{"title":"Clinical Implementation of Wearable-Derived Sleep and Activity Reporting for Inpatient Psychiatric Monitoring.","authors":"Brien William Culhane, Robert Dennis Patterson, Habiballah Rahimi-Eichi, Agustin Go Yip, Kayla Huesman, Kristin Kostick-Quenet, Joshua Salvi, Philippe Beauchamp, Kerry James Ressler, Justin Taylor Baker","doi":"10.2196/88466","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Sleep is a core component of psychiatric assessment, yet inpatient monitoring typically relies on brief observational checks that are subjective, variable, and sometimes disruptive. Wearable devices offer a means of capturing continuous, objective sleep and activity data without disturbing patients. Although digital health technologies are increasingly used in psychiatric research, little is known about how wearable-derived data can be integrated into routine inpatient workflows or used meaningfully by clinicians.</p><p><strong>Objective: </strong>This implementation aimed to evaluate the feasibility, usability, and workflow integration of a wearable-derived sleep and activity reporting system within an adult psychiatric inpatient unit.</p><p><strong>Methods: </strong>The implementation unfolded in 2 phases at a single 21-bed adult inpatient unit at a psychiatric hospital in Massachusetts. Patients were offered a wrist-worn GENEActiv actigraphy device upon admission. Raw accelerometry data were processed using the DPSleep pipeline to derive daily sleep and activity metrics for patients participating in the implementation. Sleep and activity reports combining graphical summaries and natural language summaries of sleep, activity, and medication data were iteratively refined and delivered to psychiatrists providing patient care. Semistructured qualitative interviews were conducted with clinicians and unit staff to gather feedback on the sleep and activity report prototype and discuss barriers to and facilitators of implementation. Interview data were coded and analyzed by a team of 2.</p><p><strong>Unlabelled: </strong>During phase 1 of the implementation, 155 patients were admitted, of whom 88 (56.8%) were offered a device and 68 (77.3%) accepted it. Sleep and activity reports were generated for 61.8% (42/68) of patients wearing a device during this phase. During phase 2 of the implementation, automation reduced report generation time from approximately 5 days to under 24 hours. Only 1 of the 3 psychiatrists on the unit regularly used the reports in routine care. Reports were most useful for reconciling discrepancies between patient and nursing sleep estimates and for supporting clinical conversations about sleep patterns and medication adherence between clinician and patient. Clinicians who had not yet used the reports expressed conceptual interest but emphasized the need for integration in the electronic medical record, reliably available \"last-night\" sleep data, and simplified design. Barriers included challenges in the speed, reliability, and clarity of the data; variable staff buy-in; and disconnects between the research and clinical teams running the implementation.</p><p><strong>Conclusions: </strong>This implementation suggests that wearable-derived sleep and activity data reporting is technically feasible in inpatient psychiatry. This data reporting potentially offers clinically meaningful insights. Use of the reports was concentrated in 1 of the 3 psychiatrists on the unit, who served as an early adopter and project champion (AGY). Sustainable use and broad clinical uptake are more likely with reliable, near-instantaneous data transfer; electronic medical record integration; and shared implementation ownership across staff levels.</p>","PeriodicalId":14841,"journal":{"name":"JMIR Formative Research","volume":"10 ","pages":"e88466"},"PeriodicalIF":2.4000,"publicationDate":"2026-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13592238/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR Formative Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/88466","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Sleep is a core component of psychiatric assessment, yet inpatient monitoring typically relies on brief observational checks that are subjective, variable, and sometimes disruptive. Wearable devices offer a means of capturing continuous, objective sleep and activity data without disturbing patients. Although digital health technologies are increasingly used in psychiatric research, little is known about how wearable-derived data can be integrated into routine inpatient workflows or used meaningfully by clinicians.

Objective: This implementation aimed to evaluate the feasibility, usability, and workflow integration of a wearable-derived sleep and activity reporting system within an adult psychiatric inpatient unit.

Methods: The implementation unfolded in 2 phases at a single 21-bed adult inpatient unit at a psychiatric hospital in Massachusetts. Patients were offered a wrist-worn GENEActiv actigraphy device upon admission. Raw accelerometry data were processed using the DPSleep pipeline to derive daily sleep and activity metrics for patients participating in the implementation. Sleep and activity reports combining graphical summaries and natural language summaries of sleep, activity, and medication data were iteratively refined and delivered to psychiatrists providing patient care. Semistructured qualitative interviews were conducted with clinicians and unit staff to gather feedback on the sleep and activity report prototype and discuss barriers to and facilitators of implementation. Interview data were coded and analyzed by a team of 2.

Unlabelled: During phase 1 of the implementation, 155 patients were admitted, of whom 88 (56.8%) were offered a device and 68 (77.3%) accepted it. Sleep and activity reports were generated for 61.8% (42/68) of patients wearing a device during this phase. During phase 2 of the implementation, automation reduced report generation time from approximately 5 days to under 24 hours. Only 1 of the 3 psychiatrists on the unit regularly used the reports in routine care. Reports were most useful for reconciling discrepancies between patient and nursing sleep estimates and for supporting clinical conversations about sleep patterns and medication adherence between clinician and patient. Clinicians who had not yet used the reports expressed conceptual interest but emphasized the need for integration in the electronic medical record, reliably available "last-night" sleep data, and simplified design. Barriers included challenges in the speed, reliability, and clarity of the data; variable staff buy-in; and disconnects between the research and clinical teams running the implementation.

Conclusions: This implementation suggests that wearable-derived sleep and activity data reporting is technically feasible in inpatient psychiatry. This data reporting potentially offers clinically meaningful insights. Use of the reports was concentrated in 1 of the 3 psychiatrists on the unit, who served as an early adopter and project champion (AGY). Sustainable use and broad clinical uptake are more likely with reliable, near-instantaneous data transfer; electronic medical record integration; and shared implementation ownership across staff levels.

用于住院病人精神监测的可穿戴式睡眠和活动报告的临床实施。
背景:睡眠是精神病评估的核心组成部分,然而住院病人的监测通常依赖于主观的、可变的、有时是破坏性的简短观察检查。可穿戴设备提供了一种捕捉连续、客观的睡眠和活动数据的方法,而不会打扰患者。尽管数字健康技术越来越多地用于精神病学研究,但人们对如何将可穿戴设备衍生的数据整合到日常住院工作流程中或由临床医生有意义地使用知之甚少。目的:本实施旨在评估可穿戴式睡眠和活动报告系统在成人精神病住院病房的可行性、可用性和工作流程集成。方法:在马萨诸塞州一家精神病院21张床位的成人住院病房分两个阶段实施。入院时为患者提供腕戴式geneactive活动记录仪。使用DPSleep管道处理原始加速度计数据,以获得参与实施的患者的日常睡眠和活动指标。结合睡眠、活动和药物数据的图形摘要和自然语言摘要的睡眠和活动报告被迭代地改进并交付给提供患者护理的精神科医生。与临床医生和单位工作人员进行了半结构化定性访谈,以收集关于睡眠和活动报告原型的反馈,并讨论实施的障碍和促进因素。访谈数据由一个2人的团队进行编码和分析。未标记:在实施的第一阶段,155名患者入院,其中88名(56.8%)患者获得了设备,68名(77.3%)患者接受了设备。在这一阶段,61.8%(42/68)的佩戴设备的患者生成了睡眠和活动报告。在实现的第2阶段,自动化将报告生成时间从大约5天减少到不到24小时。该部门的3名精神病医生中只有1名在日常护理中定期使用这些报告。报告对于调和患者和护理人员睡眠估计之间的差异,以及支持临床医生和患者之间关于睡眠模式和药物依从性的临床对话最有用。尚未使用报告的临床医生表达了概念上的兴趣,但强调需要整合电子病历,可靠地获得“昨晚”睡眠数据,并简化设计。障碍包括数据的速度、可靠性和清晰度方面的挑战;可变员工支持;研究团队和临床团队之间的脱节。结论:这一实现表明,可穿戴式睡眠和活动数据报告在住院精神病学中在技术上是可行的。该数据报告可能提供有临床意义的见解。报告的使用集中在该单位的3名精神科医生中的1名,他是早期采用者和项目倡导者(AGY)。可靠的、近乎即时的数据传输更有可能实现可持续使用和广泛的临床应用;电子病历集成;并在员工级别之间共享实现所有权。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JMIR Formative Research
JMIR Formative Research Medicine-Medicine (miscellaneous)
CiteScore
2.70
自引率
9.10%
发文量
579
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书