{"title":"Motion Capture of Bronchoscopist Kinematics Using a Spatial Computing Device: A Methodological Proof-of-Concept Study.","authors":"Shotaro Okachi, Tomoya Horiguchi, Yasuhiro Goto, Michitaka Fujiwara, Kazuyoshi Imaizumi, Naozumi Hashimoto","doi":"10.1159/res/aepag014","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Bronchoscopy is physically demanding, and studies of ergonomics and objective skill assessment require accurate, segment-resolved capture of the bronchoscopist's hand and head movements. However, existing motion capture approaches typically rely on specialized laboratory infrastructure or wearable sensor arrays, limiting their routine use.</p><p><strong>Methods: </strong>A board-certified pulmonologist performed 10 systematic bronchoscopies across the 18 named segments using an airway simulator and a single-use bronchoscope. Procedures alternated between conditions without and with engagement of the bronchoscope's insertion-tube rotation mechanism. A custom visionOS application running on Apple Vision Pro captured bilateral hand and head poses at 30 Hz, with synchronized voice-cue annotations for each segment.</p><p><strong>Results: </strong>All 180 expected segment insertions were recorded (94.4% via voice cues; 5.6% recovered through tracking-derived hold detection and excluded from per-insertion analyses). Intermittent tracking-freezing artifacts, in which a static pose was retained under a valid tracking flag, were detected by frame-to-frame immobility and excluded from the affected analyses. The mean per-insertion peak left-wrist rotation across all segments was 107.9° without and 72.6° with the rotation mechanism. The mean left-thumb path length within the wrist's local reference frame was 3.82 ± 0.48 m per bronchoscopy, and the estimated number of bronchoscope lever operation cycles was 64.8 ± 7.9 per procedure.</p><p><strong>Conclusion: </strong>In this proof-of-concept study, a single off-the-shelf head-mounted device enabled multichannel capture of bronchoscopist kinematics during simulated bronchoscopy. This approach provides a practical methodological foundation for future studies on bronchoscopy ergonomics, skill assessment, and AI-driven training data generation.</p>","PeriodicalId":21048,"journal":{"name":"Respiration","volume":" ","pages":"1"},"PeriodicalIF":2.6000,"publicationDate":"2026-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respiration","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/res/aepag014","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Bronchoscopy is physically demanding, and studies of ergonomics and objective skill assessment require accurate, segment-resolved capture of the bronchoscopist's hand and head movements. However, existing motion capture approaches typically rely on specialized laboratory infrastructure or wearable sensor arrays, limiting their routine use.
Methods: A board-certified pulmonologist performed 10 systematic bronchoscopies across the 18 named segments using an airway simulator and a single-use bronchoscope. Procedures alternated between conditions without and with engagement of the bronchoscope's insertion-tube rotation mechanism. A custom visionOS application running on Apple Vision Pro captured bilateral hand and head poses at 30 Hz, with synchronized voice-cue annotations for each segment.
Results: All 180 expected segment insertions were recorded (94.4% via voice cues; 5.6% recovered through tracking-derived hold detection and excluded from per-insertion analyses). Intermittent tracking-freezing artifacts, in which a static pose was retained under a valid tracking flag, were detected by frame-to-frame immobility and excluded from the affected analyses. The mean per-insertion peak left-wrist rotation across all segments was 107.9° without and 72.6° with the rotation mechanism. The mean left-thumb path length within the wrist's local reference frame was 3.82 ± 0.48 m per bronchoscopy, and the estimated number of bronchoscope lever operation cycles was 64.8 ± 7.9 per procedure.
Conclusion: In this proof-of-concept study, a single off-the-shelf head-mounted device enabled multichannel capture of bronchoscopist kinematics during simulated bronchoscopy. This approach provides a practical methodological foundation for future studies on bronchoscopy ergonomics, skill assessment, and AI-driven training data generation.
期刊介绍:
''Respiration'' brings together the results of both clinical and experimental investigations on all aspects of the respiratory system in health and disease. Clinical improvements in the diagnosis and treatment of chest and lung diseases are covered, as are the latest findings in physiology, biochemistry, pathology, immunology and pharmacology. The journal includes classic features such as editorials that accompany original articles in clinical and basic science research, reviews and letters to the editor. Further sections are: Technical Notes, The Eye Catcher, What’s Your Diagnosis?, The Opinion Corner, New Drugs in Respiratory Medicine, New Insights from Clinical Practice and Guidelines. ''Respiration'' is the official journal of the Swiss Society for Pneumology (SGP) and also home to the European Association for Bronchology and Interventional Pulmonology (EABIP), which occupies a dedicated section on Interventional Pulmonology in the journal. This modern mix of different features and a stringent peer-review process by a dedicated editorial board make ''Respiration'' a complete guide to progress in thoracic medicine.