Variability of In-Body Absorbed Power Density at mmWave Frequencies

IF 4.5 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
IEEE journal of microwaves Pub Date : 2026-09-01 Epub Date: 2026-09-21 DOI:10.1109/JMW.2026.3726770
M. Mafamane;M. Ziane;G. Sacco;A. Boriskin;M. Zhadobov
{"title":"Variability of In-Body Absorbed Power Density at mmWave Frequencies","authors":"M. Mafamane;M. Ziane;G. Sacco;A. Boriskin;M. Zhadobov","doi":"10.1109/JMW.2026.3726770","DOIUrl":null,"url":null,"abstract":"In 5G and emerging 6G wireless networks, the operating frequencies are progressively expanding to the millimeter-wave (mmWave) range. At mmWave frequencies, the electromagnetic (EM) energy deposition is primarily confined to superficial skin layers. Dosimetric evaluation of human exposure requires accounting for anatomical variability and environmental conditions that influence the absorbed power density (<inline-formula><tex-math>$S_{\\text{ab}}$</tex-math></inline-formula>). This study investigates and quantifies the individual and combined effects of anatomical site, age, skin temperature, clothing, and hydration on <inline-formula><tex-math>$S_{\\text{ab}}$</tex-math></inline-formula> at <inline-formula><tex-math>$26 \\,\\mathrm{GHz}$</tex-math></inline-formula> and <inline-formula><tex-math>$60 \\,\\mathrm{GHz}$</tex-math></inline-formula>. Near-surface models of the head, ear, and palm are employed to evaluate the impact of site-specific structural and dielectric variations on <inline-formula><tex-math>$S_{\\text{ab}}$</tex-math></inline-formula>. The results demonstrate that the palm systematically exhibits the highest <inline-formula><tex-math>$S_{\\text{ab}}$</tex-math></inline-formula> due to the impedance-matching effect of its thick stratum corneum (SC), with multilayer models yielding increases up to <inline-formula><tex-math>$24 \\,\\%$</tex-math></inline-formula> at <inline-formula><tex-math>$26 \\,\\mathrm{GHz}$</tex-math></inline-formula> and <inline-formula><tex-math>$40 \\,\\%$</tex-math></inline-formula> at <inline-formula><tex-math>$60 \\,\\mathrm{GHz}$</tex-math></inline-formula> compared to homogeneous skin models. Age-related dielectric changes induce moderate <inline-formula><tex-math>$S_{\\text{ab}}$</tex-math></inline-formula> variations (up to <inline-formula><tex-math>$8 \\,\\%$</tex-math></inline-formula> at <inline-formula><tex-math>$26 \\,\\mathrm{GHz}$</tex-math></inline-formula> and <inline-formula><tex-math>$7 \\,\\%$</tex-math></inline-formula> at <inline-formula><tex-math>$60 \\,\\mathrm{GHz}$</tex-math></inline-formula>), while temperature variations lead to increases up to <inline-formula><tex-math>$7 \\,\\%$</tex-math></inline-formula> at <inline-formula><tex-math>$26 \\,\\mathrm{GHz}$</tex-math></inline-formula> and <inline-formula><tex-math>$10 \\,\\%$</tex-math></inline-formula> at <inline-formula><tex-math>$60 \\,\\mathrm{GHz}$</tex-math></inline-formula>, depending on the anatomical site. Clothing introduces the most pronounced effect. When the textile thickness satisfies a quarter-wavelength matching condition, <inline-formula><tex-math>$S_{\\text{ab}}$</tex-math></inline-formula> increases by up to <inline-formula><tex-math>$37 \\,\\%$</tex-math></inline-formula> at <inline-formula><tex-math>$26 \\,\\mathrm{GHz}$</tex-math></inline-formula> and <inline-formula><tex-math>$33 \\,\\%$</tex-math></inline-formula> at <inline-formula><tex-math>$60 \\,\\mathrm{GHz}$</tex-math></inline-formula> for the head and ear. When all parameters are jointly considered, the worst-case <inline-formula><tex-math>$S_{\\text{ab}}$</tex-math></inline-formula> enhancements reach <inline-formula><tex-math>$65 \\,\\%$</tex-math></inline-formula> at <inline-formula><tex-math>$26 \\,\\mathrm{GHz}$</tex-math></inline-formula> and <inline-formula><tex-math>$56 \\,\\%$</tex-math></inline-formula> at <inline-formula><tex-math>$60 \\,\\mathrm{GHz}$</tex-math></inline-formula> compared to the reference case (adult, dry skin at 33 <inline-formula><tex-math>$^{\\circ }$</tex-math></inline-formula>C). Skin hydration further impacts <inline-formula><tex-math>$S_{\\text{ab}}$</tex-math></inline-formula>: at <inline-formula><tex-math>$26 \\,\\mathrm{GHz}$</tex-math></inline-formula>, <inline-formula><tex-math>$S_{\\text{ab}}$</tex-math></inline-formula> increases by up to <inline-formula><tex-math>$26 \\,\\%$</tex-math></inline-formula> in the ear and <inline-formula><tex-math>$8 \\,\\%$</tex-math></inline-formula> in the head, whereas at <inline-formula><tex-math>$60 \\,\\mathrm{GHz}$</tex-math></inline-formula> the influence remains negligible in the ear and head (regions with a thin SC). In contrast, for the palm, skin hydration attenuates <inline-formula><tex-math>$S_{\\text{ab}}$</tex-math></inline-formula> at both frequencies. These findings demonstrate that anatomical site and textile-induced impedance matching dominate mmWave exposure variability (up to <inline-formula><tex-math>$37 \\,\\%$</tex-math></inline-formula>), while age and temperature introduce less pronounced effects (up to <inline-formula><tex-math>$10 \\,\\%$</tex-math></inline-formula>).","PeriodicalId":93296,"journal":{"name":"IEEE journal of microwaves","volume":"6 5","pages":"1160-1173"},"PeriodicalIF":4.5000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11700401","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE journal of microwaves","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11700401/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/21 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

In 5G and emerging 6G wireless networks, the operating frequencies are progressively expanding to the millimeter-wave (mmWave) range. At mmWave frequencies, the electromagnetic (EM) energy deposition is primarily confined to superficial skin layers. Dosimetric evaluation of human exposure requires accounting for anatomical variability and environmental conditions that influence the absorbed power density ($S_{\text{ab}}$). This study investigates and quantifies the individual and combined effects of anatomical site, age, skin temperature, clothing, and hydration on $S_{\text{ab}}$ at $26 \,\mathrm{GHz}$ and $60 \,\mathrm{GHz}$. Near-surface models of the head, ear, and palm are employed to evaluate the impact of site-specific structural and dielectric variations on $S_{\text{ab}}$. The results demonstrate that the palm systematically exhibits the highest $S_{\text{ab}}$ due to the impedance-matching effect of its thick stratum corneum (SC), with multilayer models yielding increases up to $24 \,\%$ at $26 \,\mathrm{GHz}$ and $40 \,\%$ at $60 \,\mathrm{GHz}$ compared to homogeneous skin models. Age-related dielectric changes induce moderate $S_{\text{ab}}$ variations (up to $8 \,\%$ at $26 \,\mathrm{GHz}$ and $7 \,\%$ at $60 \,\mathrm{GHz}$), while temperature variations lead to increases up to $7 \,\%$ at $26 \,\mathrm{GHz}$ and $10 \,\%$ at $60 \,\mathrm{GHz}$, depending on the anatomical site. Clothing introduces the most pronounced effect. When the textile thickness satisfies a quarter-wavelength matching condition, $S_{\text{ab}}$ increases by up to $37 \,\%$ at $26 \,\mathrm{GHz}$ and $33 \,\%$ at $60 \,\mathrm{GHz}$ for the head and ear. When all parameters are jointly considered, the worst-case $S_{\text{ab}}$ enhancements reach $65 \,\%$ at $26 \,\mathrm{GHz}$ and $56 \,\%$ at $60 \,\mathrm{GHz}$ compared to the reference case (adult, dry skin at 33 $^{\circ }$C). Skin hydration further impacts $S_{\text{ab}}$: at $26 \,\mathrm{GHz}$, $S_{\text{ab}}$ increases by up to $26 \,\%$ in the ear and $8 \,\%$ in the head, whereas at $60 \,\mathrm{GHz}$ the influence remains negligible in the ear and head (regions with a thin SC). In contrast, for the palm, skin hydration attenuates $S_{\text{ab}}$ at both frequencies. These findings demonstrate that anatomical site and textile-induced impedance matching dominate mmWave exposure variability (up to $37 \,\%$), while age and temperature introduce less pronounced effects (up to $10 \,\%$).
毫米波频率下体内吸收功率密度的变异性
在5G和新兴的6G无线网络中,工作频率正在逐步扩展到毫米波(mmWave)范围。在毫米波频率下,电磁(EM)能量沉积主要局限于皮肤表层。人体暴露的剂量学评估需要考虑影响吸收功率密度的解剖变异和环境条件($S_{\text{ab}}$)。本研究调查并量化了解剖部位、年龄、皮肤温度、服装和水合作用对$S_{\text{ab}}$在$26 \,\ mathm {GHz}$和$60 \,mathm {GHz}$的个体和综合影响。使用头部、耳朵和手掌的近表面模型来评估特定部位结构和介电变化对$S_{\text{ab}}$的影响。结果表明,由于其厚角质层(SC)的阻抗匹配效应,手掌系统地表现出最高的$S_{\text{ab}}$,多层模型的产量与均匀皮肤模型相比增加了$24 \,$26 \,$ mathm {GHz}$和$40 \,$60 \,$ mathm {GHz}$。年龄相关的介电变化导致中等的$S_{\text{ab}}$变化(高达$8 \,$26 \,$ mathm {GHz}$和$7 \,$60 \,$ mathm {GHz}$),而温度变化导致高达$7 \,$26 \,$ mathm {GHz}$和$10 \,$60 \,$ mathm {GHz}$,这取决于解剖部位。服装带来的影响最为明显。当织物厚度满足四分之一波长匹配条件时,$S_{\text{ab}}$最多增加$37 \,$26 \、$ mathm {GHz}$和$33 \,$60 \、$ mathm {GHz}$为头部和耳朵增加$ %$。当共同考虑所有参数时,与参考情况(成人,干燥皮肤在33 $^{\circ}$C)相比,最坏情况下的$S_{\text{ab}}$增强达到$65 \,$ %$在$26 \,$ mathm {GHz}$和$56 \,$60 \,$ mathm {GHz}$)。皮肤水合作用进一步影响$S_{\text{ab}}$: $S_{\text{ab}}$在$26 \,$ mathm {GHz}$时,$S_{\text{ab}}$在耳朵增加高达$26 \,%$,$8 \,%$,而在$60 \,$ mathm {GHz}$时,对耳朵和头部(具有薄SC的区域)的影响仍然可以忽略。相反,对于手掌,皮肤水合作用在两个频率下都减弱。这些发现表明,解剖部位和纺织品引起的阻抗匹配主导毫米波暴露变异性(高达$37 \,\%$),而年龄和温度引入的影响不太明显(高达$10 \,\%$)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.70
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书