Geometric Determinants of Post-stenotic Energetics in Coarctation of Aorta: Linking Centerline Morphology to Downstream Energy Loss.

IF 5.2 2区 医学 Q3 ENGINEERING, BIOMEDICAL
MohammadAli Daeian, Arsha Karbassi, Javier Ganame, Spencer Smith, Zahra Keshavarz-Motamed
{"title":"Geometric Determinants of Post-stenotic Energetics in Coarctation of Aorta: Linking Centerline Morphology to Downstream Energy Loss.","authors":"MohammadAli Daeian, Arsha Karbassi, Javier Ganame, Spencer Smith, Zahra Keshavarz-Motamed","doi":"10.1007/s10439-026-04351-y","DOIUrl":null,"url":null,"abstract":"<p><p>While pressure gradient remains the clinical gold standard for diagnosing coarctation of the aorta (CoA), it does not fully capture the complexity of post-stenotic flow behavior, particularly the elevated energy dissipation downstream of the coarctation arising from complex anatomy and flow dynamics. This study investigates the relationship between coarctation and descending aorta anatomy, post-stenotic flow energy loss, and its association with left ventricular (LV) workload. A cohort of 20 CoA patients was analyzed. Anatomical features, including centerline topology and cross-sectional area variation along the descending aorta, were extracted from CT and MRI images. Patient-specific multiscale computational simulations were employed to quantify three-dimensional aortic hemodynamics, cardiac function, and systemic hemodynamics. Results demonstrate that energy dissipation per unit volume in the descending aorta correlates with the combined effect of the kinetic energy available at the coarctation site and the centerline tangent angle difference between the coarctation site and the downstream descending aorta. These parameters were also found to significantly influence LV workload expended for post-stenotic energy loss. This study underscores the critical role of descending aorta anatomy in shaping post-coarctation flow energetics and highlights the importance of incorporating anatomical and energetic metrics alongside pressure gradients to better assess disease severity and cardiac burden in CoA patients.</p>","PeriodicalId":7986,"journal":{"name":"Annals of Biomedical Engineering","volume":" ","pages":""},"PeriodicalIF":5.2000,"publicationDate":"2026-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10439-026-04351-y","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

While pressure gradient remains the clinical gold standard for diagnosing coarctation of the aorta (CoA), it does not fully capture the complexity of post-stenotic flow behavior, particularly the elevated energy dissipation downstream of the coarctation arising from complex anatomy and flow dynamics. This study investigates the relationship between coarctation and descending aorta anatomy, post-stenotic flow energy loss, and its association with left ventricular (LV) workload. A cohort of 20 CoA patients was analyzed. Anatomical features, including centerline topology and cross-sectional area variation along the descending aorta, were extracted from CT and MRI images. Patient-specific multiscale computational simulations were employed to quantify three-dimensional aortic hemodynamics, cardiac function, and systemic hemodynamics. Results demonstrate that energy dissipation per unit volume in the descending aorta correlates with the combined effect of the kinetic energy available at the coarctation site and the centerline tangent angle difference between the coarctation site and the downstream descending aorta. These parameters were also found to significantly influence LV workload expended for post-stenotic energy loss. This study underscores the critical role of descending aorta anatomy in shaping post-coarctation flow energetics and highlights the importance of incorporating anatomical and energetic metrics alongside pressure gradients to better assess disease severity and cardiac burden in CoA patients.

主动脉缩窄中狭窄后能量的几何决定因素:将中心线形态与下游能量损失联系起来。
虽然压力梯度仍然是诊断主动脉缩窄(CoA)的临床金标准,但它并不能完全反映狭窄后血流行为的复杂性,特别是由于复杂的解剖和血流动力学引起的缩窄下游能量耗散升高。本研究探讨了缩窄与降主动脉解剖、狭窄后血流能量损失及其与左心室负荷的关系。对20例CoA患者进行队列分析。从CT和MRI图像中提取解剖特征,包括中心线拓扑和沿降主动脉的横截面积变化。采用患者特异性的多尺度计算模拟来量化三维主动脉血流动力学、心功能和全身血流动力学。结果表明,降主动脉单位体积能量耗散与缩窄部位可用动能和缩窄部位与下游降主动脉中心线相切角差的综合作用有关。这些参数也被发现显著影响狭窄后能量损失的左室工作量消耗。本研究强调了降主动脉解剖在形成缩窄后血流能量学中的关键作用,并强调了将解剖和能量指标与压力梯度结合起来以更好地评估CoA患者疾病严重程度和心脏负担的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of Biomedical Engineering
Annals of Biomedical Engineering 工程技术-工程:生物医学
CiteScore
7.50
自引率
15.80%
发文量
212
审稿时长
3 months
期刊介绍: Annals of Biomedical Engineering is an official journal of the Biomedical Engineering Society, publishing original articles in the major fields of bioengineering and biomedical engineering. The Annals is an interdisciplinary and international journal with the aim to highlight integrated approaches to the solutions of biological and biomedical problems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书