{"title":"Method Development and Validation of Promethazine HCl by Using RP-HPLC and Its Forced Degradation Studies.","authors":"Deepshikha Nirwan, Kandasamy Nagarajan, Parul Grover, Snigdha Bhardwaj, Ashutosh Mishra","doi":"10.1177/1540658X261486549","DOIUrl":null,"url":null,"abstract":"<p><p>\n <i>A simple, rapid, sensitive, and stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the quantitative determination of promethazine hydrochloride (HCl) in pharmaceutical formulations. Chromatographic separation was achieved using a SunFire® C18 column (4.6 × 250 mm, 5 µm) with a mobile phase consisting of acetonitrile and 0.1% orthophosphoric acid in water (80:20, v/v) at a flow rate of 1.0 mL/min. Detection was performed at 249 nm using a photodiode array detector. The developed method was validated according to the International Council for Harmonisation Q2 guidelines with respect to specificity, linearity, precision, accuracy, robustness, limit of detection, and limit of quantitation.The method exhibited good linearity over the concentration range of 2-64 µg/mL with a correlation coefficient (<i>R</i><sup>2</sup>) of 0.9993. The percentage relative standard deviation for precision studies was below 2%, indicating satisfactory repeatability and reproducibility. Forced degradation studies were performed under acidic, alkaline, neutral, oxidative, and thermal stress conditions to evaluate the stability indicating capability of the method. Additional chromatographic peaks corresponding to degradation products were observed in acid, base, neutral, and oxidative stress conditions, while minimal degradation was observed under thermal stress. Furthermore, liquid chromatography-mass spectrometry (LC-MS) analysis was carried out to characterize the degradation products formed during stress studies. LC-MS results indicated that alkaline stress produced the highest degree of degradation, whereas thermal stress generated only minor residual impurities, confirming the relative stability of promethazine HCl under thermal conditions. The developed RP-HPLC method was found to be suitable for routine quality control analysis and stability assessment of promethazine HCl in pharmaceutical formulations.</i>\n </p>","PeriodicalId":8586,"journal":{"name":"Assay and drug development technologies","volume":" ","pages":"1540658X261486549"},"PeriodicalIF":1.8000,"publicationDate":"2026-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Assay and drug development technologies","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/1540658X261486549","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
A simple, rapid, sensitive, and stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the quantitative determination of promethazine hydrochloride (HCl) in pharmaceutical formulations. Chromatographic separation was achieved using a SunFire® C18 column (4.6 × 250 mm, 5 µm) with a mobile phase consisting of acetonitrile and 0.1% orthophosphoric acid in water (80:20, v/v) at a flow rate of 1.0 mL/min. Detection was performed at 249 nm using a photodiode array detector. The developed method was validated according to the International Council for Harmonisation Q2 guidelines with respect to specificity, linearity, precision, accuracy, robustness, limit of detection, and limit of quantitation.The method exhibited good linearity over the concentration range of 2-64 µg/mL with a correlation coefficient (R2) of 0.9993. The percentage relative standard deviation for precision studies was below 2%, indicating satisfactory repeatability and reproducibility. Forced degradation studies were performed under acidic, alkaline, neutral, oxidative, and thermal stress conditions to evaluate the stability indicating capability of the method. Additional chromatographic peaks corresponding to degradation products were observed in acid, base, neutral, and oxidative stress conditions, while minimal degradation was observed under thermal stress. Furthermore, liquid chromatography-mass spectrometry (LC-MS) analysis was carried out to characterize the degradation products formed during stress studies. LC-MS results indicated that alkaline stress produced the highest degree of degradation, whereas thermal stress generated only minor residual impurities, confirming the relative stability of promethazine HCl under thermal conditions. The developed RP-HPLC method was found to be suitable for routine quality control analysis and stability assessment of promethazine HCl in pharmaceutical formulations.
期刊介绍:
ASSAY and Drug Development Technologies provides access to novel techniques and robust tools that enable critical advances in early-stage screening. This research published in the Journal leads to important therapeutics and platforms for drug discovery and development. This reputable peer-reviewed journal features original papers application-oriented technology reviews, topical issues on novel and burgeoning areas of research, and reports in methodology and technology application.
ASSAY and Drug Development Technologies coverage includes:
-Assay design, target development, and high-throughput technologies-
Hit to Lead optimization and medicinal chemistry through preclinical candidate selection-
Lab automation, sample management, bioinformatics, data mining, virtual screening, and data analysis-
Approaches to assays configured for gene families, inherited, and infectious diseases-
Assays and strategies for adapting model organisms to drug discovery-
The use of stem cells as models of disease-
Translation of phenotypic outputs to target identification-
Exploration and mechanistic studies of the technical basis for assay and screening artifacts