{"title":"Periodontal Disease Diagnosis by a Chemically Etched Single-Mode Fiber-Optic Biosensor for Label-Free Detection of Matrix Metalloproteinase-8 (MMP-8).","authors":"Rigoberto Tovar, Sarkis Sozkes, Marzhan Sypabekova","doi":"10.3390/bios16090491","DOIUrl":null,"url":null,"abstract":"<p><p>A miniature label-free biosensor based on a chemically etched single-mode optical fiber (SMF) is reported for the detection of matrix metalloproteinase-8 (MMP-8), a salivary biomarker of active periodontitis with a clinical decision threshold of 20 ng/mL. Fibers etched in 48% hydrofluoric acid to a waist diameter of 16.0 ± 1.4 µm gave a mean refractive index (RI) sensitivity of 376.8%/RIU and an RI limit of detection (LOD) of 5.9 × 10<sup>-4</sup> RIU. Fibers were tested with MMP-8 spiked into phosphate-buffered saline (PBS) and into saliva over 0-200 ng/mL using a post-rinse protocol with per-fiber matrix subtraction. Dose-responses followed a Langmuir isotherm (Kd = 7.1 ng/mL in PBS, 12.7 ng/mL in saliva), with cohort LODs of 0.043 and 0.52 ng/mL, both well below the threshold. MMP-9 (100 ng/mL) and human serum albumin (1 mg/mL) gave negligible responses (≤2.7%, versus 68.2% for MMP-8 at 100 ng/mL); antibody immobilization was confirmed by confocal immunofluorescence. A commercial sandwich ELISA on the same spike series gave a matched-matrix LOD of 41.1 ng/mL, nearly two orders of magnitude higher. This performance requires no metal coating, nanostructuring, label, or signal amplification, only a single wet-etching step on stock telecommunications fiber.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"16 9","pages":""},"PeriodicalIF":6.2000,"publicationDate":"2026-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13604195/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios16090491","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
A miniature label-free biosensor based on a chemically etched single-mode optical fiber (SMF) is reported for the detection of matrix metalloproteinase-8 (MMP-8), a salivary biomarker of active periodontitis with a clinical decision threshold of 20 ng/mL. Fibers etched in 48% hydrofluoric acid to a waist diameter of 16.0 ± 1.4 µm gave a mean refractive index (RI) sensitivity of 376.8%/RIU and an RI limit of detection (LOD) of 5.9 × 10-4 RIU. Fibers were tested with MMP-8 spiked into phosphate-buffered saline (PBS) and into saliva over 0-200 ng/mL using a post-rinse protocol with per-fiber matrix subtraction. Dose-responses followed a Langmuir isotherm (Kd = 7.1 ng/mL in PBS, 12.7 ng/mL in saliva), with cohort LODs of 0.043 and 0.52 ng/mL, both well below the threshold. MMP-9 (100 ng/mL) and human serum albumin (1 mg/mL) gave negligible responses (≤2.7%, versus 68.2% for MMP-8 at 100 ng/mL); antibody immobilization was confirmed by confocal immunofluorescence. A commercial sandwich ELISA on the same spike series gave a matched-matrix LOD of 41.1 ng/mL, nearly two orders of magnitude higher. This performance requires no metal coating, nanostructuring, label, or signal amplification, only a single wet-etching step on stock telecommunications fiber.
Biosensors-BaselBiochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍:
Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.