Simplified bacterial identification and antimicrobial resistance detection in bacteraemia by on-chip multiplexed LAMP from blood cultures

IF 3.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Analyst Pub Date : 2026-09-22 DOI:10.1039/d5an01310k
Capucine Treille,Lilas Pommiès,Xenia Garcia Velasquez,Hervé Volland,Karla Perez-Toralla,Hervé Boutal
{"title":"Simplified bacterial identification and antimicrobial resistance detection in bacteraemia by on-chip multiplexed LAMP from blood cultures","authors":"Capucine Treille,Lilas Pommiès,Xenia Garcia Velasquez,Hervé Volland,Karla Perez-Toralla,Hervé Boutal","doi":"10.1039/d5an01310k","DOIUrl":null,"url":null,"abstract":"Bacteraemia is a life-threatening infection associated with substantial morbidity and mortality. Current diagnosis relies on blood culture followed by culture-based identification and antimicrobial susceptibility testing, which remain the clinical gold standard but require prolonged turnaround times. Isothermal amplification technologies such as loop-mediated isothermal amplification (LAMP) offer a rapid, cost-effective, and accessible alternative for pathogen identification and antimicrobial resistance detection directly from positive blood cultures, particularly in resource-limited settings. However, their widespread implementation remains constrained by sample preparation requirements and limited multiplexing capabilities. To address these challenges, we developed ALADIM (Accessible and integrated LAMP Analysis for multiplex Detection of Infectious agents in Microfluidics), an integrated microfluidic platform combining bacterial DNA extraction, multiplex on-chip LAMP amplification, and instrument-free amplicon detection by lateral flow immunoassay (LFIA). The complete workflow can be performed in less than two hours, compared with the 24-48 h typically required for conventional diagnostic methods. As a proof of concept, the system was designed to detect E. coli, the most frequently reported pathogen in bacteraemia, together with two clinically relevant antimicrobial resistance determinants, blaCTX-M-15 and blaOXA-48, as well as an internal positive control. The multiplex assay was first evaluated using 14 bacterial strains cultured in LB medium. Performance of the on-chip workflow was comparable to that of the reference method consisting of conventional tube-based LAMP followed by LFIA detection, achieving 100% sensitivity and >84% specificity for malF and blaOXA-48, and 68% sensitivity with 83% specificity for blaCTX-M-15. The complete ALADIM workflow was subsequently assessed using overnight positive blood cultures generated from 15 PCR-characterised strains, corresponding to 61 independent experiments encompassing sample preparation, DNA amplification, and LFIA readout. In this more challenging matrix, specificity remained above 77% for all targets. Sensitivity exceeded 94% for malF and blaOXA-48, whereas detection of blaCTX-M-15 showed lower sensitivity (56%). A comparable reduction in sensitivity was also observed with the reference in-tube method (>68%), underscoring the analytical challenges associated with direct analysis of blood culture-derived samples. Overall, this study demonstrates the feasibility of integrating sample preparation, multiplex nucleic acid amplification, microfluidic handling, and lateral-flow-based detection within a single user-friendly platform. While further optimization is required to improve performance in complex matrices, increase analytical sensitivity, and expand multiplexing capabilities, ALADIM provides a promising foundation for the development of accessible molecular diagnostics for bloodstream infections in low- and middle-income countries.","PeriodicalId":63,"journal":{"name":"Analyst","volume":"7 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2026-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d5an01310k","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Bacteraemia is a life-threatening infection associated with substantial morbidity and mortality. Current diagnosis relies on blood culture followed by culture-based identification and antimicrobial susceptibility testing, which remain the clinical gold standard but require prolonged turnaround times. Isothermal amplification technologies such as loop-mediated isothermal amplification (LAMP) offer a rapid, cost-effective, and accessible alternative for pathogen identification and antimicrobial resistance detection directly from positive blood cultures, particularly in resource-limited settings. However, their widespread implementation remains constrained by sample preparation requirements and limited multiplexing capabilities. To address these challenges, we developed ALADIM (Accessible and integrated LAMP Analysis for multiplex Detection of Infectious agents in Microfluidics), an integrated microfluidic platform combining bacterial DNA extraction, multiplex on-chip LAMP amplification, and instrument-free amplicon detection by lateral flow immunoassay (LFIA). The complete workflow can be performed in less than two hours, compared with the 24-48 h typically required for conventional diagnostic methods. As a proof of concept, the system was designed to detect E. coli, the most frequently reported pathogen in bacteraemia, together with two clinically relevant antimicrobial resistance determinants, blaCTX-M-15 and blaOXA-48, as well as an internal positive control. The multiplex assay was first evaluated using 14 bacterial strains cultured in LB medium. Performance of the on-chip workflow was comparable to that of the reference method consisting of conventional tube-based LAMP followed by LFIA detection, achieving 100% sensitivity and >84% specificity for malF and blaOXA-48, and 68% sensitivity with 83% specificity for blaCTX-M-15. The complete ALADIM workflow was subsequently assessed using overnight positive blood cultures generated from 15 PCR-characterised strains, corresponding to 61 independent experiments encompassing sample preparation, DNA amplification, and LFIA readout. In this more challenging matrix, specificity remained above 77% for all targets. Sensitivity exceeded 94% for malF and blaOXA-48, whereas detection of blaCTX-M-15 showed lower sensitivity (56%). A comparable reduction in sensitivity was also observed with the reference in-tube method (>68%), underscoring the analytical challenges associated with direct analysis of blood culture-derived samples. Overall, this study demonstrates the feasibility of integrating sample preparation, multiplex nucleic acid amplification, microfluidic handling, and lateral-flow-based detection within a single user-friendly platform. While further optimization is required to improve performance in complex matrices, increase analytical sensitivity, and expand multiplexing capabilities, ALADIM provides a promising foundation for the development of accessible molecular diagnostics for bloodstream infections in low- and middle-income countries.
用片上多路LAMP简化血培养菌血症的细菌鉴定和耐药性检测
菌血症是一种危及生命的感染,具有很高的发病率和死亡率。目前的诊断依赖于血液培养,然后是基于培养的鉴定和抗微生物药敏试验,这仍然是临床的金标准,但需要较长的周转时间。等温扩增技术,如环介导等温扩增(LAMP),为直接从阳性血液培养物中进行病原体鉴定和抗微生物药物耐药性检测提供了一种快速、经济、可及的替代方法,特别是在资源有限的环境中。然而,它们的广泛实施仍然受到样品制备要求和有限的多路复用能力的限制。为了解决这些挑战,我们开发了ALADIM(可访问和集成的LAMP分析用于微流体中感染因子的多重检测),这是一个集成的微流体平台,结合了细菌DNA提取,芯片上的多重LAMP扩增和通过侧流免疫测定(LFIA)的无仪器扩增子检测。与传统诊断方法通常需要24-48小时相比,整个工作流程可以在不到2小时内完成。作为概念验证,该系统被设计用于检测大肠杆菌,这是菌血症中最常见的病原体,以及两种临床相关的抗微生物药物耐药性决定因素,blaCTX-M-15和blaOXA-48,以及内部阳性对照。首先用LB培养基培养的14株细菌进行多重试验。片上工作流程的性能与参考方法相当,该方法由传统的管基LAMP和LFIA检测组成,对malF和blaOXA-48的灵敏度为100%,特异性为b> 84%,对blaCTX-M-15的灵敏度为68%,特异性为83%。随后,使用15株pcr特征菌株的隔夜阳性血培养物对完整的ALADIM工作流程进行评估,对应于61个独立实验,包括样品制备,DNA扩增和LFIA读数。在这个更具挑战性的基质中,所有靶标的特异性都保持在77%以上。malF和blaOXA-48的灵敏度超过94%,而blaCTX-M-15的灵敏度较低(56%)。参考管内法的灵敏度也有类似的降低(>68%),强调了直接分析血液培养源样品的分析挑战。总体而言,本研究证明了将样品制备、多重核酸扩增、微流体处理和基于侧流的检测集成在一个用户友好的平台中的可行性。虽然需要进一步优化以提高在复杂基质中的性能、提高分析灵敏度和扩展多路复用能力,但ALADIM为低收入和中等收入国家开发易于获得的血液感染分子诊断提供了有希望的基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: "Analyst" journal is the home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书