{"title":"A multiparameter model combining ultrasound and maternal serum biomarkers accurately predicts late-onset fetal growth restriction.","authors":"Yaqin Li, Botao Yang, Liman Fu, Wei Zhang","doi":"10.62347/FAHT7495","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Late-onset fetal growth restriction (FGR) in pregnancy is frequently encountered and is linked to adverse perinatal results. This investigation aimed to evaluate the clinical use of a multiparameter model combining ultrasound features and maternal serum biomarkers for late-onset FGR.</p><p><strong>Methods: </strong>A retrospective investigation was conducted on 350 pregnant women in their third trimester who received standard prenatal care between January 2021 and December 2025. Participants were divided into a late-onset FGR group (n = 175) and a normal fetal development group (n = 175) according to the Chinese expert consensus criteria. Ultrasound findings including fetal biometry and Doppler flow indices were measured. Maternal serum levels of soluble fms-like tyrosine kinase-1 (sFlt-1) and placental growth factor (PLGF) were quantified through enzyme-linked immunosorbent assay. Subsequently, the sFlt-1 to PLGF ratio (sFlt-1/PLGF) was calculated.</p><p><strong>Results: </strong>Among the 350 enrolled women, the FGR group exhibited markedly reduced abdominal circumference, estimated fetal weight, cerebroplacental ratio, and elevated uterine artery-pulsatility index and sFlt-1/PLGF compared to those in the normal group (all P < 0.05). The multiparameter evaluation model achieved an area under the curve of 0.977, demonstrating a sensitivity of 91.4% and specificity of 92.6% at the optimal threshold.</p><p><strong>Conclusions: </strong>The multiparameter model integrating ultrasound features and maternal serum biomarkers demonstrated excellent predictive performance for late-onset FGR, supporting its clinical use for early identification and management.</p>","PeriodicalId":7731,"journal":{"name":"American journal of translational research","volume":"18 8","pages":"6735-6745"},"PeriodicalIF":1.8000,"publicationDate":"2026-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13590679/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of translational research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.62347/FAHT7495","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Late-onset fetal growth restriction (FGR) in pregnancy is frequently encountered and is linked to adverse perinatal results. This investigation aimed to evaluate the clinical use of a multiparameter model combining ultrasound features and maternal serum biomarkers for late-onset FGR.
Methods: A retrospective investigation was conducted on 350 pregnant women in their third trimester who received standard prenatal care between January 2021 and December 2025. Participants were divided into a late-onset FGR group (n = 175) and a normal fetal development group (n = 175) according to the Chinese expert consensus criteria. Ultrasound findings including fetal biometry and Doppler flow indices were measured. Maternal serum levels of soluble fms-like tyrosine kinase-1 (sFlt-1) and placental growth factor (PLGF) were quantified through enzyme-linked immunosorbent assay. Subsequently, the sFlt-1 to PLGF ratio (sFlt-1/PLGF) was calculated.
Results: Among the 350 enrolled women, the FGR group exhibited markedly reduced abdominal circumference, estimated fetal weight, cerebroplacental ratio, and elevated uterine artery-pulsatility index and sFlt-1/PLGF compared to those in the normal group (all P < 0.05). The multiparameter evaluation model achieved an area under the curve of 0.977, demonstrating a sensitivity of 91.4% and specificity of 92.6% at the optimal threshold.
Conclusions: The multiparameter model integrating ultrasound features and maternal serum biomarkers demonstrated excellent predictive performance for late-onset FGR, supporting its clinical use for early identification and management.