Optimization of the Nitinol Framework of an Aortic Valve Bioprosthesis Using Numerical Simulation.

Sovremennye tekhnologii v meditsine Pub Date : 2026-01-01 Epub Date: 2026-08-31 DOI:10.17691/stm2026.18.4.02
S V Vladimirov, Yu M Prikhodko, V V Khakhalkin, V P Borodin, A B Mochalova, A V Bogachev-Prokofiev
{"title":"Optimization of the Nitinol Framework of an Aortic Valve Bioprosthesis Using Numerical Simulation.","authors":"S V Vladimirov, Yu M Prikhodko, V V Khakhalkin, V P Borodin, A B Mochalova, A V Bogachev-Prokofiev","doi":"10.17691/stm2026.18.4.02","DOIUrl":null,"url":null,"abstract":"<p><p>The application of numerical analysis methods when developing novel heart valve bioprostheses is an integral stage of their design; it enables to optimize the bioprosthetic construction and accelerate their development process. <b>The aim of the study</b> was to conduct hydrodynamic tests of a prototype of a self-expandable transcatheter aortic valve bioprosthesis and, based on the findings, using numerical simulation, improve the geometry of the bioprosthetic nitinol frame.</p><p><strong>Materials and methods: </strong>The study investigated an aortic valve bioprosthesis with a self-expanding nitinol frame and the leaflet apparatus of three biological leaflets fixed to the frame through the holes in the commissural posts. The bioprosthesis was tested on a test bench to evaluate the hydrodynamic characteristics of heart valve prostheses. A computer model of the valve frame was created for a finite element analysis in the COMSOL Multiphysics software environment, and validated based on the observed deformations of the bioprosthesis in a full-scale experiment. The obtained model was used for parametric optimization of the commissural post geometry to reduce their deformities.</p><p><strong>Results: </strong>Bench hydrodynamic tests revealed significant deformities of the bioprosthetic commissural posts (bending up to 5 mm) in leaflet closure under diastolic pressure. The numerical simulation using the finite element method enabled to precise the load on the posts (1.3 N instead of 1.52 N according to preliminary calculations). Based on the results obtained, an optimized frame design was developed with increased width and thickness of the beams in the area of commissural posts (from 0.3 to 0.5 mm and from 0.4 to 0.5 mm, respectively). Finite element analysis showed the suggested modification to significantly increase the structural stiffness, reducing the deformation value to 0.7 mm under the load of 1.3 N.</p><p><strong>Conclusion: </strong>The suggested approach to the application of numerical simulation demonstrated its effectiveness for optimizing the design of the nitinol frame of a transcatheter aortic valve bioprosthesis. The suggested modification of the commissural post geometry significantly reduced their deformity under the hydrodynamic load on the valve, which contributed to the preservation of the leaflet coaptation, reduced the risk of paravalvular regurgitation and prosthesis dislocation. The findings demonstrate the promise of using numerical simulation methods at a bioprosthetic design stage enabling to reduce the number of necessary physical prototypes and accelerate the development process.</p>","PeriodicalId":520289,"journal":{"name":"Sovremennye tekhnologii v meditsine","volume":"18 4","pages":"14-20"},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13602026/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sovremennye tekhnologii v meditsine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17691/stm2026.18.4.02","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/31 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The application of numerical analysis methods when developing novel heart valve bioprostheses is an integral stage of their design; it enables to optimize the bioprosthetic construction and accelerate their development process. The aim of the study was to conduct hydrodynamic tests of a prototype of a self-expandable transcatheter aortic valve bioprosthesis and, based on the findings, using numerical simulation, improve the geometry of the bioprosthetic nitinol frame.

Materials and methods: The study investigated an aortic valve bioprosthesis with a self-expanding nitinol frame and the leaflet apparatus of three biological leaflets fixed to the frame through the holes in the commissural posts. The bioprosthesis was tested on a test bench to evaluate the hydrodynamic characteristics of heart valve prostheses. A computer model of the valve frame was created for a finite element analysis in the COMSOL Multiphysics software environment, and validated based on the observed deformations of the bioprosthesis in a full-scale experiment. The obtained model was used for parametric optimization of the commissural post geometry to reduce their deformities.

Results: Bench hydrodynamic tests revealed significant deformities of the bioprosthetic commissural posts (bending up to 5 mm) in leaflet closure under diastolic pressure. The numerical simulation using the finite element method enabled to precise the load on the posts (1.3 N instead of 1.52 N according to preliminary calculations). Based on the results obtained, an optimized frame design was developed with increased width and thickness of the beams in the area of commissural posts (from 0.3 to 0.5 mm and from 0.4 to 0.5 mm, respectively). Finite element analysis showed the suggested modification to significantly increase the structural stiffness, reducing the deformation value to 0.7 mm under the load of 1.3 N.

Conclusion: The suggested approach to the application of numerical simulation demonstrated its effectiveness for optimizing the design of the nitinol frame of a transcatheter aortic valve bioprosthesis. The suggested modification of the commissural post geometry significantly reduced their deformity under the hydrodynamic load on the valve, which contributed to the preservation of the leaflet coaptation, reduced the risk of paravalvular regurgitation and prosthesis dislocation. The findings demonstrate the promise of using numerical simulation methods at a bioprosthetic design stage enabling to reduce the number of necessary physical prototypes and accelerate the development process.

应用数值模拟优化钛钛合金主动脉瓣生物假体框架。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书