Functional dermoscopy integrated by cellular-resolution Mirau-based optical coherence microscopy.

IF 3.2 2区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Biomedical optics express Pub Date : 2026-08-07 eCollection Date: 2026-09-01 DOI:10.1364/BOE.606649
Chien-Chung Tsai, Hsiang-Chieh Lee, Yen-Po Tsao, Akihiko Yoshizawa, Chong Li, Sheng-Lung Huang
{"title":"Functional dermoscopy integrated by cellular-resolution Mirau-based optical coherence microscopy.","authors":"Chien-Chung Tsai, Hsiang-Chieh Lee, Yen-Po Tsao, Akihiko Yoshizawa, Chong Li, Sheng-Lung Huang","doi":"10.1364/BOE.606649","DOIUrl":null,"url":null,"abstract":"<p><p>A Mirau-based optical coherence microscopy (OCM) with dual-modality is proposed to image cellular-level three-dimensional (3-D) skin morphology by OCM mode and to observe the blood circulation beneath the basal layer with an in-built orthogonal polarization spectral imaging (OPSI) mode. With the property of OCM, this system has sub-micron (0.9 μm in axis, 0.8 μm in transverse) spatial resolution in the volumetric dimension of 285 (length) × 215 (width) × 100 (depth) μm<sup>3</sup> collected in 2 minutes from <i>in-vivo</i> skin tissue. By switching the optical component of an achromatic quarter-wave plate, a video-rate OPSI system is performed to count the red blood cells (RBCs) and to measure the projected capillary flow speed (CFS) of RBCs. Combining phase-shifted <i>en-face</i> frame OCM morphology and color-coding OPSI circulation, the analyses of CFS and count of RBCs were demonstrated. In addition, the size of a single RBC was determined via <i>en-face</i> and tomographic images. A dermoscope combining OCM and OPSI modes was achieved via a common high-brightness visible light source using a diode-pumped Ce<sup>3+</sup>:YAG single-clad crystal fiber.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"17 9","pages":"4553-4567"},"PeriodicalIF":3.2000,"publicationDate":"2026-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13592267/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.606649","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

A Mirau-based optical coherence microscopy (OCM) with dual-modality is proposed to image cellular-level three-dimensional (3-D) skin morphology by OCM mode and to observe the blood circulation beneath the basal layer with an in-built orthogonal polarization spectral imaging (OPSI) mode. With the property of OCM, this system has sub-micron (0.9 μm in axis, 0.8 μm in transverse) spatial resolution in the volumetric dimension of 285 (length) × 215 (width) × 100 (depth) μm3 collected in 2 minutes from in-vivo skin tissue. By switching the optical component of an achromatic quarter-wave plate, a video-rate OPSI system is performed to count the red blood cells (RBCs) and to measure the projected capillary flow speed (CFS) of RBCs. Combining phase-shifted en-face frame OCM morphology and color-coding OPSI circulation, the analyses of CFS and count of RBCs were demonstrated. In addition, the size of a single RBC was determined via en-face and tomographic images. A dermoscope combining OCM and OPSI modes was achieved via a common high-brightness visible light source using a diode-pumped Ce3+:YAG single-clad crystal fiber.

基于细胞分辨率mirau的光学相干显微镜集成的功能性皮肤镜。
提出了一种基于mirau的双模光学相干显微镜(OCM),通过OCM模式对细胞级三维(3d)皮肤形态进行成像,并通过内置的正交偏振光谱成像(OPSI)模式观察基底层下的血液循环。该系统具有亚微米(轴线0.9 μm,横向0.8 μm)的空间分辨率,可在2分钟内采集到285(长)× 215(宽)× 100(深)μm3的体内皮肤组织。通过切换消色差四分之一波片的光学元件,视频速率OPSI系统可以计数红细胞(rbc)并测量红细胞的预测毛细管流速(CFS)。结合相移面框OCM形态学和颜色编码OPSI循环,对CFS和红细胞计数进行了分析。此外,单个红细胞的大小通过正面和断层图像确定。通过使用二极管泵浦Ce3+:YAG单晶光纤的普通高亮度可见光源,实现了结合OCM和OPSI模式的皮肤镜。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical optics express
Biomedical optics express BIOCHEMICAL RESEARCH METHODS-OPTICS
CiteScore
6.80
自引率
11.80%
发文量
633
审稿时长
1 months
期刊介绍: The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including: Tissue optics and spectroscopy Novel microscopies Optical coherence tomography Diffuse and fluorescence tomography Photoacoustic and multimodal imaging Molecular imaging and therapies Nanophotonic biosensing Optical biophysics/photobiology Microfluidic optical devices Vision research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书