Axial Length to Corneal Curvature Ratio is Insufficient for Detecting Pseudomyopia in Children: A Multi-Cohort Study.

IF 2.4
Huyen T Bui, Dirk J van Hemert, Tianli Peng, Shuhui Yang, Hai-Yen T Nguyen, Hannah Noor, Siofra C Harrington, Sander C M Kneepkens, Lene A Hagen, Craig S Walker, Edward Mallen, Matthew Cufflin, Rigmor C Baraas, Neema Ghorbani-Mojarrad, Olavi Pärssinen, Louise Terry, Shi-Ming Li, Amanda N French, Jason C Yam, Caroline C W Klaver, Jeremy A Guggenheim
{"title":"Axial Length to Corneal Curvature Ratio is Insufficient for Detecting Pseudomyopia in Children: A Multi-Cohort Study.","authors":"Huyen T Bui, Dirk J van Hemert, Tianli Peng, Shuhui Yang, Hai-Yen T Nguyen, Hannah Noor, Siofra C Harrington, Sander C M Kneepkens, Lene A Hagen, Craig S Walker, Edward Mallen, Matthew Cufflin, Rigmor C Baraas, Neema Ghorbani-Mojarrad, Olavi Pärssinen, Louise Terry, Shi-Ming Li, Amanda N French, Jason C Yam, Caroline C W Klaver, Jeremy A Guggenheim","doi":"10.1007/s44402-026-00185-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Pseudomyopia is an accommodative disorder that can be identified by the difference between pre- and post-cycloplegic refractive error. The current study aimed to evaluate whether the axial length to corneal curvature (AL/CR) ratio, in conjunction with non-cycloplegic refractive error, can reliably identify pseudomyopia in children, thus avoiding the need for cycloplegia.</p><p><strong>Methods: </strong>Refractive error and biometry data from longitudinal studies based in Denmark (n = 645; age 7-17 years) and China (Anyang Childhood Eye Study; n = 2487; age 6-13 years) were used to train separate linear mixed models for children of European or East Asian ancestry, respectively, with AL/CR ratio as outcome and cycloplegic spherical equivalent refractive error (SER), age and sex as predictors. The models could be used to calculate the AL/CR 95% prediction interval in a child of known age, sex and non-cycloplegic SER; if the child's AL/CR fell below the lower limit of the AL/CR 95% prediction interval, then the child was classified as pseudomyopic. The European and East Asian models were externally validated using data from participants of the Ireland Eye Study (IES; n = 92) and Sydney Myopia Study (SMS; n = 686) cohorts, and the Hong Kong Children Eye Study (HKCES; n = 9519) and Vietnam (n = 1165) cohorts, respectively.</p><p><strong>Results: </strong>The European model demonstrated moderate detection accuracy for pseudomyopia: sensitivity = 0.82 (IES) and 0.81 (SMS); specificity = 0.75 in both cohorts. By contrast, the East Asian model performed poorly: sensitivity = 0.22 (HKCES) and 0.13 (Vietnam); specificity = 0.99 in both cohorts.</p><p><strong>Conclusions: </strong>Despite moderate diagnostic performance in European samples, the current AL/CR-based models lacked sufficient accuracy for screening and performed poorly in East Asian children, suggesting that AL/CR is not a reliable non-cycloplegic marker of pseudomyopia. Further studies incorporating additional ocular biometric parameters and employing a more rigorous definition of pseudomyopia may build on these initial findings.</p>","PeriodicalId":520731,"journal":{"name":"Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s44402-026-00185-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Pseudomyopia is an accommodative disorder that can be identified by the difference between pre- and post-cycloplegic refractive error. The current study aimed to evaluate whether the axial length to corneal curvature (AL/CR) ratio, in conjunction with non-cycloplegic refractive error, can reliably identify pseudomyopia in children, thus avoiding the need for cycloplegia.

Methods: Refractive error and biometry data from longitudinal studies based in Denmark (n = 645; age 7-17 years) and China (Anyang Childhood Eye Study; n = 2487; age 6-13 years) were used to train separate linear mixed models for children of European or East Asian ancestry, respectively, with AL/CR ratio as outcome and cycloplegic spherical equivalent refractive error (SER), age and sex as predictors. The models could be used to calculate the AL/CR 95% prediction interval in a child of known age, sex and non-cycloplegic SER; if the child's AL/CR fell below the lower limit of the AL/CR 95% prediction interval, then the child was classified as pseudomyopic. The European and East Asian models were externally validated using data from participants of the Ireland Eye Study (IES; n = 92) and Sydney Myopia Study (SMS; n = 686) cohorts, and the Hong Kong Children Eye Study (HKCES; n = 9519) and Vietnam (n = 1165) cohorts, respectively.

Results: The European model demonstrated moderate detection accuracy for pseudomyopia: sensitivity = 0.82 (IES) and 0.81 (SMS); specificity = 0.75 in both cohorts. By contrast, the East Asian model performed poorly: sensitivity = 0.22 (HKCES) and 0.13 (Vietnam); specificity = 0.99 in both cohorts.

Conclusions: Despite moderate diagnostic performance in European samples, the current AL/CR-based models lacked sufficient accuracy for screening and performed poorly in East Asian children, suggesting that AL/CR is not a reliable non-cycloplegic marker of pseudomyopia. Further studies incorporating additional ocular biometric parameters and employing a more rigorous definition of pseudomyopia may build on these initial findings.

眼轴长度与角膜曲率比不足以检测儿童假性近视:一项多队列研究。
目的:假性近视是一种适应性疾病,可以通过睫状体麻痹前后屈光不正的差异来识别。本研究旨在评估轴长与角膜曲率(AL/CR)比值,结合非独眼性屈光不正,是否可以可靠地识别儿童假性近视,从而避免独眼性屈光不正的需要。方法:使用来自丹麦(n = 645,年龄7-17岁)和中国(安阳儿童眼科研究,n = 2487,年龄6-13岁)的纵向研究的屈光不正和生物测量数据,分别训练欧洲或东亚血统儿童的单独线性混合模型,以AL/CR比率为结果,并以睫状体麻痹的球等效屈光不正(SER)、年龄和性别为预测因子。该模型可用于计算已知年龄、性别和非独眼性SER患儿的AL/CR 95%预测区间;如果患儿的AL/CR低于AL/CR 95%预测区间的下限,则判定患儿为假性近视。欧洲和东亚模型分别使用爱尔兰眼科研究(IES, n = 92)和悉尼近视研究(SMS, n = 686)队列、香港儿童眼科研究(HKCES, n = 9519)和越南(n = 1165)队列参与者的数据进行外部验证。结果:欧洲模型对假性近视的检测准确率中等:灵敏度= 0.82 (IES)和0.81 (SMS);两个队列的特异性均为0.75。相比之下,东亚模型表现不佳:敏感性= 0.22(香港)和0.13(越南);两个队列的特异性均为0.99。结论:尽管在欧洲样本中具有中等的诊断性能,但目前基于AL/CR的模型在筛查中缺乏足够的准确性,在东亚儿童中表现不佳,这表明AL/CR并不是一个可靠的假性近视非独眼性标志。在这些初步发现的基础上,进一步的研究可能会纳入更多的眼部生物特征参数,并采用更严格的假性近视定义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书