Optimizing 3D FLAIR imaging of endolymphatic hydrops: Benefits and limitations of deep learning reconstruction.

IF 11.1 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Fatma Boubaker, Jeanne Stemart, Gabriela Hossu, Cécile Parietti-Winkler, Dominik Nickel, Pedro Augusto Gondim Teixeira, Alain Blum, Michael Eliezer, Romain Gillet
{"title":"Optimizing 3D FLAIR imaging of endolymphatic hydrops: Benefits and limitations of deep learning reconstruction.","authors":"Fatma Boubaker, Jeanne Stemart, Gabriela Hossu, Cécile Parietti-Winkler, Dominik Nickel, Pedro Augusto Gondim Teixeira, Alain Blum, Michael Eliezer, Romain Gillet","doi":"10.1016/j.diii.2026.09.003","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to evaluate the influence of deep learning reconstruction (DLR) on image quality and diagnostic performance of three-dimensional (3D) fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) of the inner ear.</p><p><strong>Material and methods: </strong>Fifty-three patients (32 women; mean age, 57.4 ± 16.1 [standard deviation (SD)] years) were prospectively included. All patients underwent 3D FLAIR MRI of the inner ear. Four MRI sequences were analyzed, including conventional FLAIR (acquisition time, 7 min 14 s), high-resolution FLAIR (6 min 54 s), DLR-FLAIR (6 min 54 s), and accelerated DLR-FLAIR (5 min 34 s). Signal-to-noise ratio (SNR) was measured for objective analysis. Two readers independently evaluated diagnostic performance using conventional 3D FLAIR images as the standard of reference, and image quality (i.e., motion artifacts, noise, edge sharpness, global quality). Interobserver agreement was assessed using kappa statistics and Bland Altman analysis.</p><p><strong>Results: </strong>DLR significantly increased SNR compared to non-DLR sequences (P < 0.001), with the highest SNR values observed for DLR-FLAIR images (91.2 ± 29.2 [SD]). Subjective analysis showed significant noise reduction and improved global image quality with DLR-FLAIR images (P < 0.001). Sensitivities for the diagnosis of inner-ear findings of the different sequences ranged between 62.5% and 100% and specificities between 92.1% and 100%, with no significant differences between sequences. Interobserver agreement was substantial to almost perfect for most findings but decreased for subtle structures and with the accelerated DLR-FLAIR sequence. Bland Altman analysis showed no systematic bias but increased variability with DLR.</p><p><strong>Conclusion: </strong>DLR significantly improves image quality in 3D FLAIR imaging of the inner ear, without compromising diagnostic performance. However, it may influence interobserver variability, particularly for subtle findings and accelerated acquisitions, which may modify diagnostic behavior, highlighting the importance of adapted interpretation strategies.</p>","PeriodicalId":48656,"journal":{"name":"Diagnostic and Interventional Imaging","volume":" ","pages":""},"PeriodicalIF":11.1000,"publicationDate":"2026-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic and Interventional Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.diii.2026.09.003","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The purpose of this study was to evaluate the influence of deep learning reconstruction (DLR) on image quality and diagnostic performance of three-dimensional (3D) fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) of the inner ear.

Material and methods: Fifty-three patients (32 women; mean age, 57.4 ± 16.1 [standard deviation (SD)] years) were prospectively included. All patients underwent 3D FLAIR MRI of the inner ear. Four MRI sequences were analyzed, including conventional FLAIR (acquisition time, 7 min 14 s), high-resolution FLAIR (6 min 54 s), DLR-FLAIR (6 min 54 s), and accelerated DLR-FLAIR (5 min 34 s). Signal-to-noise ratio (SNR) was measured for objective analysis. Two readers independently evaluated diagnostic performance using conventional 3D FLAIR images as the standard of reference, and image quality (i.e., motion artifacts, noise, edge sharpness, global quality). Interobserver agreement was assessed using kappa statistics and Bland Altman analysis.

Results: DLR significantly increased SNR compared to non-DLR sequences (P < 0.001), with the highest SNR values observed for DLR-FLAIR images (91.2 ± 29.2 [SD]). Subjective analysis showed significant noise reduction and improved global image quality with DLR-FLAIR images (P < 0.001). Sensitivities for the diagnosis of inner-ear findings of the different sequences ranged between 62.5% and 100% and specificities between 92.1% and 100%, with no significant differences between sequences. Interobserver agreement was substantial to almost perfect for most findings but decreased for subtle structures and with the accelerated DLR-FLAIR sequence. Bland Altman analysis showed no systematic bias but increased variability with DLR.

Conclusion: DLR significantly improves image quality in 3D FLAIR imaging of the inner ear, without compromising diagnostic performance. However, it may influence interobserver variability, particularly for subtle findings and accelerated acquisitions, which may modify diagnostic behavior, highlighting the importance of adapted interpretation strategies.

优化内淋巴积液的3D FLAIR成像:深度学习重建的优点和局限性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Diagnostic and Interventional Imaging
Diagnostic and Interventional Imaging Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
8.50
自引率
29.10%
发文量
126
审稿时长
11 days
期刊介绍: Diagnostic and Interventional Imaging accepts publications originating from any part of the world based only on their scientific merit. The Journal focuses on illustrated articles with great iconographic topics and aims at aiding sharpening clinical decision-making skills as well as following high research topics. All articles are published in English. Diagnostic and Interventional Imaging publishes editorials, technical notes, letters, original and review articles on abdominal, breast, cancer, cardiac, emergency, forensic medicine, head and neck, musculoskeletal, gastrointestinal, genitourinary, interventional, obstetric, pediatric, thoracic and vascular imaging, neuroradiology, nuclear medicine, as well as contrast material, computer developments, health policies and practice, and medical physics relevant to imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书