Valeria Ferraro, Loris Pinto, Liang Li, Federico Baruzzi, Dmitri B Papkovsky, Elisa Santovito
{"title":"Rapid Bacterial Detection on Surfaces by Field-Deployable Respirometric Sensor Sachets.","authors":"Valeria Ferraro, Loris Pinto, Liang Li, Federico Baruzzi, Dmitri B Papkovsky, Elisa Santovito","doi":"10.3390/bios16090503","DOIUrl":null,"url":null,"abstract":"<p><p>Monitoring bacterial contamination on surfaces is critical for hygiene and safety assurance in food, healthcare, and pharmaceutical settings, although routine methods still remain slow and laboratory dependent. Here, we report a portable respirometric platform based on sealed sensor sachets incorporating optical oxygen sensors to rapidly detect and quantify total aerobic viable counts (TVC) from swabbed surfaces. Following standardized surface swabbing, samples were incubated in the sachets and oxygen depletion kinetics were recorded with a handheld reader and microbial activity was inferred from oxygen consumption. Reference quantification was obtained by serial dilution and aerobic plate counting, enabling direct benchmarking of the respirometric readout against an industry-accepted culture method such as ISO 4833:2013. The platform demonstrated strong agreement with plate counts (R<sup>2</sup> > 0.94), achieving a median detection limit of 2.69 log<sub>10</sub> CFU/cm<sup>2</sup> and a dynamic range of 0-6 log<sub>10</sub> CFU/cm<sup>2</sup> for surface-associated microbial loads. The sensor system was also applied in a semi-industrial setting in a meat processing plant. Across replicate measurements, the assay provided consistent kinetic signatures and quantitative outputs, suitable for rapid and practical decision-making. Compared with traditional culture-based approaches (requiring up to 72 h), the respirometric sachets delivered actionable results within 10 h using a portable, low-infrastructure workflow, supporting rapid on-site hygiene verification and sanitation control.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"16 9","pages":""},"PeriodicalIF":6.2000,"publicationDate":"2026-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13604147/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios16090503","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Monitoring bacterial contamination on surfaces is critical for hygiene and safety assurance in food, healthcare, and pharmaceutical settings, although routine methods still remain slow and laboratory dependent. Here, we report a portable respirometric platform based on sealed sensor sachets incorporating optical oxygen sensors to rapidly detect and quantify total aerobic viable counts (TVC) from swabbed surfaces. Following standardized surface swabbing, samples were incubated in the sachets and oxygen depletion kinetics were recorded with a handheld reader and microbial activity was inferred from oxygen consumption. Reference quantification was obtained by serial dilution and aerobic plate counting, enabling direct benchmarking of the respirometric readout against an industry-accepted culture method such as ISO 4833:2013. The platform demonstrated strong agreement with plate counts (R2 > 0.94), achieving a median detection limit of 2.69 log10 CFU/cm2 and a dynamic range of 0-6 log10 CFU/cm2 for surface-associated microbial loads. The sensor system was also applied in a semi-industrial setting in a meat processing plant. Across replicate measurements, the assay provided consistent kinetic signatures and quantitative outputs, suitable for rapid and practical decision-making. Compared with traditional culture-based approaches (requiring up to 72 h), the respirometric sachets delivered actionable results within 10 h using a portable, low-infrastructure workflow, supporting rapid on-site hygiene verification and sanitation control.
Biosensors-BaselBiochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍:
Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.