Pediatric Chest Photon-counting CT: Dose and Noise Behavior of Clinical Sn100 kVp and 90 kVp Protocols across Image Quality Levels - a Phantom Study.

IF 2 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Laura Valentina Klüner, Sebastian Zensen, Hannah Peuster, Melanie Ebenau, Denise Bos, Raya Ocker-Serger, Yannick Laurent Thal, Luca Salhöfer, Florian Stehling, Daniel Bernard, Erik Büscher, Matthias Welsner, Lale Umutlu, Michael Forsting, Johannes Haubold, Marcel Klaus Opitz
{"title":"Pediatric Chest Photon-counting CT: Dose and Noise Behavior of Clinical Sn100 kVp and 90 kVp Protocols across Image Quality Levels - a Phantom Study.","authors":"Laura Valentina Klüner, Sebastian Zensen, Hannah Peuster, Melanie Ebenau, Denise Bos, Raya Ocker-Serger, Yannick Laurent Thal, Luca Salhöfer, Florian Stehling, Daniel Bernard, Erik Büscher, Matthias Welsner, Lale Umutlu, Michael Forsting, Johannes Haubold, Marcel Klaus Opitz","doi":"10.1055/a-2935-4084","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Photon-counting CT (PCCT) and spectral shaping enable new approaches in pediatric imaging, but the effects of clinically implemented tin-filtered pediatric chest protocols on radiation dose and image noise across image quality levels (IQLs) remain insufficiently characterized. This study compared a clinical Sn100 kVp ultra-high resolution (UHR) protocol with a non-tin-filtered 90 kVp standard-resolution protocol using anthropomorphic pediatric phantoms.</p><p><strong>Materials and methods: </strong>Three pediatric phantoms (1, 5, and 10 years) were scanned on a commercial PCCT system across IQLs 1-300 using the clinical Sn100 kVp UHR and non-tin-filtered 90 kVp standard-resolution protocols. Radiation dose and ROI-based image noise in lung parenchyma and bone were recorded.</p><p><strong>Results: </strong>The Sn100 kVp UHR protocol showed lower lung-parenchymal noise across all phantom sizes and IQLs and generally lower bone noise. In the ultra-low-dose range (IQL 1-10), lung-parenchymal noise reductions ranged from 31% to 52% and bone-noise reductions reached 58%. Across most IQLs, the Sn100 kVp UHR protocol was associated with higher radiation dose. At high IQLs, dose plateaus occurred at approximately IQL 150 and 100 in the 5- and 10-year-old phantoms, followed by dose crossovers at approximately IQL 220 and 150, respectively. At very low IQLs, the Sn100 kVp UHR protocol showed a dose advantage up to IQL 5, 4, and 3 in the 1-, 5-, and 10-year-old phantoms, respectively.</p><p><strong>Conclusions: </strong>The Sn100 kVp UHR protocol was associated with lower image noise but was not universally dose-saving compared with the non-tin-filtered 90 kVp standard-resolution protocol. In addition, the observed dose behavior was influenced not only by spectral shaping but also by detector readout mode and protocol-specific technical constraints. These findings may support future pediatric chest PCCT protocol optimization.</p><p><strong>Key points: </strong>· The clinical Sn100 kVp UHR protocol was associated with lower lung-parenchymal noise and generally lower bone noise compared with the non-tin-filtered 90 kVp standard-resolution protocol.. · The dose advantage of the Sn100 kVp UHR protocol was limited to very low IQLs, while most IQLs showed higher radiation dose compared with the 90 kVp standard-resolution protocol.. · At high image quality levels, the Sn100 kVp UHR protocol exhibited dose plateaus, limiting further dose increase despite higher target image quality..</p><p><strong>Citation format: </strong>· Klüner LV, Zensen S, Peuster H et al. Pediatric Chest Photon-counting CT: Dose and Noise Behavior of Clinical Sn100 kVp and 90 kVp Protocols across Image Quality Levels - a Phantom Study. Rofo 2026; DOI 10.1055/a-2935-4084.</p>","PeriodicalId":21490,"journal":{"name":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2026-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2935-4084","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Photon-counting CT (PCCT) and spectral shaping enable new approaches in pediatric imaging, but the effects of clinically implemented tin-filtered pediatric chest protocols on radiation dose and image noise across image quality levels (IQLs) remain insufficiently characterized. This study compared a clinical Sn100 kVp ultra-high resolution (UHR) protocol with a non-tin-filtered 90 kVp standard-resolution protocol using anthropomorphic pediatric phantoms.

Materials and methods: Three pediatric phantoms (1, 5, and 10 years) were scanned on a commercial PCCT system across IQLs 1-300 using the clinical Sn100 kVp UHR and non-tin-filtered 90 kVp standard-resolution protocols. Radiation dose and ROI-based image noise in lung parenchyma and bone were recorded.

Results: The Sn100 kVp UHR protocol showed lower lung-parenchymal noise across all phantom sizes and IQLs and generally lower bone noise. In the ultra-low-dose range (IQL 1-10), lung-parenchymal noise reductions ranged from 31% to 52% and bone-noise reductions reached 58%. Across most IQLs, the Sn100 kVp UHR protocol was associated with higher radiation dose. At high IQLs, dose plateaus occurred at approximately IQL 150 and 100 in the 5- and 10-year-old phantoms, followed by dose crossovers at approximately IQL 220 and 150, respectively. At very low IQLs, the Sn100 kVp UHR protocol showed a dose advantage up to IQL 5, 4, and 3 in the 1-, 5-, and 10-year-old phantoms, respectively.

Conclusions: The Sn100 kVp UHR protocol was associated with lower image noise but was not universally dose-saving compared with the non-tin-filtered 90 kVp standard-resolution protocol. In addition, the observed dose behavior was influenced not only by spectral shaping but also by detector readout mode and protocol-specific technical constraints. These findings may support future pediatric chest PCCT protocol optimization.

Key points: · The clinical Sn100 kVp UHR protocol was associated with lower lung-parenchymal noise and generally lower bone noise compared with the non-tin-filtered 90 kVp standard-resolution protocol.. · The dose advantage of the Sn100 kVp UHR protocol was limited to very low IQLs, while most IQLs showed higher radiation dose compared with the 90 kVp standard-resolution protocol.. · At high image quality levels, the Sn100 kVp UHR protocol exhibited dose plateaus, limiting further dose increase despite higher target image quality..

Citation format: · Klüner LV, Zensen S, Peuster H et al. Pediatric Chest Photon-counting CT: Dose and Noise Behavior of Clinical Sn100 kVp and 90 kVp Protocols across Image Quality Levels - a Phantom Study. Rofo 2026; DOI 10.1055/a-2935-4084.

儿童胸部光子计数CT:临床Sn100 kVp和90 kVp方案跨图像质量水平的剂量和噪声行为-一项幻影研究
目的:光子计数CT (PCCT)和光谱整形为儿科成像提供了新的方法,但临床实施的锡过滤儿科胸部方案对辐射剂量和图像质量水平(iql)图像噪声的影响仍然没有充分表征。本研究比较了临床Sn100 kVp超高分辨率(UHR)方案与非锡过滤的90 kVp标准分辨率方案,使用拟人化儿童模型。材料和方法:使用临床Sn100 kVp UHR和非锡过滤的90 kVp标准分辨率方案,在商用PCCT系统上扫描3名儿童(1岁、5岁和10岁),IQLs为1-300。记录肺实质和骨的辐射剂量和基于roi的图像噪声。结果:Sn100 kVp UHR方案在所有幻象大小和iql中显示较低的肺实质噪声,并且通常较低的骨噪声。在超低剂量范围内(IQL 1-10),肺实质噪声降低31% - 52%,骨噪声降低58%。在大多数iql中,Sn100 kVp UHR方案与较高的辐射剂量相关。在高IQL时,5岁和10岁的幽灵在IQL约150和100处出现剂量平台,随后分别在IQL约220和150处出现剂量交叉。在非常低的IQL下,Sn100 kVp UHR方案在1岁、5岁和10岁的模型中分别显示出高达IQL 5、4和3的剂量优势。结论:Sn100 kVp UHR方案与较低的图像噪声相关,但与非锡过滤的90 kVp标准分辨率方案相比,并非普遍节省剂量。此外,观察到的剂量行为不仅受到光谱整形的影响,还受到检测器读出模式和特定协议的技术限制的影响。这些发现可能支持未来儿科胸部PCCT方案的优化。·与非锡过滤的90 kVp标准分辨率方案相比,临床Sn100 kVp UHR方案具有更低的肺实质噪声和更低的骨噪声。·Sn100 kVp UHR方案的剂量优势仅限于非常低的iql,而大多数iql与90 kVp标准分辨率方案相比显示更高的辐射剂量。·在高图像质量水平下,Sn100 kVp UHR方案呈现剂量平台期,限制了剂量的进一步增加,尽管目标图像质量更高。儿童胸部光子计数CT:临床Sn100 kVp和90 kVp方案跨图像质量水平的剂量和噪声行为-一项幻影研究Rofo 2026;DOI 10.1055 / - 2935 - 4084。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.20
自引率
5.60%
发文量
340
期刊介绍: Die RöFo veröffentlicht Originalarbeiten, Übersichtsartikel und Fallberichte aus dem Bereich der Radiologie und den weiteren bildgebenden Verfahren in der Medizin. Es dürfen nur Arbeiten eingereicht werden, die noch nicht veröffentlicht sind und die auch nicht gleichzeitig einer anderen Zeitschrift zur Veröffentlichung angeboten wurden. Alle eingereichten Beiträge unterliegen einer sorgfältigen fachlichen Begutachtung. Gegründet 1896 – nur knapp 1 Jahr nach der Entdeckung der Röntgenstrahlen durch C.W. Röntgen – blickt die RöFo auf über 100 Jahre Erfahrung als wichtigstes Publikationsmedium in der deutschsprachigen Radiologie zurück. Sie ist damit die älteste radiologische Fachzeitschrift und schafft es erfolgreich, lange Kontinuität mit dem Anspruch an wissenschaftliches Publizieren auf internationalem Niveau zu verbinden. Durch ihren zentralen Platz im Verlagsprogramm stellte die RöFo die Basis für das heute umfassende und erfolgreiche Radiologie-Medienangebot im Georg Thieme Verlag. Besonders eng verbunden ist die RöFo mit der Geschichte der Röntgengesellschaften in Deutschland und Österreich. Sie ist offizielles Organ von DRG und ÖRG und die Mitglieder der Fachgesellschaften erhalten die Zeitschrift im Rahmen ihrer Mitgliedschaft. Mit ihrem wissenschaftlichen Kernteil und dem eigenen Mitteilungsteil der Fachgesellschaften bietet die RöFo Monat für Monat ein Forum für den Austausch von Inhalten und Botschaften der radiologischen Community im deutschsprachigen Raum.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书