Anatomical fit of a precontoured suprapectineal plate in japanese patients with acetabular fractures: A three-dimensional morphometric study

IF 2.4 3区 医学 Q3 CRITICAL CARE MEDICINE
Masahiro Yoshida, Mitsunaga Iwata, Nobunori Takahashi
{"title":"Anatomical fit of a precontoured suprapectineal plate in japanese patients with acetabular fractures: A three-dimensional morphometric study","authors":"Masahiro Yoshida,&nbsp;Mitsunaga Iwata,&nbsp;Nobunori Takahashi","doi":"10.1016/j.injury.2026.113709","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Anatomically precontoured suprapectineal plates have been developed to reduce intraoperative contouring and facilitate anatomical fixation of acetabular fractures. However, their fit to the pelvic morphology of Japanese patients remains inadequately investigated. We aimed to evaluate the anatomical fit of a commercially available precontoured suprapectineal plate using mirrored three-dimensional (3D) pelvic models reconstructed from computed tomography (CT) images.</div></div><div><h3>Methods</h3><div>This retrospective morphometric study included 12 consecutive Japanese patients with acetabular fractures (nine men and three women; mean age, 73.5 years). Thin-slice CT images (1–2 mm) were reconstructed into patient-specific 3D pelvic models using ZedView software. The intact contralateral hemipelvis was mirrored to create an anatomical model. The mirrored models were exported as stereolithography (STL) files, processed using Z-SUITE software, and fabricated at full scale (1:1) using a Zortrax® fused deposition modeling 3D printer with acrylonitrile butadiene styrene (ABS) filament. A commercially available precontoured suprapectineal anatomical plate was placed on each mirrored pelvic model without additional contouring. Plate fit, iliopectineal line length, and pelvic curvature were evaluated. Poor fit was defined as a gap &gt; 5 mm between the plate and bone surface. Plate fit and morphometric measurements were performed by a single orthopedic surgeon according to predefined criteria. Correlations between anthropometric parameters and pelvic morphology were analyzed using Pearson's correlation coefficient. Statistical significance was set at p &lt; 0.05.</div></div><div><h3>Results</h3><div>Poor plate fit was identified in eight of 12 patients (66.7%). In four patients (33.3%), the anterior portion of the plate overhung the pubic symphysis despite appropriate positioning along the pelvic brim. Iliopectineal line length was positively correlated with body height (r = 0.628, p = 0.029) and body weight (r = 0.610, p = 0.035), but not pelvic curvature (r = 0.385, p = 0.216).</div></div><div><h3>Conclusions</h3><div>The precontoured suprapectineal anatomical plate frequently showed inadequate anterior conformity in Japanese patients with acetabular fractures. Preoperative patient-specific evaluation using mirrored 3D pelvic models may facilitate implant selection and surgical planning while providing valuable information for future anatomical plate design.</div></div>","PeriodicalId":54978,"journal":{"name":"Injury-International Journal of the Care of the Injured","volume":"57 10","pages":"Article 113709"},"PeriodicalIF":2.4000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Injury-International Journal of the Care of the Injured","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0020138326006960","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Anatomically precontoured suprapectineal plates have been developed to reduce intraoperative contouring and facilitate anatomical fixation of acetabular fractures. However, their fit to the pelvic morphology of Japanese patients remains inadequately investigated. We aimed to evaluate the anatomical fit of a commercially available precontoured suprapectineal plate using mirrored three-dimensional (3D) pelvic models reconstructed from computed tomography (CT) images.

Methods

This retrospective morphometric study included 12 consecutive Japanese patients with acetabular fractures (nine men and three women; mean age, 73.5 years). Thin-slice CT images (1–2 mm) were reconstructed into patient-specific 3D pelvic models using ZedView software. The intact contralateral hemipelvis was mirrored to create an anatomical model. The mirrored models were exported as stereolithography (STL) files, processed using Z-SUITE software, and fabricated at full scale (1:1) using a Zortrax® fused deposition modeling 3D printer with acrylonitrile butadiene styrene (ABS) filament. A commercially available precontoured suprapectineal anatomical plate was placed on each mirrored pelvic model without additional contouring. Plate fit, iliopectineal line length, and pelvic curvature were evaluated. Poor fit was defined as a gap > 5 mm between the plate and bone surface. Plate fit and morphometric measurements were performed by a single orthopedic surgeon according to predefined criteria. Correlations between anthropometric parameters and pelvic morphology were analyzed using Pearson's correlation coefficient. Statistical significance was set at p < 0.05.

Results

Poor plate fit was identified in eight of 12 patients (66.7%). In four patients (33.3%), the anterior portion of the plate overhung the pubic symphysis despite appropriate positioning along the pelvic brim. Iliopectineal line length was positively correlated with body height (r = 0.628, p = 0.029) and body weight (r = 0.610, p = 0.035), but not pelvic curvature (r = 0.385, p = 0.216).

Conclusions

The precontoured suprapectineal anatomical plate frequently showed inadequate anterior conformity in Japanese patients with acetabular fractures. Preoperative patient-specific evaluation using mirrored 3D pelvic models may facilitate implant selection and surgical planning while providing valuable information for future anatomical plate design.
日本髋臼骨折患者预轮廓的阴部上钢板的解剖配合:三维形态计量学研究。
背景:解剖预轮廓的耻骨上钢板已被开发用于减少术中轮廓和促进髋臼骨折的解剖固定。然而,它们与日本患者盆腔形态的契合度仍未得到充分的研究。我们的目的是利用计算机断层扫描(CT)图像重建的镜像三维(3D)骨盆模型来评估市售的预轮廓阴部上钢板的解剖配合度。方法:这项回顾性形态计量学研究纳入了12例连续的日本髋臼骨折患者(9男3女,平均年龄73.5岁)。利用ZedView软件将薄层CT图像(1 ~ 2 mm)重建为患者特异性三维骨盆模型。完整的对侧半骨盆镜像创建解剖模型。镜像模型导出为立体光版(STL)文件,使用Z-SUITE软件进行处理,并使用带有丙烯腈-丁二烯-苯乙烯(ABS)长丝的Zortrax®熔融沉积建模3D打印机以全尺寸(1:1)制作。一个市售的预轮廓的阴蒂上解剖板放置在每个镜像盆腔模型上,没有额外的轮廓。评估钢板配合度、髂耻线长度和骨盆曲度。配合不良定义为钢板与骨表面之间的间隙> 5 mm。钢板贴合和形态测量由一名骨科医生根据预先确定的标准进行。使用Pearson相关系数分析人体测量参数与骨盆形态的相关性。结果:12例患者中有8例(66.7%)钢板配合不良。在4例(33.3%)患者中,尽管沿骨盆边缘放置合适,但钢板前部仍悬于耻骨联合上方。胯栉线长度呈正相关,身体高度(r = 0.628,p = 0.029)和体重(r = 0.610,p = 0.035),但不是盆腔曲率(r = 0.385,p = 0.216)。结论:在日本髋臼骨折患者中,预轮廓的阴部上解剖钢板经常出现前一致性不足的情况。术前使用镜像三维骨盆模型进行患者特异性评估有助于植入物的选择和手术计划,同时为未来解剖钢板的设计提供有价值的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.00
自引率
8.00%
发文量
699
审稿时长
96 days
期刊介绍: Injury was founded in 1969 and is an international journal dealing with all aspects of trauma care and accident surgery. Our primary aim is to facilitate the exchange of ideas, techniques and information among all members of the trauma team.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书