)次,均优于闭合复位组(63.5±8.2)min、(39.6±7.1)mL、(34.5±5.8)次,差异均有统计学意义(p < 0.05)。(12.6±5.8)°]、[(150.2±3.8)°和(149.3±4.5)°),和[(44.2±1.8)毫米和(42.8±1.6)毫米)分别;和[(27.5±7.1)°和(26.8±6.9)°],[(125.7±2.1)°和(123.4±1.5)°),和[(38.2±1.2)毫米和(37.5±0.9)毫米)分别在术后6个月;术后6个月两组与术前相比,Böhler角、Gissane角、跟骨宽度均有显著改善(PPP>0.05)。根据术后6个月AOFAS踝关节-后足评分,3D打印组12例为优,20例为良;闭合复位组7例为优,21例为良。结论:3d打印导板联合膨胀螺钉内固定治疗Sanders型Ⅱ、Ⅲ跟骨骨折具有手术时间短、出血少、透视检查少等优点。有利于医生快速手术,减少对患者的创伤和辐射。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
189
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书