James Endersby, Holly Mills, Humayra Dervin, Minerva De Silva, Natalia Zarate-Lopez, Rami Sweis
{"title":"High-resolution Manometry Catheter Insertion During Sedated Endoscopy; A Viable Option When Standard Intubation Fails.","authors":"James Endersby, Holly Mills, Humayra Dervin, Minerva De Silva, Natalia Zarate-Lopez, Rami Sweis","doi":"10.5056/jnm25240","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aims: </strong>: When high-resolution manometry (HRM) intubation is not tolerated or the catheter fails to traverse the lower esophageal sphincter, the test is often abandoned, leaving patients without a diagnosis to guide therapy. Although endoscopic placement of HRM catheters under sedation has been described, no study has directly compared this approach with routine outpatient HRM. This study provides the first direct comparison of sedated endoscopic insertion (EI) versus routine insertion (RI).</p><p><strong>Methods: </strong>: All patients who underwent EI of the HRM catheter between January 2020 and May 2025 were retrospectively reviewed and compared with a contemporaneous cohort who had RI. Each test included the standard protocol of ten 5 mL water swallows followed by a 200 g rice meal. Demographic data, endoscopic technique, sedation levels and manometric diagnoses were evaluated. Esophageal body function was defined in accordance with the Chicago classification version 4.0.</p><p><strong>Results: </strong>: Of 88 patients who had EI attempted, 79 (89.8%) were successfully intubated to the stomach and 78 (88.6%) completed the full swallow protocol. Endoscopic visualization was required for passage through the cricopharynx in 47 (53.4%) and through the esophagogastric junction in 23 (26.1%), with manual guidance needed in 8 (9.1%). Intubation success was comparable to routine insertion (RI) (89.8% EI vs 80.7% RI; <i>P</i> = 0.089) but protocol completion was higher (88.6% EI vs 72.7%; <i>P</i> = 0.008). No adverse events occurred.</p><p><strong>Conclusions: </strong>: Sedated EI of the HRM catheter enables protocol completion for patients unable to undergo routine testing, filling a key diagnostic gap while delivering manometric results comparable to standard, unsedated studies.</p>","PeriodicalId":16543,"journal":{"name":"Journal of Neurogastroenterology and Motility","volume":" ","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2026-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neurogastroenterology and Motility","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5056/jnm25240","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background/aims: : When high-resolution manometry (HRM) intubation is not tolerated or the catheter fails to traverse the lower esophageal sphincter, the test is often abandoned, leaving patients without a diagnosis to guide therapy. Although endoscopic placement of HRM catheters under sedation has been described, no study has directly compared this approach with routine outpatient HRM. This study provides the first direct comparison of sedated endoscopic insertion (EI) versus routine insertion (RI).
Methods: : All patients who underwent EI of the HRM catheter between January 2020 and May 2025 were retrospectively reviewed and compared with a contemporaneous cohort who had RI. Each test included the standard protocol of ten 5 mL water swallows followed by a 200 g rice meal. Demographic data, endoscopic technique, sedation levels and manometric diagnoses were evaluated. Esophageal body function was defined in accordance with the Chicago classification version 4.0.
Results: : Of 88 patients who had EI attempted, 79 (89.8%) were successfully intubated to the stomach and 78 (88.6%) completed the full swallow protocol. Endoscopic visualization was required for passage through the cricopharynx in 47 (53.4%) and through the esophagogastric junction in 23 (26.1%), with manual guidance needed in 8 (9.1%). Intubation success was comparable to routine insertion (RI) (89.8% EI vs 80.7% RI; P = 0.089) but protocol completion was higher (88.6% EI vs 72.7%; P = 0.008). No adverse events occurred.
Conclusions: : Sedated EI of the HRM catheter enables protocol completion for patients unable to undergo routine testing, filling a key diagnostic gap while delivering manometric results comparable to standard, unsedated studies.
背景/目的:当高分辨率测压(HRM)插管不能耐受或导管不能穿过食管下括约肌时,通常会放弃该测试,使患者无法诊断以指导治疗。虽然在镇静下内镜下放置HRM导管已经被描述过,但没有研究直接将这种方法与常规门诊HRM进行比较。这项研究提供了第一次直接比较镇静内窥镜插入(EI)与常规插入(RI)。方法:回顾性分析2020年1月至2025年5月期间所有接受HRM导管EI的患者,并与同期的RI患者进行比较。每个测试都包括10次5毫升水吞下,然后是200克米饭。评估人口统计学资料、内镜技术、镇静水平和测压诊断。食道体功能按照芝加哥分类4.0版进行定义。结果:88例EI患者中,79例(89.8%)成功插管至胃,78例(88.6%)完成全吞咽方案。47例(53.4%)通过环咽部,23例(26.1%)通过食管胃交界处,需要内镜显示,8例(9.1%)需要人工引导。插管成功率与常规插入(RI)相当(89.8% EI vs 80.7% RI, P = 0.089),但方案完成率更高(88.6% EI vs 72.7%, P = 0.008)。无不良事件发生。结论:HRM导管的镇静EI使无法进行常规检测的患者能够完成方案,填补了关键的诊断空白,同时提供了与标准非镇静研究相当的血压测量结果。
期刊介绍:
Journal of Neurogastroenterology and Motility (J Neurogastroenterol Motil) is a joint official journal of the Korean Society of Neurogastroenterology and Motility, the Thai Neurogastroenterology and Motility Society, the Japanese Society of Neurogastroenterology and Motility, the Indian Motility and Functional Disease Association, the Chinese Society of Gastrointestinal Motility, the South East Asia Gastro-Neuro Motility Association, the Taiwan Neurogastroenterology and Motility Society and the Asian Neurogastroenterology and Motility Association, launched in January 2010 after the title change from the Korean Journal of Neurogastroenterology and Motility, published from 1994 to 2009.