{"title":"Feasibility of Applying Proton Minibeam Technology on the Proton Therapy Complex \"Prometheus\".","authors":"O Yu Golovanova, G V Merzlikin, A D Kaprin, A N Soloviev, V O Saburov, S N Koryakin","doi":"10.17691/stm2026.18.4.01","DOIUrl":null,"url":null,"abstract":"<p><p>Spatial fractionation of proton beams is being considered as a new strategy to reduce the probability of side-effects in radiation therapy on the proton therapy complex (PTC) \"Prometheus\". By collimating the beams to submillimeter dimensions, the dose profile at the target surface consists of alternating high- and low-dose regions. This promotes sparing of normal tissues along the beam path through the activation of various biological mechanisms. <b>The aim of the study</b> was to implement the minibeam method on the PTC \"Prometheus\" and to experimentally assess the quality of the resulting dose distribution.</p><p><strong>Materials and methods: </strong>Collimation of the primary beam was achieved using brass multislit collimators. Mathematical modeling of the experiment was performed, and a phantom was irradiated from one and from two opposite directions. For effective summation of two fields and to achieve a homogeneous dose distribution in the target, intensity and energy modulation of the proton beams entering the collimator was carried out. To reduce errors caused by collimator deviation relative to the beam axis, a quality assurance system for collimator positioning on the treatment table was developed. Under the control of a scintillation detector and a laser positioner, positioning accuracy was within 0.2°. GafChromic EBT3 radiochromic films (Ashland, USA) were used as dosimeters.</p><p><strong>Results: </strong>When comparing calculated and experimental data, 90% of the distribution points matched the mathematical model according to the γ criterion (3%/3 mm). The quality of the minibeam field was assessed using the following parameters: valley-to-peak dose ratio; collimator throughput; ratio of the dose without the collimator to the dose with the collimator; and dose homogeneity index in the target. The obtained results met the quality assurance criteria for standard radiation therapy.</p><p><strong>Conclusion: </strong>Irradiation with proton minibeams using brass collimators is feasible on the PTC \"Prometheus\". A uniform dose distribution in the target area was experimentally achieved. The uniformity of coverage, the absence of local dose excesses, and the high dose gradient at the distal edge suggest that the described irradiation technique can be implemented on biological specimens.</p>","PeriodicalId":520289,"journal":{"name":"Sovremennye tekhnologii v meditsine","volume":"18 4","pages":"5-11"},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13602024/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sovremennye tekhnologii v meditsine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17691/stm2026.18.4.01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/31 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Spatial fractionation of proton beams is being considered as a new strategy to reduce the probability of side-effects in radiation therapy on the proton therapy complex (PTC) "Prometheus". By collimating the beams to submillimeter dimensions, the dose profile at the target surface consists of alternating high- and low-dose regions. This promotes sparing of normal tissues along the beam path through the activation of various biological mechanisms. The aim of the study was to implement the minibeam method on the PTC "Prometheus" and to experimentally assess the quality of the resulting dose distribution.

Materials and methods: Collimation of the primary beam was achieved using brass multislit collimators. Mathematical modeling of the experiment was performed, and a phantom was irradiated from one and from two opposite directions. For effective summation of two fields and to achieve a homogeneous dose distribution in the target, intensity and energy modulation of the proton beams entering the collimator was carried out. To reduce errors caused by collimator deviation relative to the beam axis, a quality assurance system for collimator positioning on the treatment table was developed. Under the control of a scintillation detector and a laser positioner, positioning accuracy was within 0.2°. GafChromic EBT3 radiochromic films (Ashland, USA) were used as dosimeters.

Results: When comparing calculated and experimental data, 90% of the distribution points matched the mathematical model according to the γ criterion (3%/3 mm). The quality of the minibeam field was assessed using the following parameters: valley-to-peak dose ratio; collimator throughput; ratio of the dose without the collimator to the dose with the collimator; and dose homogeneity index in the target. The obtained results met the quality assurance criteria for standard radiation therapy.

Conclusion: Irradiation with proton minibeams using brass collimators is feasible on the PTC "Prometheus". A uniform dose distribution in the target area was experimentally achieved. The uniformity of coverage, the absence of local dose excesses, and the high dose gradient at the distal edge suggest that the described irradiation technique can be implemented on biological specimens.

质子微束技术在质子治疗复合物“普罗米修斯”上应用的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书