Terahertz wavelength-division multiplexing sensor based on a multi-channel waveguide leaky-wave antenna

IF 7.1 1区 物理与天体物理 Q1 OPTICS
Fan Yang,Yiming Wang,Ruishu Zuo,Liang Ma,Yunyun Ji,Xianghui Wang,Shengjiang Chang,Fei Fan
{"title":"Terahertz wavelength-division multiplexing sensor based on a multi-channel waveguide leaky-wave antenna","authors":"Fan Yang,Yiming Wang,Ruishu Zuo,Liang Ma,Yunyun Ji,Xianghui Wang,Shengjiang Chang,Fei Fan","doi":"10.1364/prj.591541","DOIUrl":null,"url":null,"abstract":"Although terahertz waveguide sensors have the potential for high sensitivity, their single-channel architecture severely limits detection throughput and multi-parameter parallel analysis capabilities. This paper proposes and implements a terahertz wavelength-division multiplexing sensor based on spatial–spectral mapping, centered on a parallel-plate waveguide leaky-wave antenna integrated with a gradient slit array. By optimizing the waveguide structural parameters, we achieved low crosstalk and frequency tuning for multi-channel signals. The research system verified the sensor’s parallel detection capability and channel independence. When the samples are applied to the slit region of the output plate, the sensor’s individual channels exhibited an intensity modulation sensitivity of 1.2%/(mg/mL) and a frequency sensing sensitivity of 0.57 GHz/(mg/mL). When the sample is placed between the waveguide plates, the sensitivities are 1.6%/(mg/mL) and 0.2 GHz/(mg/mL). Moreover, only the slit channels corresponding to the sample-covered areas showed characteristic frequency shifts, while signals from uncovered channels remained stable, demonstrating the spatial independence of each sensing channel. This work provides practical support for developing the next generation of high-throughput, chip-integrated terahertz sensing systems, which establishes a new pathway toward multi-target analysis and real-time monitoring for biomedical, environmental, and industrial applications.","PeriodicalId":20048,"journal":{"name":"Photonics Research","volume":"90 1","pages":"4252"},"PeriodicalIF":7.1000,"publicationDate":"2026-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photonics Research","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1364/prj.591541","RegionNum":1,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Although terahertz waveguide sensors have the potential for high sensitivity, their single-channel architecture severely limits detection throughput and multi-parameter parallel analysis capabilities. This paper proposes and implements a terahertz wavelength-division multiplexing sensor based on spatial–spectral mapping, centered on a parallel-plate waveguide leaky-wave antenna integrated with a gradient slit array. By optimizing the waveguide structural parameters, we achieved low crosstalk and frequency tuning for multi-channel signals. The research system verified the sensor’s parallel detection capability and channel independence. When the samples are applied to the slit region of the output plate, the sensor’s individual channels exhibited an intensity modulation sensitivity of 1.2%/(mg/mL) and a frequency sensing sensitivity of 0.57 GHz/(mg/mL). When the sample is placed between the waveguide plates, the sensitivities are 1.6%/(mg/mL) and 0.2 GHz/(mg/mL). Moreover, only the slit channels corresponding to the sample-covered areas showed characteristic frequency shifts, while signals from uncovered channels remained stable, demonstrating the spatial independence of each sensing channel. This work provides practical support for developing the next generation of high-throughput, chip-integrated terahertz sensing systems, which establishes a new pathway toward multi-target analysis and real-time monitoring for biomedical, environmental, and industrial applications.
基于多通道波导漏波天线的太赫兹波分复用传感器
虽然太赫兹波导传感器具有高灵敏度的潜力,但其单通道架构严重限制了检测吞吐量和多参数并行分析能力。本文提出并实现了一种基于空间光谱映射的太赫兹波分复用传感器,该传感器以梯度狭缝阵列集成的平行板波导漏波天线为中心。通过优化波导结构参数,实现了多通道信号的低串扰和频率调谐。研究系统验证了传感器的并行检测能力和信道独立性。当样品施加到输出板的狭缝区域时,传感器各通道的强度调制灵敏度为1.2%/(mg/mL),频率传感灵敏度为0.57 GHz/(mg/mL)。当样品放置在波导板之间时,灵敏度分别为1.6%/(mg/mL)和0.2 GHz/(mg/mL)。此外,只有样品覆盖区域对应的狭缝通道出现特征频移,而未覆盖通道的信号保持稳定,表明每个传感通道的空间独立性。这项工作为开发下一代高通量、芯片集成的太赫兹传感系统提供了实际支持,为生物医学、环境和工业应用建立了多目标分析和实时监测的新途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
13.60
自引率
5.30%
发文量
1325
期刊介绍: Photonics Research is a joint publishing effort of the OSA and Chinese Laser Press.It publishes fundamental and applied research progress in optics and photonics. Topics include, but are not limited to, lasers, LEDs and other light sources; fiber optics and optical communications; imaging, detectors and sensors; novel materials and engineered structures; optical data storage and displays; plasmonics; quantum optics; diffractive optics and guided optics; medical optics and biophotonics; ultraviolet and x-rays; terahertz technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书