Preoperative Corneal Astigmatic Direction is Associated with Stromal Mechanical Anisotropy in SMILE-Derived Lenticules.

Clinical ophthalmology (Auckland, N.Z.) Pub Date : 2026-09-16 eCollection Date: 2026-01-01 DOI:10.2147/OPTH.S641270
Pengfei Han, Peng Chen, Xiaolong Fang, Hongwei Qin, Yuan Wu, Shuangshuang Chen, Yan Li, Jie Zhang, Qizhi Zhou
{"title":"Preoperative Corneal Astigmatic Direction is Associated with Stromal Mechanical Anisotropy in SMILE-Derived Lenticules.","authors":"Pengfei Han, Peng Chen, Xiaolong Fang, Hongwei Qin, Yuan Wu, Shuangshuang Chen, Yan Li, Jie Zhang, Qizhi Zhou","doi":"10.2147/OPTH.S641270","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Direction-dependent mechanical behavior exists in the human corneal stroma, but fixed-axis biomechanical testing may be influenced by preoperative astigmatic direction. This study evaluated whether corneal astigmatic direction, a routinely measurable clinical phenotype, corresponds to superior-inferior (SI) vs nasal-temporal (NT) mechanical anisotropy in human stromal lenticules obtained during small-incision lenticule extraction (SMILE).</p><p><strong>Patients and methods: </strong>Fifty-three spherical stromal lenticules with a programmed cylinder correction of 0 diopters were prospectively collected. Preoperative anterior corneal astigmatism was classified as with-the-rule (WTR) or against-the-rule (ATR), and the steep-axis information was decomposed into a vertical-horizontal component matched to the SI-NT mechanical testing coordinates. Equibiaxial testing was performed along the SI and NT axes, and tangent moduli were calculated at 0.03 MPa. The signed meridional difference index (MDI) was defined as E<sub>SI</sub> - E<sub>NT</sub>.</p><p><strong>Results: </strong>WTR lenticules predominantly showed higher SI modulus, whereas ATR lenticules predominantly showed higher NT modulus. The vertical-horizontal astigmatic component was strongly correlated with signed MDI (Spearman rho = 0.875, P < 0.001), and this association remained significant after multivariable adjustment (β = 0.673 MPa/diopter, 95% CI 0.537-0.809, P < 0.001). Corneal astigmatism magnitude was also associated with direction-independent anisotropy magnitude.</p><p><strong>Conclusion: </strong>Preoperative corneal astigmatic direction may be a clinically measurable stratification variable for interpreting fixed-axis stromal mechanical anisotropy measurements in SMILE-derived lenticules. These findings support incorporating directional clinical phenotypes into corneal biomechanical research and patient-specific modeling, while requiring validation in larger independent samples.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":"20 ","pages":"641270"},"PeriodicalIF":0.0000,"publicationDate":"2026-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13590252/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S641270","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Direction-dependent mechanical behavior exists in the human corneal stroma, but fixed-axis biomechanical testing may be influenced by preoperative astigmatic direction. This study evaluated whether corneal astigmatic direction, a routinely measurable clinical phenotype, corresponds to superior-inferior (SI) vs nasal-temporal (NT) mechanical anisotropy in human stromal lenticules obtained during small-incision lenticule extraction (SMILE).

Patients and methods: Fifty-three spherical stromal lenticules with a programmed cylinder correction of 0 diopters were prospectively collected. Preoperative anterior corneal astigmatism was classified as with-the-rule (WTR) or against-the-rule (ATR), and the steep-axis information was decomposed into a vertical-horizontal component matched to the SI-NT mechanical testing coordinates. Equibiaxial testing was performed along the SI and NT axes, and tangent moduli were calculated at 0.03 MPa. The signed meridional difference index (MDI) was defined as ESI - ENT.

Results: WTR lenticules predominantly showed higher SI modulus, whereas ATR lenticules predominantly showed higher NT modulus. The vertical-horizontal astigmatic component was strongly correlated with signed MDI (Spearman rho = 0.875, P < 0.001), and this association remained significant after multivariable adjustment (β = 0.673 MPa/diopter, 95% CI 0.537-0.809, P < 0.001). Corneal astigmatism magnitude was also associated with direction-independent anisotropy magnitude.

Conclusion: Preoperative corneal astigmatic direction may be a clinically measurable stratification variable for interpreting fixed-axis stromal mechanical anisotropy measurements in SMILE-derived lenticules. These findings support incorporating directional clinical phenotypes into corneal biomechanical research and patient-specific modeling, while requiring validation in larger independent samples.

术前角膜散光方向与smile衍生晶状体间质力学各向异性有关。
目的:人角膜基质存在方向依赖的力学行为,但固定轴生物力学测试可能受到术前散光方向的影响。本研究评估了角膜散光方向,一种常规可测量的临床表型,是否对应于小切口晶状体提取(SMILE)中获得的人间质晶状体的上下(SI)和鼻颞(NT)力学各向异性。患者和方法:前瞻性收集了53个经程序校正为0屈光度的球形间质透镜。将术前角膜前散光分为顺规则(WTR)和反规则(ATR),并将陡轴信息分解为与SI-NT力学测试坐标匹配的垂直水平分量。沿SI轴和NT轴进行等双轴试验,在0.03 MPa下计算切线模量。符号经向差指数(MDI)定义为ESI - ENT。结果:WTR微孔主要表现出较高的SI模量,而ATR微孔主要表现出较高的NT模量。垂直-水平散光分量与有符号MDI密切相关(Spearman ρ = 0.875, P < 0.001),多变量校正后这种相关性仍然显著(β = 0.673 MPa/diopter, 95% CI 0.537 ~ 0.809, P < 0.001)。角膜散光大小也与方向无关的各向异性大小有关。结论:术前角膜散光方向可能是临床上可测量的分层变量,用于解释smile衍生透镜体的固定轴间质力学各向异性测量。这些发现支持将定向临床表型纳入角膜生物力学研究和患者特异性建模,但需要在更大的独立样本中进行验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书