Procedural and Functional Outcomes After Computer Assisted Vacuum Thrombectomy With the 16F Catheter System for Treatment of Pulmonary Embolism: A Subanalysis of the STRIKE-PE Study.
John M Moriarty, Brian J Schiro, Ido Weinberg, Suhail Y Dohad, Hugh C Davis, David M Shavelle, George S Chrysant, Paul E Perkowski, Patrick E Muck, Vivian L Bishay, Andrew Holden, Frances M West, Matthew J Scheidt, Sanjum S Sethi, W Brent Keeling, Aleksander Araszkiewicz
{"title":"Procedural and Functional Outcomes After Computer Assisted Vacuum Thrombectomy With the 16F Catheter System for Treatment of Pulmonary Embolism: A Subanalysis of the STRIKE-PE Study.","authors":"John M Moriarty, Brian J Schiro, Ido Weinberg, Suhail Y Dohad, Hugh C Davis, David M Shavelle, George S Chrysant, Paul E Perkowski, Patrick E Muck, Vivian L Bishay, Andrew Holden, Frances M West, Matthew J Scheidt, Sanjum S Sethi, W Brent Keeling, Aleksander Araszkiewicz","doi":"10.1016/j.jvir.2026.109100","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This subanalysis of the STRIKE-PE study evaluates use of computer assisted vacuum thrombectomy (CAVT), a form of endovascular therapy for acute pulmonary embolism (PE), with the 16F catheter system.</p><p><strong>Materials and methods: </strong>This subanalysis from a prespecified interim analysis reports procedural outcomes and functional outcomes to 90 days from the first 244 patients treated using the 16F catheter system in STRIKE-PE, an ongoing single-arm, prospective, global study evaluating safety, effectiveness, and outcomes after CAVT in patients with acute PE. The primary end points of STRIKE-PE are change in right-to-left ventricular (RV/LV) ratio from baseline to 48-hour follow-up and composite major adverse event (MAE) rate within 48 hours.</p><p><strong>Results: </strong>Mean RV/LV ratio at baseline was 1.34, which decreased to 0.95 at 48 hours postprocedure (27.3% reduction; P < .001). The composite MAE rate within 48 hours was 0.8%. Procedural results included a reduction in mean on-table systolic pulmonary artery pressure (23.6% reduction; P < .001) and a median thrombectomy time of 25 minutes. The functional outcome assessments of Borg dyspnea scale (P < .001) and 6-minute walk test distance (P < .001) progressively improved to 90 days. New York Heart Association (NYHA) class I or none increased from 67.4% of patients at discharge to 82.9% at 90-day follow-up (P < .001).</p><p><strong>Conclusions: </strong>Treatment of PE with CAVT using the 16F catheter system was associated with statistically significant improvement in right heart function, hemodynamics, dyspnea, and distance walked; additionally, NYHA class recovered. The device had a short procedure time and a low composite MAE rate.</p>","PeriodicalId":49962,"journal":{"name":"Journal of Vascular and Interventional Radiology","volume":" ","pages":"109100"},"PeriodicalIF":3.1000,"publicationDate":"2026-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vascular and Interventional Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jvir.2026.109100","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This subanalysis of the STRIKE-PE study evaluates use of computer assisted vacuum thrombectomy (CAVT), a form of endovascular therapy for acute pulmonary embolism (PE), with the 16F catheter system.
Materials and methods: This subanalysis from a prespecified interim analysis reports procedural outcomes and functional outcomes to 90 days from the first 244 patients treated using the 16F catheter system in STRIKE-PE, an ongoing single-arm, prospective, global study evaluating safety, effectiveness, and outcomes after CAVT in patients with acute PE. The primary end points of STRIKE-PE are change in right-to-left ventricular (RV/LV) ratio from baseline to 48-hour follow-up and composite major adverse event (MAE) rate within 48 hours.
Results: Mean RV/LV ratio at baseline was 1.34, which decreased to 0.95 at 48 hours postprocedure (27.3% reduction; P < .001). The composite MAE rate within 48 hours was 0.8%. Procedural results included a reduction in mean on-table systolic pulmonary artery pressure (23.6% reduction; P < .001) and a median thrombectomy time of 25 minutes. The functional outcome assessments of Borg dyspnea scale (P < .001) and 6-minute walk test distance (P < .001) progressively improved to 90 days. New York Heart Association (NYHA) class I or none increased from 67.4% of patients at discharge to 82.9% at 90-day follow-up (P < .001).
Conclusions: Treatment of PE with CAVT using the 16F catheter system was associated with statistically significant improvement in right heart function, hemodynamics, dyspnea, and distance walked; additionally, NYHA class recovered. The device had a short procedure time and a low composite MAE rate.
期刊介绍:
JVIR, published continuously since 1990, is an international, monthly peer-reviewed interventional radiology journal. As the official journal of the Society of Interventional Radiology, JVIR is the peer-reviewed journal of choice for interventional radiologists, radiologists, cardiologists, vascular surgeons, neurosurgeons, and other clinicians who seek current and reliable information on every aspect of vascular and interventional radiology. Each issue of JVIR covers critical and cutting-edge medical minimally invasive, clinical, basic research, radiological, pathological, and socioeconomic issues of importance to the field.