{"title":"Deep learning model for simultaneous vertebral level localization and fracture detection on DXA vertebral fracture assessment images","authors":"Sang Wouk Cho, Dongin Moon, Chang Oh Kim, Hyeon Chang Kim, Yumie Rhee, Namki Hong","doi":"10.1016/j.afos.2026.09.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><div>While vertebral fracture assessment (VFA) on dual-energy X-ray absorptiometry (DXA) images is widely used to detect osteoporotic vertebral fractures, existing deep learning approaches typically perform either fracture detection or vertebral localization, not both. We developed VERTE-X L, a deep learning model that simultaneously localizes vertebrae (T7–L5) and detects fractures on DXA VFA images, and evaluated its performance in a community-dwelling older adult cohort.</div></div><div><h3>Methods</h3><div>We used DXA VFA images from 1000 randomly sampled participants (age ≥65 years) in the Korean Urban Rural Elderly (KURE) cohort, split into training (N = 800) and test (N = 200) sets. VERTE-X L employs a DINOv2-L encoder, a localization decoder for per-vertebra coordinate prediction, and a consistent rank logits (CORAL) ordinal regression module for fracture detection. Performance was evaluated at image and vertebra levels and compared with previously reported detection-only models (VERTE-X and VERTE-X model fine-tuned on VFA data) and localization-only models (VerteNet and Multi-Context Hybrid CNN Transformer).</div></div><div><h3>Results</h3><div>On the held-out test set, VERTE-X L achieved an image-level area under the receiver operating characteristic curve (AUROC) of 0.952 (sensitivity 89.7%, specificity 94.2%, net present value [NPV] 98.2%) and vertebra-level AUROC of 0.957 (NPV 99.7%). Localization success (within 15 pixels) was 94.7% for fracture vertebrae. VERTE-X L outperformed VERTE-X in detection (AUROC 0.952 vs 0.913, P = 0.034) and outperformed VerteNet in localization (mean radial error 10.0 vs. 20.3 px, P < 0.001).</div></div><div><h3>Conclusions</h3><div>The proposed method enables simultaneous fracture detection and vertebral localization on DXA VFA images.</div></div>","PeriodicalId":19701,"journal":{"name":"Osteoporosis and Sarcopenia","volume":"12 3","pages":"Pages 16-22"},"PeriodicalIF":2.4000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Osteoporosis and Sarcopenia","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2405525526000531","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
While vertebral fracture assessment (VFA) on dual-energy X-ray absorptiometry (DXA) images is widely used to detect osteoporotic vertebral fractures, existing deep learning approaches typically perform either fracture detection or vertebral localization, not both. We developed VERTE-X L, a deep learning model that simultaneously localizes vertebrae (T7–L5) and detects fractures on DXA VFA images, and evaluated its performance in a community-dwelling older adult cohort.
Methods
We used DXA VFA images from 1000 randomly sampled participants (age ≥65 years) in the Korean Urban Rural Elderly (KURE) cohort, split into training (N = 800) and test (N = 200) sets. VERTE-X L employs a DINOv2-L encoder, a localization decoder for per-vertebra coordinate prediction, and a consistent rank logits (CORAL) ordinal regression module for fracture detection. Performance was evaluated at image and vertebra levels and compared with previously reported detection-only models (VERTE-X and VERTE-X model fine-tuned on VFA data) and localization-only models (VerteNet and Multi-Context Hybrid CNN Transformer).
Results
On the held-out test set, VERTE-X L achieved an image-level area under the receiver operating characteristic curve (AUROC) of 0.952 (sensitivity 89.7%, specificity 94.2%, net present value [NPV] 98.2%) and vertebra-level AUROC of 0.957 (NPV 99.7%). Localization success (within 15 pixels) was 94.7% for fracture vertebrae. VERTE-X L outperformed VERTE-X in detection (AUROC 0.952 vs 0.913, P = 0.034) and outperformed VerteNet in localization (mean radial error 10.0 vs. 20.3 px, P < 0.001).
Conclusions
The proposed method enables simultaneous fracture detection and vertebral localization on DXA VFA images.
Osteoporosis and SarcopeniaOrthopedics, Sports Medicine and Rehabilitation, Endocrinology, Diabetes and Metabolism, Obstetrics, Gynecology and Women's Health, Geriatrics and Gerontology