{"title":"Asymmetric Flow Dynamics in a Pneumatically Actuated Polydimethylsiloxane (PDMS) Micropump: Numerical Simulation and Experimental Validation.","authors":"Pei-Pei Hsu, Jr-Lung Lin","doi":"10.3390/mi17091027","DOIUrl":null,"url":null,"abstract":"<p><p>This study presents a comprehensive numerical and experimental investigation on a pneumatically actuated polydimethylsiloxane (PDMS) micropump integrated with passive check valves (PCVs). Advanced three-dimensional (3D) fluid-structure interaction (FSI) simulations were conducted to capture the nonlinear large deformation of the membrane and elucidate the Newtonian flow dynamics. The maximum deformation calculated by the simulations was compared with the theoretical Timoshenko formula, demonstrating excellent agreement across the entire pressure range (3.0-100.0 kPa). The 3D FSI simulations revealed a considerable asymmetry in the flow dynamics between the suction and compression phases. Notably, at applied pressures exceeding 20.0 kPa, the discharge volume substantially outweighed the suction one. To characterize both the ideal and practical volumetric flow rates, curve-fitting analyses revealed that both the simulation and experimental data follow a consistent 1/3-power-law relationship with respect to the applied pressure. Experimentally, the micropump achieved a maximum volumetric flow rate of 2.6 mL/min at 70.0 kPa and 12.0 Hz. Furthermore, the micropump demonstrated a peak pumping efficiency of 56.95% at 35.0 kPa and 10.0 Hz relative to the ideal numerical baseline. By bridging idealized numerical bounds with experimental realities, this validated framework offers a robust predictive tool for optimizing flow asymmetry and pumping efficiency in advanced microfluidic systems.</p>","PeriodicalId":18508,"journal":{"name":"Micromachines","volume":"17 9","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2026-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13609855/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micromachines","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/mi17091027","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study presents a comprehensive numerical and experimental investigation on a pneumatically actuated polydimethylsiloxane (PDMS) micropump integrated with passive check valves (PCVs). Advanced three-dimensional (3D) fluid-structure interaction (FSI) simulations were conducted to capture the nonlinear large deformation of the membrane and elucidate the Newtonian flow dynamics. The maximum deformation calculated by the simulations was compared with the theoretical Timoshenko formula, demonstrating excellent agreement across the entire pressure range (3.0-100.0 kPa). The 3D FSI simulations revealed a considerable asymmetry in the flow dynamics between the suction and compression phases. Notably, at applied pressures exceeding 20.0 kPa, the discharge volume substantially outweighed the suction one. To characterize both the ideal and practical volumetric flow rates, curve-fitting analyses revealed that both the simulation and experimental data follow a consistent 1/3-power-law relationship with respect to the applied pressure. Experimentally, the micropump achieved a maximum volumetric flow rate of 2.6 mL/min at 70.0 kPa and 12.0 Hz. Furthermore, the micropump demonstrated a peak pumping efficiency of 56.95% at 35.0 kPa and 10.0 Hz relative to the ideal numerical baseline. By bridging idealized numerical bounds with experimental realities, this validated framework offers a robust predictive tool for optimizing flow asymmetry and pumping efficiency in advanced microfluidic systems.

气动驱动聚二甲基硅氧烷(PDMS)微泵中的不对称流动动力学:数值模拟和实验验证。
本文对气动驱动的聚二甲基硅氧烷(PDMS)微泵与被动止回阀(pcv)集成进行了全面的数值和实验研究。采用先进的三维流固相互作用(FSI)模拟技术,捕捉膜的非线性大变形,阐明牛顿流体动力学。将模拟计算的最大变形与理论Timoshenko公式进行了比较,结果表明,在整个压力范围(3.0-100.0 kPa)内,最大变形与理论Timoshenko公式非常吻合。三维FSI模拟显示,在吸力和压缩阶段之间的流动动力学具有相当大的不对称性。值得注意的是,当施加的压力超过20.0千帕时,排出量大大超过吸入量。为了描述理想和实际体积流量,曲线拟合分析表明,模拟和实验数据都遵循与施加压力一致的1/3幂律关系。实验结果表明,该微泵在70.0 kPa和12.0 Hz下的最大体积流量为2.6 mL/min。此外,相对于理想数值基线,微泵在35.0 kPa和10.0 Hz下的峰值泵送效率为56.95%。通过将理想的数值边界与实验现实相结合,该验证框架为优化先进微流体系统中的流动不对称性和泵送效率提供了强大的预测工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Micromachines
Micromachines NANOSCIENCE & NANOTECHNOLOGY-INSTRUMENTS & INSTRUMENTATION
CiteScore
5.20
自引率
14.70%
发文量
1862
审稿时长
16.31 days
期刊介绍: Micromachines (ISSN 2072-666X) is an international, peer-reviewed open access journal which provides an advanced forum for studies related to micro-scaled machines and micromachinery. It publishes reviews, regular research papers and short communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书