Extremely High Fitting Range and Dangerous Levels Permitted by the Current FDA Guidelines for OTC Hearing Aids and the Need to Consider RECDs.

IF 1.7 Q1 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
King Chung
{"title":"Extremely High Fitting Range and Dangerous Levels Permitted by the Current FDA Guidelines for OTC Hearing Aids and the Need to Consider RECDs.","authors":"King Chung","doi":"10.3390/audiolres16050124","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background/Objective</b>: One of the missions of the United States FDA is \"protecting the public health by ensuring the safety, efficacy, and security of human and veterinary drugs, biological products.\" The current guidelines for OTC hearing aids impose an output limit of 111 dB SPL for linear hearing aids and 117 dB SPL for compression hearing aids when measured using 90 dB SPL pure tones in a 2 cc coupler. This means that the sound pressure level at the ear drum at a frequency would be 111 or 117 dB SPL plus the real-ear-to-coupler difference (RECD) of the 2 cc coupler at the frequency. <b>Methods</b>: The maximum aidable hearing thresholds by hypothetical OTC-compression hearing aids that are compliant with the current FDA guidelines were explored using NAL-NL2 and DSLv5 prescriptive methods. The theoretical maximum permissible overall output levels in the ear canal were also calculated. Additionally, the fitting range of OTC-compression hearing aids with a maximum of 117 dB SPL output level at the ear drum was explored. <b>Results</b>: The current FDA guidelines allow OTC-compression hearing aids to provide sufficient gain and headroom to fit individuals with severe to profound hearing loss. In the presence of a loud wideband signal, the maximum overall output level can reach 164.5 dB SPL in the ear canal for an OTC-compression hearing aid with a bandwidth of 5657 Hz. When the maximum output levels are defined at the ear drum (i.e., the RECD is already considered), however, the fitting range is lowered to moderate hearing loss and the maximum overall output level is lowered by 10 dB. <b>Conclusions</b>: These findings identified potential regulatory vulnerability in the current FDA guidelines and suggest the need to take the measurement coupler and its corresponding RECDs into account when setting the guidelines for OTC hearing aids. Other alternative strategies to prevent potential abuses of the guidelines are also discussed.</p>","PeriodicalId":44133,"journal":{"name":"Audiology Research","volume":"16 5","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2026-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13600033/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/audiolres16050124","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background/Objective: One of the missions of the United States FDA is "protecting the public health by ensuring the safety, efficacy, and security of human and veterinary drugs, biological products." The current guidelines for OTC hearing aids impose an output limit of 111 dB SPL for linear hearing aids and 117 dB SPL for compression hearing aids when measured using 90 dB SPL pure tones in a 2 cc coupler. This means that the sound pressure level at the ear drum at a frequency would be 111 or 117 dB SPL plus the real-ear-to-coupler difference (RECD) of the 2 cc coupler at the frequency. Methods: The maximum aidable hearing thresholds by hypothetical OTC-compression hearing aids that are compliant with the current FDA guidelines were explored using NAL-NL2 and DSLv5 prescriptive methods. The theoretical maximum permissible overall output levels in the ear canal were also calculated. Additionally, the fitting range of OTC-compression hearing aids with a maximum of 117 dB SPL output level at the ear drum was explored. Results: The current FDA guidelines allow OTC-compression hearing aids to provide sufficient gain and headroom to fit individuals with severe to profound hearing loss. In the presence of a loud wideband signal, the maximum overall output level can reach 164.5 dB SPL in the ear canal for an OTC-compression hearing aid with a bandwidth of 5657 Hz. When the maximum output levels are defined at the ear drum (i.e., the RECD is already considered), however, the fitting range is lowered to moderate hearing loss and the maximum overall output level is lowered by 10 dB. Conclusions: These findings identified potential regulatory vulnerability in the current FDA guidelines and suggest the need to take the measurement coupler and its corresponding RECDs into account when setting the guidelines for OTC hearing aids. Other alternative strategies to prevent potential abuses of the guidelines are also discussed.

当前FDA指南允许的OTC助听器的超高拟合范围和危险水平以及考虑recd的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Audiology Research
Audiology Research AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-
CiteScore
2.30
自引率
23.50%
发文量
56
审稿时长
11 weeks
期刊介绍: The mission of Audiology Research is to publish contemporary, ethical, clinically relevant scientific researches related to the basic science and clinical aspects of the auditory and vestibular system and diseases of the ear that can be used by clinicians, scientists and specialists to improve understanding and treatment of patients with audiological and neurotological disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书