Depth-adapted adaptive optics for three-photon microscopy.

IF 3.2 2区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Biomedical optics express Pub Date : 2026-08-13 eCollection Date: 2026-09-01 DOI:10.1364/BOE.609127
Qi Hu, Jingyu Wang, Huriye Atilgan, Armin Lak, Martin J Booth
{"title":"Depth-adapted adaptive optics for three-photon microscopy.","authors":"Qi Hu, Jingyu Wang, Huriye Atilgan, Armin Lak, Martin J Booth","doi":"10.1364/BOE.609127","DOIUrl":null,"url":null,"abstract":"<p><p>Three-photon (3-P) fluorescence microscopy enables deep in vivo imaging with subcellular resolution, but its performance is fundamentally constrained by the maximum permissible laser power required to avoid tissue heating and photodamage. Under these power-limited conditions, fluorescence signal generation, image contrast, and achievable imaging depth are strongly affected by the illumination beam profile and aberration correction strategy. In this paper, we showed that using a fixed illumination beam size was suboptimal across different imaging depths. We further showed that conventional Zernike-based adaptive optics (AO) correction degrades under reduced Gaussian illumination beam sizes due to loss of modal orthogonality. This degradation results in slow convergence, unintended focal and field-of-view shifts, and excessive wavefront deformations. To overcome these limitations, we introduced a depth-adapted AO framework in which both the illumination beam profile and the aberration correction basis were dynamically matched to the imaging conditions. By combining depth-optimised beam underfilling with a bespoke set of illumination-matched aberration modes, we achieved faster and more stable AO convergence, enhanced fluorescence signal, and image quality during deep in vivo multi-channel neuroimaging. Together, these results established a practical and robust AO-enabled three-photon microscopy strategy that enhanced imaging performance under realistic power constraints.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"17 9","pages":"4605-4616"},"PeriodicalIF":3.2000,"publicationDate":"2026-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13592269/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.609127","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Three-photon (3-P) fluorescence microscopy enables deep in vivo imaging with subcellular resolution, but its performance is fundamentally constrained by the maximum permissible laser power required to avoid tissue heating and photodamage. Under these power-limited conditions, fluorescence signal generation, image contrast, and achievable imaging depth are strongly affected by the illumination beam profile and aberration correction strategy. In this paper, we showed that using a fixed illumination beam size was suboptimal across different imaging depths. We further showed that conventional Zernike-based adaptive optics (AO) correction degrades under reduced Gaussian illumination beam sizes due to loss of modal orthogonality. This degradation results in slow convergence, unintended focal and field-of-view shifts, and excessive wavefront deformations. To overcome these limitations, we introduced a depth-adapted AO framework in which both the illumination beam profile and the aberration correction basis were dynamically matched to the imaging conditions. By combining depth-optimised beam underfilling with a bespoke set of illumination-matched aberration modes, we achieved faster and more stable AO convergence, enhanced fluorescence signal, and image quality during deep in vivo multi-channel neuroimaging. Together, these results established a practical and robust AO-enabled three-photon microscopy strategy that enhanced imaging performance under realistic power constraints.

用于三光子显微镜的深度自适应光学。
三光子(3-P)荧光显微镜能够实现亚细胞分辨率的深部体内成像,但其性能从根本上受到最大允许激光功率的限制,以避免组织加热和光损伤。在这些功率有限的条件下,荧光信号的产生、图像对比度和可实现的成像深度受到照明光束轮廓和像差校正策略的强烈影响。在本文中,我们证明了在不同的成像深度下,使用固定的照明光束尺寸是次优的。我们进一步表明,由于模态正交性的丧失,传统的基于zernike的自适应光学(AO)校正在减小高斯照明光束尺寸下会下降。这种退化导致缓慢的收敛,意想不到的焦点和视野偏移,以及过度的波前变形。为了克服这些限制,我们引入了一种深度自适应AO框架,其中光照光束轮廓和像差校正基都与成像条件动态匹配。通过将深度优化的光束下填充与定制的光照匹配像差模式相结合,我们在体内深部多通道神经成像中实现了更快、更稳定的AO收敛、增强的荧光信号和图像质量。总之,这些结果建立了一个实用和强大的支持ao的三光子显微镜策略,增强了现实功率限制下的成像性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical optics express
Biomedical optics express BIOCHEMICAL RESEARCH METHODS-OPTICS
CiteScore
6.80
自引率
11.80%
发文量
633
审稿时长
1 months
期刊介绍: The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including: Tissue optics and spectroscopy Novel microscopies Optical coherence tomography Diffuse and fluorescence tomography Photoacoustic and multimodal imaging Molecular imaging and therapies Nanophotonic biosensing Optical biophysics/photobiology Microfluidic optical devices Vision research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书