Tailoring Polyetherimide Ultrafiltration Membranes via Non-Solvent- and Vapor-Induced Phase Separation: Effects of Fabrication Pathway and Membrane Formulation on Morphology and Bovine Serum Albumin Separation Performance.

IF 4.2 4区 工程技术 Q2 CHEMISTRY, PHYSICAL
Mohammad Hosein Moghadasin, Masoud Salavati, Mohammed Majdoub, Ahmed Al-Ostaz, Alexander M Lopez, Sasan Nouranian
{"title":"Tailoring Polyetherimide Ultrafiltration Membranes via Non-Solvent- and Vapor-Induced Phase Separation: Effects of Fabrication Pathway and Membrane Formulation on Morphology and Bovine Serum Albumin Separation Performance.","authors":"Mohammad Hosein Moghadasin, Masoud Salavati, Mohammed Majdoub, Ahmed Al-Ostaz, Alexander M Lopez, Sasan Nouranian","doi":"10.3390/membranes16090288","DOIUrl":null,"url":null,"abstract":"<p><p>Polyetherimide (PEI) ultrafiltration membranes were fabricated for bovine serum albumin (BSA) separation using nonsolvent-induced phase separation (NIPS) and vapor-induced phase separation (VIPS). In the NIPS approach, membranes containing varying amounts of Pluronic P-123, with or without graphene nanoplatelets (GNPs), were prepared. Pluronic P-123 acted as a pore-forming agent, while GNPs enhanced permeability without compromising rejection. The membrane with 1 wt.% Pluronic P-123 achieved a pure water flux (PWF) of 355 LMH and 90% BSA rejection. Incorporating 1 wt.% GNPs further improved performance to 747 LMH and 98% rejection. VIPS membranes were fabricated using the same composition as N10, containing 17 wt.% PEI and 1 wt.% Pluronic P-123 without GNPs, to isolate the effect of the fabrication pathway. Increasing vapor exposure time reduced PWF but generally improved BSA rejection, whereas higher RH increased PWF while decreasing rejection. The composition-matched NIPS membrane, N10, exhibited a PWF of 355 LMH and approximately 91% BSA rejection. In comparison, the highest PWF and BSA rejection among the VIPS membranes were 91 LMH and 76.5%, respectively, and the selected balanced VIPS condition at 30 min and 65% RH yielded approximately 49 LMH and 55% rejection. The higher performance of N11, which achieved 747 LMH and 98% rejection, is attributed to GNP incorporation within the NIPS series and was not used to isolate the fabrication-pathway effect. Overall, the composition-matched comparison demonstrates that NIPS produced a more favorable morphology and BSA separation performance than VIPS under the investigated conditions.</p>","PeriodicalId":18410,"journal":{"name":"Membranes","volume":"16 9","pages":""},"PeriodicalIF":4.2000,"publicationDate":"2026-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13609832/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Membranes","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/membranes16090288","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Polyetherimide (PEI) ultrafiltration membranes were fabricated for bovine serum albumin (BSA) separation using nonsolvent-induced phase separation (NIPS) and vapor-induced phase separation (VIPS). In the NIPS approach, membranes containing varying amounts of Pluronic P-123, with or without graphene nanoplatelets (GNPs), were prepared. Pluronic P-123 acted as a pore-forming agent, while GNPs enhanced permeability without compromising rejection. The membrane with 1 wt.% Pluronic P-123 achieved a pure water flux (PWF) of 355 LMH and 90% BSA rejection. Incorporating 1 wt.% GNPs further improved performance to 747 LMH and 98% rejection. VIPS membranes were fabricated using the same composition as N10, containing 17 wt.% PEI and 1 wt.% Pluronic P-123 without GNPs, to isolate the effect of the fabrication pathway. Increasing vapor exposure time reduced PWF but generally improved BSA rejection, whereas higher RH increased PWF while decreasing rejection. The composition-matched NIPS membrane, N10, exhibited a PWF of 355 LMH and approximately 91% BSA rejection. In comparison, the highest PWF and BSA rejection among the VIPS membranes were 91 LMH and 76.5%, respectively, and the selected balanced VIPS condition at 30 min and 65% RH yielded approximately 49 LMH and 55% rejection. The higher performance of N11, which achieved 747 LMH and 98% rejection, is attributed to GNP incorporation within the NIPS series and was not used to isolate the fabrication-pathway effect. Overall, the composition-matched comparison demonstrates that NIPS produced a more favorable morphology and BSA separation performance than VIPS under the investigated conditions.

通过非溶剂和气相分离裁剪聚醚酰亚胺超滤膜:制备途径和膜配方对形态和牛血清白蛋白分离性能的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Membranes
Membranes Chemical Engineering-Filtration and Separation
CiteScore
6.10
自引率
16.70%
发文量
1071
审稿时长
11 weeks
期刊介绍: Membranes (ISSN 2077-0375) is an international, peer-reviewed open access journal of separation science and technology. It publishes reviews, research articles, communications and technical notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. Full experimental and/or methodical details must be provided.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书