Real-Time AI-Assisted Detection of Colonic Lesions Using the iIDEAS Intelligent-C Module: A Prospective Single-Center Validation Study

IF 1.6 Q3 GASTROENTEROLOGY & HEPATOLOGY
JGH Open Pub Date : 2026-09-17 DOI:10.1002/jgh3.70470
Hardik Rughwani, Rajat Garg, Sana Fathima Memon, Chung Kwong Yeung, Biji Sreedhar, Kwun Ping Lai, Rajendra Patel, Nitin Jagtap, Syed Jameel Hussain, Mohammed Sanny, Rakesh Kalapala, D. Nageshwar Reddy
{"title":"Real-Time AI-Assisted Detection of Colonic Lesions Using the iIDEAS Intelligent-C Module: A Prospective Single-Center Validation Study","authors":"Hardik Rughwani,&nbsp;Rajat Garg,&nbsp;Sana Fathima Memon,&nbsp;Chung Kwong Yeung,&nbsp;Biji Sreedhar,&nbsp;Kwun Ping Lai,&nbsp;Rajendra Patel,&nbsp;Nitin Jagtap,&nbsp;Syed Jameel Hussain,&nbsp;Mohammed Sanny,&nbsp;Rakesh Kalapala,&nbsp;D. Nageshwar Reddy","doi":"10.1002/jgh3.70470","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Aims</h3>\n \n <p>Colorectal cancer (CRC) remains a major cause of cancer mortality, with up to 26% of adenomas missed on conventional colonoscopy. Artificial intelligence (AI)–based computer-aided detection (CADe) systems may reduce these miss rates. We aimed to validate the iIDEAS-C CADe module in a prospective cohort, with co-primary endpoints of adenomas per colonoscopy (APC) and lesion-level miss rate.</p>\n </section>\n \n <section>\n \n <h3> Methods and Results</h3>\n \n <p>In this prospective, nonrandomized, single-center study (NCT05784935), consecutive adults (18–75 years) undergoing screening, surveillance, or diagnostic colonoscopy were enrolled between February and May 2023. Each colon segment was inspected twice: an initial blinded withdrawal without CADe, followed by a second inspection with iIDEAS-C. Missed lesions were those identified by CADe during the second inspection and confirmed endoscopically. Secondary outcomes included PDR, ADR, PPC, lesion characteristics, and procedural times.</p>\n \n <p>Two hundred patients (mean age 44.1 ± 12.7 years; 64% male) were included. Eighty-two polyps were detected across 42 patients (PDR = 21%). Endoscopists detected 61/82 polyps (74.4%), yielding a per-polyp miss rate of 25.6%. The iIDEAS-C module detected all 82 lesions, achieving 0% per-polyp and per-adenoma miss rate. Missed lesions were mostly diminutive and proximal. PPC increased from 0.305 to 0.410 (<i>p</i> &lt; 0.0001), PDR from 17.5% to 21.0% (<i>p</i> = 0.016), and APC from 0.115 to 0.140 (<i>p</i> = 0.029). No adverse events occurred.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The iIDEAS-C module demonstrated a 0% lesion-level miss rate and significantly improved key detection metrics, especially for small proximal lesions. Larger multicenter studies are warranted to confirm these findings and assess long-term outcomes. ClinicalTrials.gov: NCT05784935.</p>\n \n <p><b>Trial Registration:</b> ClinicalTrials.gov identifier: NCT05784935.</p>\n </section>\n </div>","PeriodicalId":45861,"journal":{"name":"JGH Open","volume":"10 9","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2026-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jgh3.70470","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JGH Open","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jgh3.70470","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Aims

Colorectal cancer (CRC) remains a major cause of cancer mortality, with up to 26% of adenomas missed on conventional colonoscopy. Artificial intelligence (AI)–based computer-aided detection (CADe) systems may reduce these miss rates. We aimed to validate the iIDEAS-C CADe module in a prospective cohort, with co-primary endpoints of adenomas per colonoscopy (APC) and lesion-level miss rate.

Methods and Results

In this prospective, nonrandomized, single-center study (NCT05784935), consecutive adults (18–75 years) undergoing screening, surveillance, or diagnostic colonoscopy were enrolled between February and May 2023. Each colon segment was inspected twice: an initial blinded withdrawal without CADe, followed by a second inspection with iIDEAS-C. Missed lesions were those identified by CADe during the second inspection and confirmed endoscopically. Secondary outcomes included PDR, ADR, PPC, lesion characteristics, and procedural times.

Two hundred patients (mean age 44.1 ± 12.7 years; 64% male) were included. Eighty-two polyps were detected across 42 patients (PDR = 21%). Endoscopists detected 61/82 polyps (74.4%), yielding a per-polyp miss rate of 25.6%. The iIDEAS-C module detected all 82 lesions, achieving 0% per-polyp and per-adenoma miss rate. Missed lesions were mostly diminutive and proximal. PPC increased from 0.305 to 0.410 (p < 0.0001), PDR from 17.5% to 21.0% (p = 0.016), and APC from 0.115 to 0.140 (p = 0.029). No adverse events occurred.

Conclusion

The iIDEAS-C module demonstrated a 0% lesion-level miss rate and significantly improved key detection metrics, especially for small proximal lesions. Larger multicenter studies are warranted to confirm these findings and assess long-term outcomes. ClinicalTrials.gov: NCT05784935.

Trial Registration: ClinicalTrials.gov identifier: NCT05784935.

使用iIDEAS智能c模块实时人工智能辅助检测结肠病变:一项前瞻性单中心验证研究
结直肠癌(CRC)仍然是癌症死亡的主要原因,高达26%的腺瘤在常规结肠镜检查中漏诊。基于人工智能(AI)的计算机辅助检测(CADe)系统可能会降低这些失检率。我们的目的是在一个前瞻性队列中验证iIDEAS-C CADe模块,其共同主要终点是每次结肠镜检查的腺瘤(APC)和病变水平的遗漏率。方法和结果在这项前瞻性、非随机、单中心研究(NCT05784935)中,在2023年2月至5月期间招募了接受筛查、监测或诊断性结肠镜检查的连续成年人(18-75岁)。每个结肠段检查两次:首次无CADe盲法停药,随后用iIDEAS-C进行第二次检查。漏诊病灶是指那些在第二次检查中被CADe发现并经内镜确认的病灶。次要结局包括PDR、ADR、PPC、病变特征和手术时间。纳入200例患者(平均年龄44.1±12.7岁,男性占64%)。42例患者共检出82个息肉(PDR = 21%)。内镜检查出61/82个息肉(74.4%),每个息肉的漏检率为25.6%。iIDEAS-C模块检测了所有82个病变,每个息肉和每个腺瘤的漏报率为0%。遗漏的病变大多是小的和近端的。PPC从0.305增加到0.410 (p < 0.0001), PDR从17.5%增加到21.0% (p = 0.016), APC从0.115增加到0.140 (p = 0.029)。无不良事件发生。结论iIDEAS-C模块的病变水平缺失率为0%,关键检测指标显著提高,尤其是对近端小病变。需要更大规模的多中心研究来证实这些发现并评估长期结果。ClinicalTrials.gov: NCT05784935。试验注册:ClinicalTrials.gov标识符:NCT05784935。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JGH Open
JGH Open GASTROENTEROLOGY & HEPATOLOGY-
CiteScore
3.40
自引率
0.00%
发文量
143
审稿时长
7 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书