Motion Capture of Bronchoscopist Kinematics Using a Spatial Computing Device: A Methodological Proof-of-Concept Study.

IF 2.6 3区 医学 Q2 RESPIRATORY SYSTEM
Respiration Pub Date : 2026-09-21 DOI:10.1159/res/aepag014
Shotaro Okachi, Tomoya Horiguchi, Yasuhiro Goto, Michitaka Fujiwara, Kazuyoshi Imaizumi, Naozumi Hashimoto
{"title":"Motion Capture of Bronchoscopist Kinematics Using a Spatial Computing Device: A Methodological Proof-of-Concept Study.","authors":"Shotaro Okachi, Tomoya Horiguchi, Yasuhiro Goto, Michitaka Fujiwara, Kazuyoshi Imaizumi, Naozumi Hashimoto","doi":"10.1159/res/aepag014","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Bronchoscopy is physically demanding, and studies of ergonomics and objective skill assessment require accurate, segment-resolved capture of the bronchoscopist's hand and head movements. However, existing motion capture approaches typically rely on specialized laboratory infrastructure or wearable sensor arrays, limiting their routine use.</p><p><strong>Methods: </strong>A board-certified pulmonologist performed 10 systematic bronchoscopies across the 18 named segments using an airway simulator and a single-use bronchoscope. Procedures alternated between conditions without and with engagement of the bronchoscope's insertion-tube rotation mechanism. A custom visionOS application running on Apple Vision Pro captured bilateral hand and head poses at 30 Hz, with synchronized voice-cue annotations for each segment.</p><p><strong>Results: </strong>All 180 expected segment insertions were recorded (94.4% via voice cues; 5.6% recovered through tracking-derived hold detection and excluded from per-insertion analyses). Intermittent tracking-freezing artifacts, in which a static pose was retained under a valid tracking flag, were detected by frame-to-frame immobility and excluded from the affected analyses. The mean per-insertion peak left-wrist rotation across all segments was 107.9° without and 72.6° with the rotation mechanism. The mean left-thumb path length within the wrist's local reference frame was 3.82 ± 0.48 m per bronchoscopy, and the estimated number of bronchoscope lever operation cycles was 64.8 ± 7.9 per procedure.</p><p><strong>Conclusion: </strong>In this proof-of-concept study, a single off-the-shelf head-mounted device enabled multichannel capture of bronchoscopist kinematics during simulated bronchoscopy. This approach provides a practical methodological foundation for future studies on bronchoscopy ergonomics, skill assessment, and AI-driven training data generation.</p>","PeriodicalId":21048,"journal":{"name":"Respiration","volume":" ","pages":"1"},"PeriodicalIF":2.6000,"publicationDate":"2026-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respiration","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/res/aepag014","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Bronchoscopy is physically demanding, and studies of ergonomics and objective skill assessment require accurate, segment-resolved capture of the bronchoscopist's hand and head movements. However, existing motion capture approaches typically rely on specialized laboratory infrastructure or wearable sensor arrays, limiting their routine use.

Methods: A board-certified pulmonologist performed 10 systematic bronchoscopies across the 18 named segments using an airway simulator and a single-use bronchoscope. Procedures alternated between conditions without and with engagement of the bronchoscope's insertion-tube rotation mechanism. A custom visionOS application running on Apple Vision Pro captured bilateral hand and head poses at 30 Hz, with synchronized voice-cue annotations for each segment.

Results: All 180 expected segment insertions were recorded (94.4% via voice cues; 5.6% recovered through tracking-derived hold detection and excluded from per-insertion analyses). Intermittent tracking-freezing artifacts, in which a static pose was retained under a valid tracking flag, were detected by frame-to-frame immobility and excluded from the affected analyses. The mean per-insertion peak left-wrist rotation across all segments was 107.9° without and 72.6° with the rotation mechanism. The mean left-thumb path length within the wrist's local reference frame was 3.82 ± 0.48 m per bronchoscopy, and the estimated number of bronchoscope lever operation cycles was 64.8 ± 7.9 per procedure.

Conclusion: In this proof-of-concept study, a single off-the-shelf head-mounted device enabled multichannel capture of bronchoscopist kinematics during simulated bronchoscopy. This approach provides a practical methodological foundation for future studies on bronchoscopy ergonomics, skill assessment, and AI-driven training data generation.

使用空间计算设备的支气管镜检查运动捕捉:一种方法学概念验证研究。
支气管镜检查对身体要求很高,人体工程学和客观技能评估的研究需要准确、分段地捕捉支气管镜检查者的手和头部运动。然而,现有的动作捕捉方法通常依赖于专门的实验室基础设施或可穿戴传感器阵列,限制了它们的常规使用。方法:一名委员会认证的肺科医生使用气道模拟器和一次性支气管镜对18个命名段进行了10次系统支气管镜检查。手术过程在无支气管镜插入-管旋转机制和有支气管镜插入-管旋转机制的情况下交替进行。在Apple Vision Pro上运行的自定义visionOS应用程序以30 Hz的频率捕获了双手和头部的姿势,并为每个片段同步了语音提示注释。结果:所有180个预期的片段插入都被记录下来(94.4%通过语音提示,5.6%通过跟踪衍生的保持检测恢复,并从每次插入分析中排除)。间歇性跟踪冻结伪影,其中静态姿态保留在有效的跟踪标志下,通过帧到帧的不动来检测并排除在受影响的分析之外。所有节段的平均插入峰值左手腕旋转为107.9°,无旋转机制时为72.6°。每次支气管镜检查左拇指在手腕局部参考框架内的平均路径长度为3.82±0.48 m,每次手术估计支气管镜杠杆操作周期为64.8±7.9次。结论:在这项概念验证研究中,一个现成的头戴式设备可以在模拟支气管镜检查期间实现支气管镜检查者运动学的多通道捕获。该方法为支气管镜检查人体工程学、技能评估和人工智能驱动的训练数据生成的未来研究提供了实用的方法基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Respiration
Respiration 医学-呼吸系统
CiteScore
7.30
自引率
5.40%
发文量
82
审稿时长
4-8 weeks
期刊介绍: ''Respiration'' brings together the results of both clinical and experimental investigations on all aspects of the respiratory system in health and disease. Clinical improvements in the diagnosis and treatment of chest and lung diseases are covered, as are the latest findings in physiology, biochemistry, pathology, immunology and pharmacology. The journal includes classic features such as editorials that accompany original articles in clinical and basic science research, reviews and letters to the editor. Further sections are: Technical Notes, The Eye Catcher, What’s Your Diagnosis?, The Opinion Corner, New Drugs in Respiratory Medicine, New Insights from Clinical Practice and Guidelines. ''Respiration'' is the official journal of the Swiss Society for Pneumology (SGP) and also home to the European Association for Bronchology and Interventional Pulmonology (EABIP), which occupies a dedicated section on Interventional Pulmonology in the journal. This modern mix of different features and a stringent peer-review process by a dedicated editorial board make ''Respiration'' a complete guide to progress in thoracic medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书