Super-resolution imaging using fluorescence-lifetime emission-difference.

IF 3.2 2区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Biomedical optics express Pub Date : 2026-08-05 eCollection Date: 2026-09-01 DOI:10.1364/BOE.600223
Wonsang Hwang, Nicolas Mateos, Pablo Loza-Alvarez, Nadia Halidi, Conor L Evans, Iván Coto Hernández
{"title":"Super-resolution imaging using fluorescence-lifetime emission-difference.","authors":"Wonsang Hwang, Nicolas Mateos, Pablo Loza-Alvarez, Nadia Halidi, Conor L Evans, Iván Coto Hernández","doi":"10.1364/BOE.600223","DOIUrl":null,"url":null,"abstract":"<p><p>The diffraction of light limits the ability of light microscopes to resolve biological structures and intracellular processes with nanoscale spatial information. Fluorescence emission difference (FED) improves image contrast and effective spatial resolution of confocal microscopy by alternating the excitation of the sample with a Gaussian and donut-shaped laser beam. Improvement in image resolution is obtained by subtracting images captured with both excitation modes. The combination of this technique with fluorescence lifetime imaging microscopy (FLIM) has remained limited. Here, we propose a super-resolution fluorescence-lifetime emission-difference (FLED) microscopy approach obtained through a multi-image weighted-subtraction algorithm that combines images reconstructed from multiple temporal bins. A high-throughput implementation was demonstrated using a commercial time-resolved stimulated-emission depletion microscope (STED). Through simulations of fluorescent beads and experimental validation on biological samples, we demonstrated a 1.6× resolution enhancement corresponding to 0.22<i>λ</i> (154 nm). The proposed FLED method enables simultaneous imaging of multiple fluorescent targets and, unlike conventional super-resolution methods, requires lower excitation power and is compatible with a wide range of fluorescent dyes.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"17 9","pages":"4524-4539"},"PeriodicalIF":3.2000,"publicationDate":"2026-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13592273/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.600223","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The diffraction of light limits the ability of light microscopes to resolve biological structures and intracellular processes with nanoscale spatial information. Fluorescence emission difference (FED) improves image contrast and effective spatial resolution of confocal microscopy by alternating the excitation of the sample with a Gaussian and donut-shaped laser beam. Improvement in image resolution is obtained by subtracting images captured with both excitation modes. The combination of this technique with fluorescence lifetime imaging microscopy (FLIM) has remained limited. Here, we propose a super-resolution fluorescence-lifetime emission-difference (FLED) microscopy approach obtained through a multi-image weighted-subtraction algorithm that combines images reconstructed from multiple temporal bins. A high-throughput implementation was demonstrated using a commercial time-resolved stimulated-emission depletion microscope (STED). Through simulations of fluorescent beads and experimental validation on biological samples, we demonstrated a 1.6× resolution enhancement corresponding to 0.22λ (154 nm). The proposed FLED method enables simultaneous imaging of multiple fluorescent targets and, unlike conventional super-resolution methods, requires lower excitation power and is compatible with a wide range of fluorescent dyes.

使用荧光寿命发射差的超分辨率成像。
光的衍射限制了光学显微镜用纳米尺度的空间信息来解析生物结构和细胞内过程的能力。荧光发射差(FED)通过高斯和环形激光束交替激发样品,提高了共聚焦显微镜的图像对比度和有效空间分辨率。通过减去用两种激励模式捕获的图像,获得了图像分辨率的提高。该技术与荧光寿命成像显微镜(FLIM)的结合仍然有限。在这里,我们提出了一种超分辨率荧光寿命发射差(逃离)显微镜方法,该方法通过多图像加权减去算法获得,该算法结合了从多个时间箱重建的图像。使用商用时间分辨激发发射耗尽显微镜(STED)演示了高通量实现。通过荧光珠的模拟和生物样品的实验验证,我们证明了对应于0.22λ (154 nm)的1.6倍分辨率增强。该方法能够同时成像多个荧光目标,与传统的超分辨率方法不同,它需要更低的激发功率,并且与广泛的荧光染料兼容。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical optics express
Biomedical optics express BIOCHEMICAL RESEARCH METHODS-OPTICS
CiteScore
6.80
自引率
11.80%
发文量
633
审稿时长
1 months
期刊介绍: The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including: Tissue optics and spectroscopy Novel microscopies Optical coherence tomography Diffuse and fluorescence tomography Photoacoustic and multimodal imaging Molecular imaging and therapies Nanophotonic biosensing Optical biophysics/photobiology Microfluidic optical devices Vision research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书