Equation Disagreement as a Zero-Cost Uncertainty Signal for LDL-C Classification: An Interpretable Regime-Aware Calibration Model Rescues Misclassification at Treatment Thresholds.

IF 2.3 Q3 MEDICAL LABORATORY TECHNOLOGY
Ronald Doku, Nana Yaw A Osafo, John Kwagyan, William M Southerland
{"title":"Equation Disagreement as a Zero-Cost Uncertainty Signal for LDL-C Classification: An Interpretable Regime-Aware Calibration Model Rescues Misclassification at Treatment Thresholds.","authors":"Ronald Doku, Nana Yaw A Osafo, John Kwagyan, William M Southerland","doi":"10.1093/jalm/jfag139","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Three LDL cholesterol (LDL-C) estimation equations (Friedewald, Sampson/NIH, and Martin-Hopkins) can be calculated from every standard lipid panel, yet laboratories typically report only one. We tested whether disagreement identifies misclassification risk at clinical thresholds and whether simple calibration improves accuracy in this subgroup.</p><p><strong>Methods: </strong>We analyzed 10 799 All of Us lipid panels using direct LDL-C as the reference standard. At 70, 100, and 130 mg/dL [1.81, 2.59, and 3.36 mmol/L], panels were classified as Agree if all 3 equations fell on the same side and Disagree otherwise. A regime-aware calibration model was compared with 7 machine learning (ML) methods using 5-fold cross-validation and tested in 14 549 hospital-based Medical Information Mart for Intensive Care IV panels.</p><p><strong>Results: </strong>When equations agreed (86%-92% of panels), accuracy was 92% to 96%; when they disagreed (8%-14%), accuracy fell to 48%-61%. The model's mean absolute error was 8.98 mg/dL (0.232 mmol/L), matching the best ML ensemble (9.01 mg/dL [0.233 mmol/L]; 95% CI for the difference, -0.35 to 0.29 mg/dL [-0.009 to 0.008 mmol/L]). In external validation, among split-threshold panels, the model outperformed the best-performing individual equation at each threshold by 3.5 to 9.0 percentage points and the majority vote by 18.5 to 25.2 percentage points. Calibration improved accuracy by 19 to 25 percentage points; hybrid routing achieved 90%-93% accuracy internally and 90%-94% externally.</p><p><strong>Conclusions: </strong>Equation disagreement is a zero-cost uncertainty signal identifying patients at highest misclassification risk. A simple, interpretable calibration model improves classification while matching the best-performing ML ensemble.</p>","PeriodicalId":46361,"journal":{"name":"Journal of Applied Laboratory Medicine","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2026-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jalm/jfag139","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Three LDL cholesterol (LDL-C) estimation equations (Friedewald, Sampson/NIH, and Martin-Hopkins) can be calculated from every standard lipid panel, yet laboratories typically report only one. We tested whether disagreement identifies misclassification risk at clinical thresholds and whether simple calibration improves accuracy in this subgroup.

Methods: We analyzed 10 799 All of Us lipid panels using direct LDL-C as the reference standard. At 70, 100, and 130 mg/dL [1.81, 2.59, and 3.36 mmol/L], panels were classified as Agree if all 3 equations fell on the same side and Disagree otherwise. A regime-aware calibration model was compared with 7 machine learning (ML) methods using 5-fold cross-validation and tested in 14 549 hospital-based Medical Information Mart for Intensive Care IV panels.

Results: When equations agreed (86%-92% of panels), accuracy was 92% to 96%; when they disagreed (8%-14%), accuracy fell to 48%-61%. The model's mean absolute error was 8.98 mg/dL (0.232 mmol/L), matching the best ML ensemble (9.01 mg/dL [0.233 mmol/L]; 95% CI for the difference, -0.35 to 0.29 mg/dL [-0.009 to 0.008 mmol/L]). In external validation, among split-threshold panels, the model outperformed the best-performing individual equation at each threshold by 3.5 to 9.0 percentage points and the majority vote by 18.5 to 25.2 percentage points. Calibration improved accuracy by 19 to 25 percentage points; hybrid routing achieved 90%-93% accuracy internally and 90%-94% externally.

Conclusions: Equation disagreement is a zero-cost uncertainty signal identifying patients at highest misclassification risk. A simple, interpretable calibration model improves classification while matching the best-performing ML ensemble.

方程不一致作为LDL-C分类的零成本不确定性信号:一个可解释的制度感知校准模型在处理阈值处拯救错误分类。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Applied Laboratory Medicine
Journal of Applied Laboratory Medicine MEDICAL LABORATORY TECHNOLOGY-
CiteScore
3.70
自引率
5.00%
发文量
137
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书