George Tian Funkenbusch, Rick Laoprasert, Nipun T Hewage, Arizona Greene, Joseph A Izatt, Anthony N Kuo, Ryan P McNabb
{"title":"Motion-corrected Gaussian, mean, and parametric curvature mapping of the posterior eye with pupil-tracked whole-eye OCT.","authors":"George Tian Funkenbusch, Rick Laoprasert, Nipun T Hewage, Arizona Greene, Joseph A Izatt, Anthony N Kuo, Ryan P McNabb","doi":"10.1364/BOE.606681","DOIUrl":null,"url":null,"abstract":"<p><p>Optical coherence tomography (OCT) is a promising alternative to magnetic resonance imaging (MRI) for accessible, high-resolution measurement of posterior eye curvature, including for applications such as exploration of local eye shape deformations in pathologic myopia. However, OCT is a point-scanning interferometric imaging method that spatially encodes the effects of patient motion during acquisition into an acquired volume. These motion artifacts reduce accuracy and increase intra-acquisition variation in measured curvature, reducing the utility of OCT for monitoring posterior eye curvatures longitudinally. We present a method utilizing 3D pupil tracking and sparse orthogonal scanning for post-acquisition correction of motion artifacts in posterior eye OCT volumes and their corresponding curvature maps. We imaged six subjects exhibiting moderate (-6.0 to -3.0 D) to high (<-6.0 D) myopia and demonstrate a reduction in intra-session curvature variability when using our pupil tracking motion correction scheme. We also propose alternative metrics for representing 2-dimensional posterior eye curvature data to researchers and clinicians.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"17 9","pages":"4741-4760"},"PeriodicalIF":3.2000,"publicationDate":"2026-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13592249/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.606681","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Optical coherence tomography (OCT) is a promising alternative to magnetic resonance imaging (MRI) for accessible, high-resolution measurement of posterior eye curvature, including for applications such as exploration of local eye shape deformations in pathologic myopia. However, OCT is a point-scanning interferometric imaging method that spatially encodes the effects of patient motion during acquisition into an acquired volume. These motion artifacts reduce accuracy and increase intra-acquisition variation in measured curvature, reducing the utility of OCT for monitoring posterior eye curvatures longitudinally. We present a method utilizing 3D pupil tracking and sparse orthogonal scanning for post-acquisition correction of motion artifacts in posterior eye OCT volumes and their corresponding curvature maps. We imaged six subjects exhibiting moderate (-6.0 to -3.0 D) to high (<-6.0 D) myopia and demonstrate a reduction in intra-session curvature variability when using our pupil tracking motion correction scheme. We also propose alternative metrics for representing 2-dimensional posterior eye curvature data to researchers and clinicians.
期刊介绍:
The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including:
Tissue optics and spectroscopy
Novel microscopies
Optical coherence tomography
Diffuse and fluorescence tomography
Photoacoustic and multimodal imaging
Molecular imaging and therapies
Nanophotonic biosensing
Optical biophysics/photobiology
Microfluidic optical devices
Vision research.