Development of a graphene oxide-based PEGylated fluorescent aptasensor with ultrahigh-sensitivity and anti-fouling properties for the detection of serum carcinoembryonic antigen levels

IF 5.4 2区 化学 Q1 CHEMISTRY, ANALYTICAL
Qi Feng, Lu Xu, Ding-Fan Guo, Qi Wen, Yun-Hui Liang, Qi Huang, Ting Wang, Kun-He Zhang
{"title":"Development of a graphene oxide-based PEGylated fluorescent aptasensor with ultrahigh-sensitivity and anti-fouling properties for the detection of serum carcinoembryonic antigen levels","authors":"Qi Feng,&nbsp;Lu Xu,&nbsp;Ding-Fan Guo,&nbsp;Qi Wen,&nbsp;Yun-Hui Liang,&nbsp;Qi Huang,&nbsp;Ting Wang,&nbsp;Kun-He Zhang","doi":"10.1007/s00604-026-08412-w","DOIUrl":null,"url":null,"abstract":"<div><p>The specificity and sensitivity of aptamer-based serum biomarker assays can be compromised by nonspecific adsorption of proteins. In this study, we used the carcinoembryonic antigen (CEA) aptamer as a model to develop a fluorescent aptasensor capable of specifically and sensitively detecting serum biomarkers. This aptasensor employs the good antifouling capability of polyethylene glycol 2000 (P2K) to enhance specificity and the good fluorescence resonance energy transfer capability of graphene oxide (GO) to improve sensitivity. The aptasensor was applied to determine pure CEA protein and CEA in clinical serum and demonstrated that the P2K-modified fluorescent aptasensor exhibited significantly superior performance in CEA detection compared with the unmodified aptasensor, including accuracy, precision, linear range, antifouling properties, and selectivity. In the detection of CEA levels in clinical serum samples, the P2K-modified fluorescent aptasensor exhibited a lower limit of detection (LOD) (1.31 vs. 1.90 ng/mL), a wider linear range (1–256 vs. 1–64 ng/mL), better recovery (92.4%–103.6% vs. 73.3%–124.1%), and a smaller relative standard deviation (RSD) (0.7%-2.5% vs. 2.0%-6.4%). The aptasensor is capable of determining CEA levels within 90 min using only 1 µL of serum, with advantages of requiring no prefabrication of sensors, measuring fluorescence intensity in a conventional microplate reader, operating experimentally at room temperature, and high-throughput detection. Conclusively, this study successfully developed a GO-based P2K-modified fluorescent aptasensor capable of specifically, sensitively, and conveniently detecting CEA levels in clinical serum samples and with potential for clinical application.</p><h3>Graphical Abstract</h3><div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"193 10","pages":""},"PeriodicalIF":5.4000,"publicationDate":"2026-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-026-08412-w","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The specificity and sensitivity of aptamer-based serum biomarker assays can be compromised by nonspecific adsorption of proteins. In this study, we used the carcinoembryonic antigen (CEA) aptamer as a model to develop a fluorescent aptasensor capable of specifically and sensitively detecting serum biomarkers. This aptasensor employs the good antifouling capability of polyethylene glycol 2000 (P2K) to enhance specificity and the good fluorescence resonance energy transfer capability of graphene oxide (GO) to improve sensitivity. The aptasensor was applied to determine pure CEA protein and CEA in clinical serum and demonstrated that the P2K-modified fluorescent aptasensor exhibited significantly superior performance in CEA detection compared with the unmodified aptasensor, including accuracy, precision, linear range, antifouling properties, and selectivity. In the detection of CEA levels in clinical serum samples, the P2K-modified fluorescent aptasensor exhibited a lower limit of detection (LOD) (1.31 vs. 1.90 ng/mL), a wider linear range (1–256 vs. 1–64 ng/mL), better recovery (92.4%–103.6% vs. 73.3%–124.1%), and a smaller relative standard deviation (RSD) (0.7%-2.5% vs. 2.0%-6.4%). The aptasensor is capable of determining CEA levels within 90 min using only 1 µL of serum, with advantages of requiring no prefabrication of sensors, measuring fluorescence intensity in a conventional microplate reader, operating experimentally at room temperature, and high-throughput detection. Conclusively, this study successfully developed a GO-based P2K-modified fluorescent aptasensor capable of specifically, sensitively, and conveniently detecting CEA levels in clinical serum samples and with potential for clinical application.

Graphical Abstract

一种具有超高灵敏度和抗污染特性的氧化石墨烯基聚乙二醇荧光配体传感器的研制,用于检测血清癌胚抗原水平。
基于适配体的血清生物标志物检测的特异性和敏感性可能受到蛋白质非特异性吸附的影响。在这项研究中,我们以癌胚抗原(CEA)适体为模型,开发了一种能够特异性和敏感性检测血清生物标志物的荧光适体传感器。该传感器利用聚乙二醇2000 (P2K)良好的防污能力来增强特异性,利用氧化石墨烯(GO)良好的荧光共振能量转移能力来提高灵敏度。将该荧光体传感器用于检测纯CEA蛋白和临床血清中的CEA,结果表明,p2k修饰的荧光体传感器在CEA检测中表现出明显优于未修饰的荧光体传感器,包括准确性、精密度、线性范围、防污性能和选择性。在检测临床血清样品中CEA水平时,p2k修饰的荧光适体传感器具有较低的检出限(LOD) (1.31 vs 1.90 ng/mL)、较宽的线性范围(1 ~ 256 vs 1 ~ 64 ng/mL)、较好的回收率(92.4% ~ 103.6% vs 73.3% ~ 124.1%)和较小的相对标准偏差(RSD) (0.7% ~ 2.5% vs 2.0% ~ 6.4%)。该传感器仅使用1 μ L血清即可在90分钟内测定CEA水平,其优点是无需预先制作传感器,在传统的微孔板读取器中测量荧光强度,在室温下实验操作,以及高通量检测。总之,本研究成功开发了一种基于氧化石墨烯修饰的p2k荧光适体传感器,能够特异、灵敏、便捷地检测临床血清样品中的CEA水平,具有临床应用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书