Electric-Field-Assisted Enrichment and Electrochemical Detection of Gram-Positive Bacteria Using an FEM-Guided Interdigitated Electrode Biosensor.

IF 6.2 3区 工程技术 Q1 CHEMISTRY, ANALYTICAL
Zeeshan, Naeem Iqbal, Jaeyoung Choi
{"title":"Electric-Field-Assisted Enrichment and Electrochemical Detection of Gram-Positive Bacteria Using an FEM-Guided Interdigitated Electrode Biosensor.","authors":"Zeeshan, Naeem Iqbal, Jaeyoung Choi","doi":"10.3390/bios16090527","DOIUrl":null,"url":null,"abstract":"<p><p>Dielectrophoretic (DEP) enrichment is a powerful strategy to enhance bacterial capture efficiency and accelerate the response of electrochemical biosensors by actively concentrating target bioparticles at the sensing interface. In this study, a combined numerical-experimental framework is developed to rationally design a DEP-assisted electrochemical biosensor with improved bacterial capture and detection performance. A finite-element modeling (FEM) approach was used to model the coupled electric field, dielectrophoretic force, and particle-transport phenomena, providing a quantitative basis for comparing bacterial trapping efficiency across different interdigitated electrode geometries. The modeling reveals that a wave-shaped interdigitated electrode (W_IDE) generates extended high-field regions and an enlarged effective capture area, resulting in an improved bacterial capture efficiency of 19% compared to 12% for the conventional rectangular interdigitated electrodes (R_IDE) under positive DEP (pDEP) conditions. Based on these insights, the W_IDE was fabricated on a printed circuit board (PCB) substrate, modified with platinum-black (Pt-black) to increase electroactive surface area, and interfaced with a custom-built 16-channel portable potentiostat unit, enabling sequential impedance measurements. The developed biosensor was applied to pDEP-assisted impedance detection of <i>Staphylococcus aureus</i> and <i>Micrococcus luteus</i> using vancomycin as the capture probe. The pDEP-assisted operation enabled rapid and highly sensitive detection down to 10 CFU/mL within 30 min with a wide linear range (10-10<sup>5</sup> CFU/mL) in 0.1× PBS, outperforming passive detection (10<sup>2</sup>-10<sup>5</sup> CFU/mL) for both <i>Staphylococcus aureus</i> and <i>Micrococcus luteus</i>. In skim milk, however, the linear detection ranges shifted to 10<sup>2</sup>-10<sup>5</sup> CFU/mL with pDEP-assisted detection and 10<sup>3</sup>-10<sup>5</sup> CFU/mL under passive detection conditions. Overall, this work highlights the significance of combining FEM-optimized electrodes with DEP-driven enrichment to achieve improved bacterial capture, sensitivity, and robustness in electrochemical biosensors.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"16 9","pages":""},"PeriodicalIF":6.2000,"publicationDate":"2026-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13604522/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios16090527","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Dielectrophoretic (DEP) enrichment is a powerful strategy to enhance bacterial capture efficiency and accelerate the response of electrochemical biosensors by actively concentrating target bioparticles at the sensing interface. In this study, a combined numerical-experimental framework is developed to rationally design a DEP-assisted electrochemical biosensor with improved bacterial capture and detection performance. A finite-element modeling (FEM) approach was used to model the coupled electric field, dielectrophoretic force, and particle-transport phenomena, providing a quantitative basis for comparing bacterial trapping efficiency across different interdigitated electrode geometries. The modeling reveals that a wave-shaped interdigitated electrode (W_IDE) generates extended high-field regions and an enlarged effective capture area, resulting in an improved bacterial capture efficiency of 19% compared to 12% for the conventional rectangular interdigitated electrodes (R_IDE) under positive DEP (pDEP) conditions. Based on these insights, the W_IDE was fabricated on a printed circuit board (PCB) substrate, modified with platinum-black (Pt-black) to increase electroactive surface area, and interfaced with a custom-built 16-channel portable potentiostat unit, enabling sequential impedance measurements. The developed biosensor was applied to pDEP-assisted impedance detection of Staphylococcus aureus and Micrococcus luteus using vancomycin as the capture probe. The pDEP-assisted operation enabled rapid and highly sensitive detection down to 10 CFU/mL within 30 min with a wide linear range (10-105 CFU/mL) in 0.1× PBS, outperforming passive detection (102-105 CFU/mL) for both Staphylococcus aureus and Micrococcus luteus. In skim milk, however, the linear detection ranges shifted to 102-105 CFU/mL with pDEP-assisted detection and 103-105 CFU/mL under passive detection conditions. Overall, this work highlights the significance of combining FEM-optimized electrodes with DEP-driven enrichment to achieve improved bacterial capture, sensitivity, and robustness in electrochemical biosensors.

电场辅助富集和利用fem引导的交叉指状电极生物传感器检测革兰氏阳性菌。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biosensors-Basel
Biosensors-Basel Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍: Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书